VIOX ELECTRIC
Langue

VIOX VSP-T25/B+C Heavy-Duty AC Type 1+2 Lightning & Surge Arrester (Iimp 25kA)

The VIOX VSP-T25/B+C is a heavy-duty Type 1 + Type 2 (B+C) lightning current and surge arrester engineered for LPS Class I & II buildings, substations, and industrial main switchboards. Rated for Iimp 25 kA (10/350 μs) per pole and Imax 50 kA (8/20 μs) across Uc 275 V, 350 V, and 440 V AC with low Up 1.2–2.0 kV protection and zero follow-current leakage.

Série VIOX
VSP-T25/B+C
Tension nominale
AC 275V / 350V / 440V
Surge Rating
Iimp 25 kA (10/350μs) · Imax 50 kA
Standard
IEC 61643-11 · T1+T2 · CE / CB

Vue d'ensemble

The VIOX VSP-T25/B+C is a heavy-duty Type 1 + Type 2 (B+C) lightning current and surge arrester engineered for LPS Class I & II buildings, substations, and industrial main switchboards. Rated for Iimp 25 kA (10/350 μs) per pole and Imax 50 kA (8/20 μs) across Uc 275 V, 350 V, and 440 V AC with low Up 1.2–2.0 kV protection and zero follow-current leakage.

Caractéristiques

  • Full 25 kA (10/350 μs) lightning current per pole (100 kA total in 4P / 3+NPE) for LPS Class I/II main service entrances.
  • Dual-rated Type 1 + Type 2 (Iimp 25 kA / In 25 kA / Imax 50 kA) eliminates decoupling inductors between T1 and T2 stages.
  • Available in Uc 275 V, 350 V, and 440 V AC with Up 1.2 / 1.6 / 2.0 kV and 50,000 A short-circuit withstand (Isccr).
  • Heavy-duty 36 mm/pole black flame-retardant PBT/PA enclosure with pluggable cartridges and 11/12/14 remote alarm contacts.

Spécifications

VSP-T25/B+C Electrical & Mechanical Specifications

ParamètreSpécification
SPD ClassificationType 1 + Type 2 (T1+T2) · IEC 61643-11 / EN 61643-11
Max Continuous Operating Voltage (Uc)275 V / 350 V / 440 V AC (L-N) · 255 V AC (N-PE)
Lightning Impulse Current (Iimp, 10/350 μs)25 kA per pole (L-N & N-PE)
Nominal / Max Discharge Current (8/20 μs)In 25 kA · Imax 50 kA
Niveau de protection de tension (Up)1.2 / 1.6 / 2.0 kV (L-N) · 1.5 kV (N-PE)
Response Time & Leakage25 ns (L-N) / 100 ns (N-PE) · Ipe: NONE · Isccr: 50,000 A
Recommended Backup SCBVIOX VSP-SSD50X
Terminals & Housing6–35 mm² (2.5 N·m) · Black PBT/PA UL94 V-0 · IP20 · 35 mm DIN rail

VSP-T25/B+C Available Poles & Dimensions

Pôles1P1+NPE / 2P3P4P / 3+NPE
Dimensions (W × H × D)36 × 90 × 92 mm72 × 90 × 92 mm108 × 90 × 92 mm144 × 90 × 92 mm

Dimensions et Installation

VIOX VSP-T25/B+C Heavy-Duty AC Type 1+2 Lightning & Surge Arrester (Iimp 25kA) Dimensional Drawing (mm)
VSP-T25/B+C Outline & DIN-Rail Mounting Dimensions (unit: mm)
  • Use ≥16 mm² copper phase conductors and ≥25 mm² main earthing conductor to handle 25 kA (10/350 μs) lightning current.
  • Coordinate upstream with VIOX VSP-SSD50X dedicated Type 1 backup disconnector.
  • Explore the complete VIOX Surge Protection Devices (SPD) catalog for matched AC, Solar PV DC, and SCB backup protection.

FAQ

What is the difference between VSP-T15/B+C (12.5kA) and VSP-T25/B+C (25kA)?

VSP-T15/B+C (12.5 kA, 18 mm/pole) fits LPS Class III/IV commercial buildings and space-limited panels; VSP-T25/B+C (25 kA, 36 mm/pole) meets strict LPS Class I/II utility, hospital, and industrial main switchboard specifications.

Besoin d'un devis produit ?
Construisons-le ensemble.

Envoyez-nous le modèle du produit, les caractéristiques techniques, la quantité et les exigences OEM. Notre équipe examinera votre demande et vous répondra dans un délai d'un jour ouvré.

Demander un Devis