VIOX ELECTRIC
Язык

VIOX VSP-T25/B+C Heavy-Duty AC Type 1+2 Lightning & Surge Arrester (Iimp 25kA)

The VIOX VSP-T25/B+C is a heavy-duty Type 1 + Type 2 (B+C) lightning current and surge arrester engineered for LPS Class I & II buildings, substations, and industrial main switchboards. Rated for Iimp 25 kA (10/350 μs) per pole and Imax 50 kA (8/20 μs) across Uc 275 V, 350 V, and 440 V AC with low Up 1.2–2.0 kV protection and zero follow-current leakage.

Серия VIOX
VSP-T25/B+C
Номинальное напряжение
AC 275V / 350V / 440V
Surge Rating
Iimp 25 kA (10/350μs) · Imax 50 kA
Стандарт
IEC 61643-11 · T1+T2 · CE / CB

Обзор

The VIOX VSP-T25/B+C is a heavy-duty Type 1 + Type 2 (B+C) lightning current and surge arrester engineered for LPS Class I & II buildings, substations, and industrial main switchboards. Rated for Iimp 25 kA (10/350 μs) per pole and Imax 50 kA (8/20 μs) across Uc 275 V, 350 V, and 440 V AC with low Up 1.2–2.0 kV protection and zero follow-current leakage.

Характеристики

  • Full 25 kA (10/350 μs) lightning current per pole (100 kA total in 4P / 3+NPE) for LPS Class I/II main service entrances.
  • Dual-rated Type 1 + Type 2 (Iimp 25 kA / In 25 kA / Imax 50 kA) eliminates decoupling inductors between T1 and T2 stages.
  • Available in Uc 275 V, 350 V, and 440 V AC with Up 1.2 / 1.6 / 2.0 kV and 50,000 A short-circuit withstand (Isccr).
  • Heavy-duty 36 mm/pole black flame-retardant PBT/PA enclosure with pluggable cartridges and 11/12/14 remote alarm contacts.

Технические характеристики

VSP-T25/B+C Electrical & Mechanical Specifications

ПараметрСпецификация
SPD ClassificationType 1 + Type 2 (T1+T2) · IEC 61643-11 / EN 61643-11
Max Continuous Operating Voltage (Uc)275 V / 350 V / 440 V AC (L-N) · 255 V AC (N-PE)
Lightning Impulse Current (Iimp, 10/350 μs)25 kA per pole (L-N & N-PE)
Nominal / Max Discharge Current (8/20 μs)In 25 kA · Imax 50 kA
Уровень защиты по напряжению (Up)1.2 / 1.6 / 2.0 kV (L-N) · 1.5 kV (N-PE)
Response Time & Leakage25 ns (L-N) / 100 ns (N-PE) · Ipe: NONE · Isccr: 50,000 A
Recommended Backup SCBVIOX VSP-SSD50X
Terminals & Housing6–35 mm² (2.5 N·m) · Black PBT/PA UL94 V-0 · IP20 · 35 mm DIN rail

VSP-T25/B+C Available Poles & Dimensions

Полюса1P1+NPE / 2P3P4P / 3+NPE
Dimensions (W × H × D)36 × 90 × 92 mm72 × 90 × 92 mm108 × 90 × 92 mm144 × 90 × 92 mm

Размеры и установка

VIOX VSP-T25/B+C Heavy-Duty AC Type 1+2 Lightning & Surge Arrester (Iimp 25kA) Dimensional Drawing (mm)
VSP-T25/B+C Outline & DIN-Rail Mounting Dimensions (unit: mm)
  • Use ≥16 mm² copper phase conductors and ≥25 mm² main earthing conductor to handle 25 kA (10/350 μs) lightning current.
  • Coordinate upstream with VIOX VSP-SSD50X dedicated Type 1 backup disconnector.
  • Explore the complete VIOX Surge Protection Devices (SPD) catalog for matched AC, Solar PV DC, and SCB backup protection.

ЧАСТО ЗАДАВАЕМЫЕ ВОПРОСЫ

What is the difference between VSP-T15/B+C (12.5kA) and VSP-T25/B+C (25kA)?

VSP-T15/B+C (12.5 kA, 18 mm/pole) fits LPS Class III/IV commercial buildings and space-limited panels; VSP-T25/B+C (25 kA, 36 mm/pole) meets strict LPS Class I/II utility, hospital, and industrial main switchboard specifications.

Нужен расчет стоимости продукции?
Давайте создавать вместе.

Отправьте нам модель изделия, технические характеристики, количество и требования OEM. Наша команда рассмотрит вашу заявку и ответит в течение одного рабочего дня.

Запрос Цитировать