VIOX RT18-32 DINレールマウントヒューズホルダー
- 10x38mmカートリッジヒューズ対応
- 1極、2極、3極、4極の構成で利用可能
- 定格690V、32A、遮断容量100kA
- 35mmDINレールへの容易な取り付け
- 耐高温PBT構造(120℃まで)
- ワイヤー範囲AWG 20-8 / 0.52-8.4 mm² (AWG 20-8 / 0.52-8.4 mm²)
- IEC60269-2およびGB/T13539.2規格準拠
- UL 94V-0、V-2難燃グレード
- 工具不要のヒューズ取り付けと交換
- CE承認およびRoHS対応
- 産業用制御盤および配電システムに最適
- スペース効率に優れたコンパクト設計
あなたの条件を送りなさい、私達は12時間以内にあなたのために引用する
- TEL:+8618066396588
- Whatsapp:+8618066396588
- Email:sales@viox.com
RT18 Series Cylindrical Contact Cap Fuses
The RT18 series cylindrical contact cap fuses represent the pinnacle of electrical protection technology, designed to safeguard your electrical systems against overcurrent conditions with exceptional reliability and precision. These high-performance fuses comply with international standards and offer versatile protection for various applications in industrial and commercial environments.
製品概要
RT18 fuses are meticulously engineered cylindrical contact cap fuses that provide superior protection for electrical circuits, equipment, and components. Their robust design ensures consistent performance under demanding conditions, making them an essential safety component in modern electrical installations.
Whether you’re protecting conductors, motors, or semiconductor devices, the RT18 series offers specialized protection classes to meet your specific requirements. With compliance to IEC60269-2 and GB/T13539.2 standards, these fuses deliver peace of mind through reliable overcurrent protection.
主な特徴と利点
- 国際的なコンプライアンス Manufactured in accordance with IEC60269-2 and GB/T13539.2 standards, ensuring global acceptance and reliability
- 高電圧定格: Available for systems operating at AC400V, AC500V, and 690V
- Excellent Breaking Capacity: AC 100kA rated breaking capacity for reliable protection during fault conditions
- Versatile Protection Classes:
- gL/gG class for conductor protection
- aM class for motor protection
- aR class for semiconductor protection
- Multiple Size Options: Available in various dimensions to fit different installation requirements
- 高品質な構造: Precision-engineered for consistent performance and long service life
- ISO9001, UL, TUV, and CE Certified: Ensuring quality and safety standards are consistently met
技術仕様
Standards Compliance
All RT18 fuses are manufactured according to IEC60269-2 and GB/T13539.2 standards, guaranteeing consistent quality and performance across the entire product line.
Electrical Ratings
パラメータ | 仕様 |
---|---|
定格電圧 | AC400V, AC500V, 690V |
Rated Breaking Capacity | AC 100kA |
Rated Currents (Fuse Holders) | 32A, 63A, 125A |
Utilization Category | AC-20B, DC-20B |
Protection Classes
Class | 申し込み |
---|---|
gL/gG | General-purpose protection for conductors and cables |
aM | Motor protection against short circuits |
aR | Semiconductor protection for sensitive electronic components |
Physical Dimensions
The RT18 series is available in multiple sizes to accommodate different installation requirements:
Size (Diameter × Length) | 寸法(mm) | 直径 (mm) |
---|---|---|
8.5×31.5 | 31.5±0.5 | Ø8.5±0.1 |
10×38 | 38±0.6 | Ø10.3±0.1 |
14×51 | 51±0.8 | Ø14.3±0.1 |
22×58 | 58±1 | Ø22.2±0.1 |
Compatible Fuse Holders
The RT18 series includes compatible fuse holders for convenient installation and maintenance:
RT18 Fuse Holder Series
- RT18-32 and RT18-32X: Fuse holders for smaller amperage applications (with LED indicator option on X model)
- RT18-63 and RT18-63X: Medium-capacity fuse holders (with LED indicator option on X model)
- RT18-125 and RT18-125X: High-capacity fuse holders for demanding applications (with LED indicator option on X model)
アプリケーション
RT18 cylindrical contact cap fuses are ideal for a wide range of applications across various industries:
産業用途
- 製造装置の保護
- モーター・コントロール・センター
- 産業用制御盤
- Machinery and automation systems
- Production line equipment
- 配電システム
商業用途
- Building electrical systems
- HVAC equipment protection
- 業務用照明システム
- Office equipment protection
- Telecommunication systems
スペシャライズド・プロテクション
- Semiconductor device protection (using aR class)
- Motor startup protection (using aM class)
- General circuit protection (using gL/gG class)
- 配電盤
- Control circuit protection
Selection Guide
Choosing the right RT18 fuse for your application involves considering several key factors:
1. Voltage Rating
Select a fuse with a voltage rating equal to or greater than your system’s nominal voltage. The RT18 series offers options for AC400V, AC500V, and 690V systems.
2. Current Rating
Determine the maximum normal operating current of your circuit and select a fuse with an appropriate rating. Remember that fuses should be sized according to circuit conductor capacity and load requirements.
3. Breaking Capacity
Ensure the fuse’s breaking capacity (100kA for RT18 series) exceeds the maximum prospective short-circuit current at the point of installation.
4. Protection Class
Choose the appropriate protection class based on your application:
- gL/gG: For general conductor and cable protection
- aM: For motor circuit protection
- aR: For semiconductor protection
5. Physical Size
Select the appropriate physical dimensions based on your installation constraints and fuse holder requirements.
設置ガイドライン
For optimal performance and safety, follow these installation guidelines when using RT18 fuses:
- Always ensure the power is disconnected before installing or replacing fuses
- Verify that the fuse rating and size match your application requirements
- Install fuses in appropriate holders designed for the specific size and rating
- Ensure proper connection and tightening of all electrical terminals
- Verify that the fuse orientation is correct (if applicable)
- Check for any signs of damage before installation
- Follow local electrical codes and standards during installation
Maintenance Recommendations
To ensure continued protection and reliability, consider these maintenance practices:
- Regularly inspect fuses for signs of overheating, discoloration, or damage
- Check fuse holders for secure connections and signs of wear
- Replace blown fuses with identical ratings and types
- Never attempt to repair or modify a fuse
- Document fuse replacements to identify recurring issues
- Conduct periodic thermal scanning to identify potential issues before failure
品質保証
VIOX RT18 fuses undergo rigorous testing and quality control procedures to ensure consistent performance and reliability. Our commitment to quality is reflected in our ISO9001 certification and compliance with international standards such as UL, TUV, and CE.
Each fuse is tested for electrical performance, mechanical integrity, and dimensional accuracy before leaving our facility, ensuring that you receive a product that meets the highest standards of quality and safety.
Why Choose VIOX RT18 Fuses?
- 信頼性: Engineered for consistent performance under demanding conditions
- 安全だ: Provides superior protection against overcurrent and short-circuit conditions
- 汎用性がある: Available in multiple sizes and protection classes to suit various applications
- コンプライアンス: Meets international standards for quality and safety
- 耐久性がある: Constructed with high-quality materials for extended service life
- 互換性: Designed to work seamlessly with RT18 series fuse holders
ご注文について
When ordering RT18 fuses, please specify the following information to ensure you receive the correct product:
- Model number (RT18)
- Size (8.5×31.5, 10×38, 14×51, or 22×58)
- Current rating
- Voltage rating (AC400V, AC500V, or 690V)
- Protection class (gL/gG, aM, or aR)
- Quantity required
- Any special requirements or certifications needed
結論
VIOX RT18 cylindrical contact cap fuses provide exceptional protection for your electrical systems, combining reliability, performance, and safety in a compact and versatile package. With multiple size options, protection classes, and voltage ratings, there’s an RT18 fuse perfectly suited for your specific application.
Trust in the quality and performance of VIOX RT18 fuses to safeguard your valuable equipment and ensure the uninterrupted operation of your electrical systems. Contact our technical support team today for assistance with selecting the right RT18 fuses for your specific requirements.