VIOX ELECTRIC
Język

VIOX VSP-X15 / VSP-X30 / VSP-X50 Graphite Spark-Gap AC Type 1 Lightning Arrester

The VIOX VSP-X15, VSP-X30, and VSP-X50 are encapsulated multi-layer graphite spark-gap AC Type 1 lightning current arresters engineered for direct lightning strike protection (Iimp 15 kA, 30 kA, and 50 kA at 10/350 μs). Featuring zero leakage current, 50 kA follow-current extinguishing capability (Ifi), and 50 kA short-circuit withstand, they are built for heavy industrial substations and telecom main incoming switchboards.

Seria VIOX
VSP-X15 / VSP-X30 / VSP-X50
Napięcie znamionowe
AC 275V / 320V / 385V / 440V
Surge Rating
Iimp 15 / 30 / 50 kA (10/350μs)
Standard
IEC 61643-11 · Type 1 · 50kA Ifi

Przegląd

The VIOX VSP-X15, VSP-X30, and VSP-X50 are encapsulated multi-layer graphite spark-gap AC Type 1 lightning current arresters engineered for direct lightning strike protection (Iimp 15 kA, 30 kA, and 50 kA at 10/350 μs). Featuring zero leakage current, 50 kA follow-current extinguishing capability (Ifi), and 50 kA short-circuit withstand, they are built for heavy industrial substations and telecom main incoming switchboards.

Cechy

  • Multi-layer encapsulated graphite spark-gap technology handles extreme 15 kA, 30 kA, and 50 kA (10/350 μs) direct lightning currents.
  • High 50 kA follow-current interrupt rating (Ifi) and 50,000 A short-circuit rating (Isccr) with zero standby leakage (Ipe = NONE).
  • Constant Up 2.5 kV clamping level across Uc 275 V, 320 V, 385 V, and 440 V AC systems.
  • No blowout arc emission — safely mounts inside compact metal distribution panels on a standard 35 mm DIN rail.

Specyfikacje

VSP-X15 / VSP-X30 / VSP-X50 Electrical & Mechanical Specifications

ParametrSpecyfikacja
SPD ClassificationType 1 (Class I) Graphite Spark-Gap · IEC 61643-11
Max Continuous Operating Voltage (Uc)275 V / 320 V / 385 V / 440 V AC
Lightning Impulse Current (Iimp, 10/350 μs)VSP-X15: 15 kA · VSP-X30: 30 kA · VSP-X50: 50 kA
Poziom ochrony napięciowej (Up)2.5 kV (L-N & N-PE) · Response Time: ≤100 ns
Follow Current Interrupt Rating (Ifi)50 kA · Isccr: 50,000 A · Leakage Ipe: NONE
Recommended Backup SCBVIOX VSP-SSD50X
Terminals & Housing6–35 mm² (2.5 N·m) · PBT/PA UL94 V-0 · IP20 · 35 mm DIN rail

VSP-X15 / VSP-X30 / VSP-X50 Available Poles & Dimensions

Polak1P1+NPE / 2P3P4P / 3+NPE
Dimensions (W × H × D)36 × 90 × 68 mm72 × 90 × 68 mm108 × 90 × 68 mm144 × 90 × 68 mm

Wymiary i instalacja

VIOX VSP-X15 / VSP-X30 / VSP-X50 Graphite Spark-Gap AC Type 1 Lightning Arrester Dimensional Drawing (mm)
VSP-X15 / VSP-X30 / VSP-X50 Outline & DIN-Rail Mounting Dimensions (unit: mm)
  • Install at LPZ 0A → LPZ 1 main incoming switchgear where maximum 50 kA (10/350 μs) lightning current capacity is mandated.
  • Coordinate downstream with VIOX VSP-40 Type 2 SPD for sensitive equipment requiring Up ≤1.5 kV.
  • Explore the complete VIOX Surge Protection Devices (SPD) catalog for matched AC, Solar PV DC, and SCB backup protection.

FAQ

What is the benefit of a graphite spark-gap Type 1 SPD over an MOV-only SPD?

Encapsulated graphite spark gaps withstand massive 50 kA (10/350 μs) direct lightning energy with zero standby leakage current and virtually no thermal aging over decades of service.

Potrzebujesz wyceny produktu?
Zbudujmy to razem.

Prześlij nam model produktu, parametry techniczne, ilość oraz wymagania OEM. Nasz zespół przeanalizuje Twoje zgłoszenie i odpowie w ciągu jednego dnia roboczego.

Zapytanie ofertowe