VIOX ELECTRIC
Język
Direct DIN-Rail & Switchgear Manufacturer

Voltage Protector Manufacturer DIN-Rail 1P, 3P SYN/ASY, Auto Phase Selectors & WiFi Smart Relays (16A–125A)

Engineered for unstable grids, commercial distribution panels, motors, and OEM switchboards. VIOX builds 22 load-carrying adjustable voltage, current, leakage & kWh protectors with magnetic latching relays (≥100,000 cycles) alongside 2 control-circuit monitoring relays.

24 VIOX Series22 load protectors + 2 control relays
16A – 125A Direct LoadMagnetic latching relays (≥100k cycles)
AC 140–300V / 3×380V1P, 3P SYN/ASY, Phase Selector & WiFi
VIOX VOPD1-63VAE Single-Phase Adjustable Voltage, Current & kWh Protector (40A / 63A)
01 · Platform Architecture

Six VIOX Voltage Protection Architectures

Compare supply topology, load current capability, wiring polarity, and relay type across our complete voltage protection portfolio.

VIOX Voltage Protector & Monitoring Relay Architecture Comparison (24 Series)
Series Family VIOX Models Supply & Current Zakres ochrony Wiring Direction Główne zastosowanie
Single-Phase DIN-Rail (8) VOPD1-63VAE, VOPD1-60-EC/63VA, VOPD1-63DK, VOPD1-40M, VOD238-VAP, VOPD1-60/60-V/63VAE-Z AC 140–300V · 1P+N · 40A / 63A / 80A OV, UV, OC, kWh / Prepaid, Over-Power kW, Dual-Pole L+N Top-IN / Bottom-OUT (18mm & 36mm DIN) Residential panels, commercial sub-boards, HVAC & sub-metering
Three-Phase DIN-Rail (4) VOPD3-63VA/100VA, VOPD3-63VAS/100VAS, VOPD3-60/125, VOPD3-II 3×220/380V AC · 3P / 3P+N · 63A / 100A / 125A Per-phase OV/UV/OC, Phase Loss, Unbalance, Sequence, SYN/ASY Mode VOPD3-VA: Bottom-IN / Top-OUT (check label) 3-phase motors, industrial pumps, compressors, commercial risers
Auto Phase Selectors (4) VOPD3-63VAYA/100VAYA, VOPD3-63VAY/100VAY, VOPD3-63VAEY, VOAP2-100A 3×220V In → 1×220V Out · 63A / 100A Auto-transfer to healthy phase on OV/UV/outage, priority return, prepaid kWh 3-Phase Input (L1/L2/L3+N) → 1-Phase Load Telecom racks, clinics, servers & critical 1P loads on 3P supply
WiFi Tuya Smart (3) VOMPD-63LW, VOB9S-VAP (18mm), VOVA-63T (Color LCD) AC 85–300V · 1P+N (L+N only) · 63A Tuya WiFi App control, OV/UV/OC, kWh, 10–99mA Leakage (63LW/63T) Top-IN / Bottom-OUT (strictly L+N, never L+L) Remote rental management, solar inverters, smart distribution boards
Leakage / RTC & Plug-In (3) VOMPD-63SL, VOMPD-63L-BAT (RTC), VOSVA-16 (EU Plug-In) AC 140–300V · 16A Plug-In / 63A DIN 10–99mA earth leakage, RTC battery timer, appliance-level OV/UV/OC DIN Top-IN / Bottom-OUT · VOSVA-16 Direct EU Socket Refrigerators, retail freezers, timed lighting & shock-sensitive circuits
Control Monitoring Relays (2) VOMPD-8S (3-Phase 6A), VOMPD-AD220 (AC/DC 6A) 3×380V AC / AC-DC 24–220V · 6A Control Voltage window, phase sequence & asymmetry via 1CO dry contact 18mm Control Relay → Drives External AC Contactor MCC cabinets, ATS panels, cranes, industrial machinery >100A
02 · Complete Product Lineup

24 VIOX Voltage Protectors & Monitoring Relays

Filter by phase architecture or smart capability. Click any series card for full programmable menu codes (A0–A18 / P1–C5) and wiring instructions.

03 · Engineering Sizing Tool

Interactive Voltage Protector Selector

Select your grid topology and required protection features to match the exact VIOX model, wiring polarity, and menu architecture.

Step 1 · Select Supply Topology & Duty

Step 2 · Select Feature & Current Tier

04 · Panel Wiring & Field Reliability

Wiring Polarity & 4 Common Commissioning Mistakes

Verify terminal feed direction before commissioning DIN-rail voltage protectors to prevent relay damage and nuisance trips.

A · SINGLE-PHASE TOP-IN / BOTTOM-OUT VOPD1-63VAE · VOPD1-60-EC · VOMPD-63LW · VOB9S-VAP L IN N IN VIOX 1P PROTECTOR Latching Relay · 40A / 63A / 80A L OUT N OUT To Branch MCBs / Load (L+N Only) B · THREE-PHASE BOTTOM-IN / TOP-OUT VOPD3-63VA / 100VA (Verify Terminal Marking) TOP OUT → 3-Phase Load (L1 / L2 / L3 / N) VIOX VOPD3-63VA / 100VA Per-Phase V+A · Phase Loss ON BOTTOM IN ← 3×220/380V Supply C · 3-PHASE IN → 1-PHASE OUT SELECTOR VOPD3-63VAYA / 100VAYA · VOAP2-100A Incoming L1 (Priority) · L2 · L3 · N AUTO PHASE SELECTOR Auto-Switches to Healthy Phase Critical 1P Load Out (63A / 100A)
Field Risk 01

Reversed 3-Phase Feed

Feeding top terminals on Bottom-IN VOPD3-63VA/100VA leaves internal sensing unpowered during disconnect. Always match housing IN/OUT markings.

Field Risk 02

L+L Split-Phase on WiFi

VOB9S-VAP and VOMPD-63LW require an L+N neutral reference. Never wire two 120V hot legs (L1+L2) into an L+N voltage protector.

Field Risk 03

Short Delay on HVAC

Default 30 s recovery delay is too brief for refrigerator or chiller compressors. Program A1/A4/A8 to 180–300 s to prevent locked-rotor trips.

Field Risk 04

Overloading Control Relays

VOMPD-8S and VOMPD-AD220 are 6A control monitoring relays. Pair them with a VIOX AC contactor coil rather than switching 63A loads directly.

05 · Manufacturing & Quality Proof

VIOX Factory Calibration, Latching Endurance & OEM Supply

Built on automated calibration benches with flame-retardant housings and customizable distributor firmware defaults.

VIOX QC 01

100% Threshold Calibration

Every unit undergoes automated over-voltage, under-voltage, and over-current trip verification before carton sealing (≤1% full-scale accuracy on VOPD3).

VIOX QC 02

Magnetic Latching Relays

High-capacity latching relays hold closed without continuous coil heat, keeping self-consumption ≤2 W and rated endurance ≥100,000 cycles.

VIOX QC 03

OEM Firmware & Branding

Custom factory default thresholds (110V/220V/230V), laser-etched private labels, and multilingual manuals available for distributor volume orders.

VIOX QC 04

CE / LVD / EMC / RoHS

Flame-retardant PA66 housings, IP20 finger-safe tunnel terminals, and compliance with EU Low Voltage (2014/35/EU) and EMC (2014/30/EU) directives.

06 · Factory Quotation Builder

Build Your Voltage Protector RFQ Brief

Configure supply type, current rating, smart/leakage features, and OEM requirements to prefill our engineering quote form in one click.

1. Supply & Architecture

2. Load Current Tier

3. Smart, Leakage & Metering Options

4. Supply / OEM Scope

Voltage Protector Engineering FAQ

Direct answers on Top-IN vs. Bottom-IN wiring, SYN/ASY 3-phase modes, auto phase selection, L+N WiFi limits, and HVAC delay tuning.

Okablowanie Are all VIOX DIN-rail voltage protectors wired Top-IN and Bottom-OUT?

No. Single-phase DIN-rail models (VOPD1-63VAE, VOPD1-60-EC, VOMPD-63LW, VOB9S-VAP) use Top-IN, Bottom-OUT wiring ("over-entering down-out").

Three-phase VOPD3-63VA and VOPD3-100VA wire Bottom-IN (supply) and Top-OUT (load). Always check the IN/OUT terminal markings printed on the housing before energizing.

3-Phase Modes When should I choose SYN (Synchronous) vs. ASY (Asynchronous) mode on VOPD3-63VAS / 100VAS?

Use SYN (Synchronous) mode for 3-phase motors, pumps, and compressors where losing one phase causes winding burnout — all three relays open together on any single-phase fault.

Use ASY (Asynchronous) mode for commercial buildings or multi-apartment boards feeding independent single-phase loads, so a fault on L1 disconnects only L1 while L2 and L3 keep running.

Phase Selector How does an Automatic Phase Selector (VOPD3-63VAYA / VOAP2-100A) protect critical single-phase loads?

It connects three incoming phases (L1, L2, L3 + N) and feeds a single-phase output load up to 63 A or 100 A via built-in magnetic latching relays.

If the active priority phase suffers over-voltage, under-voltage, or outage, the selector automatically transfers the load to a healthy backup phase and optionally returns to the priority phase once stable.

WiFi & Split-Phase Can I wire VOB9S-VAP or VOMPD-63LW on a 240V L+L split-phase circuit without neutral?

No. VIOX single-phase WiFi protectors (VOB9S-VAP, VOMPD-63LW, VOVA-63T) require an L+N single-phase supply (AC 85–300 V / 140–300 V).

Connecting two hot legs (L1+L2 without neutral) violates the internal sensing and relay architecture and will damage the unit. For two-wire dual-pole disconnection on L+N systems, specify VOPD1-63DK.

Zakres ochrony What is the difference between a load-carrying Voltage Protector and a Voltage Monitoring Relay?

Load-carrying voltage protectors (VOPD1, VOPD3, VOMPD-63LW, VOSVA-16) switch 16 A to 125 A loads directly through an internal magnetic latching relay.

Voltage monitoring relays (VOMPD-8S, VOMPD-AD220) carry 6 A–10 A dry control contacts (1CO / 1NO+1NC) that drive an external AC contactor coil or shunt trip for heavy industrial switchgear.

HVAC & Compressors What power-on and recovery delay should I set for refrigerators, chillers, and HVAC compressors?

Factory default recovery delay is typically 30 seconds (adjustable 1–500 s). For refrigeration compressors and split AC units, set power-on delay (A1/P1) and fault recovery delay (A4/A8) to 180–300 seconds so refrigerant head pressure equalizes before restart.

Sourcing DIN-Rail Voltage Protectors or Auto Phase Selectors?
Get Direct Factory Pricing.

Share your target current tier (16A–125A), voltage standard (110V/230V/380V), WiFi/leakage requirements, or private-label volume. VIOX engineers respond within 24 hours.

Request Voltage Protector Quote