VIOX ELECTRIC
زبان
Direct Factory · IEC 60947-3 Rotary Cam Switch & Load Disconnector Manufacturer

Rotary Cam Switches & Load Disconnect Switches (LW26 / LW30) 10A–160A Universal Cam Switches (ON-OFF, Changeover 1-0-2, Motor Reversing, Selector) & 20A–125A Main Isolators

VIOX Electric manufactures heavy-duty LW26 rotary cam switches (10A–160A, up to 12 contact decks) and LW30 load disconnect switches (20A–125A, IP65 padlockable) engineered for switchgear panels, three-phase motor reversing, manual generator changeover, and industrial machine control.

10A – 160ALW26 Cam · LW30 Disconnect
AC-21A / AC-23A / AC-3IEC 60947-3 · 690V AC
30 درجه / 45 درجه / 60 درجه / 90 درجهCustom Programs · IP65 Front
VIOX LW26 10A to 160A industrial rotary cam switch and LW30 load disconnect switch
01 · Core Definition & Series Scope

What Is a Rotary Cam Switch? (LW26 vs. LW30 Overview)

A کلید کم گردان (همچنین به عنوان کلید کم یا industrial rotary switch) is a multi-pole mechanical switching device whose central shaft rotates profiled insulating cams to open and close stacked double-break silver-alloy contacts in an exact programmed sequence. Unlike single-function toggle switches, one compact panel-mounted cam switch executes complex ON-OFF, 1-0-2 changeover, motor reversing, or voltmeter selection logic.

Within VIOX’s low-voltage switching portfolio, the LW26 rotary cam switch handles custom multi-deck control and power transfer from 10A to 160A, while the LW30 load disconnect switch provides dedicated 20A–125A main-panel AC-23A load breaking with padlockable emergency handles and door-interlock shafts. For solar PV DC isolation, pair with our Solar DC Isolator Switch Hub.

Why Engineers Specify Cam Switches
  • Positive Double-Break Action: Two contact gaps per pole quench AC-23A / AC-3 inductive arcs rapidly.
  • Modular Deck Stacking: Combine 1 to 12 independent wafers (up to 24 contacts) on one 48–88 mm bezel.
  • Padlockable Lockout-Tagout: Red-yellow emergency OFF handles accept up to 3 safety padlocks.
  • Visual Panel Status: جفت کنید با نشانگرهای موقعیت سوئیچ VIOX on mimic switchboards.
02 · Four Standard Industrial Switching Functions

4 Core Switching Functions: ON-OFF, Changeover, Motor Reversing & Selector

Every industrial rotary cam switch is defined by its switching program. Select from four standard factory-stocked topologies or submit a custom contact chart.

Program 01 · ON-OFF (0–1 · 90°)

ON-OFF Cam Switch & Main Load Isolator

Simultaneously breaks 1P, 2P, 3P, 4P, or 6P power circuits across a positive 90° throw. Specify LW30 (20A–125A) or LW26 (10A–160A) with IP65 front seals and padlockable red-yellow handles for IEC 60204-1 machine main disconnects.

Program 02 · Changeover (1–0–2 · 60°)

Manual Changeover Cam Switch (Mains / Generator)

Break-before-make center-OFF transfer switching between two power sources or two load banks without cross-feeding. Need automated unmanned transfer? Compare against our Automatic Transfer Switch (ATS) Hub.

Program 03 · Motor Reversing (1–0–2 · 60°)

Three-Phase Motor Reversing Cam Switch

Swaps phases L1 and L3 internally through factory copper jumpers across 3 contact decks to reverse three-phase hoists, lathes, and conveyors cleanly through a mandatory center-OFF pause. Also available in 2-speed Dahlander and star-delta starter programs.

Program 04 · Instrumentation (45° / 90°)

Rotary Cam Selector Switch (Voltmeter & Ammeter)

Monitors all three line-to-line (L1-L2, L2-L3, L3-L1) and phase-to-neutral voltages using a single panel meter, or switches three CT secondaries with make-before-break shorting bridges so current transformers never open-circuit under load.

03 · Flagship Series Lineup & Technical Matrix

Compare VIOX LW26 Cam Switches & LW30 Load Disconnect Switches

Compare our two core industrial rotary platforms side-by-side and inspect full product datasheets below.

Table 1: VIOX LW26 Rotary Cam Switch vs. LW30 Load Disconnect Switch Comparison Matrix
مشخصات سوئیچ بادامکی چرخشی LW26 سوئیچ قطع بار LW30
Rated Thermal Current (Ith)10A, 20A, 25A, 32A, 63A, 125A, 160A20A, 25A, 32A, 40A, 63A, 80A, 100A, 125A
ولتاژ عایق نامی (UI)690V AC (50/60 Hz)690V AC (IEC 60947-3)
دسته بندی های استفادهAC-21A, AC-23A, AC-3 (Motor), AC-15 (Control)AC-21A, AC-22A, AC-23A (Main Load Break)
Poles & Contact Decks1 to 12 decks (2–24 contacts, custom programs)3P, 4P, 6P + optional auxiliary NO/NC blocks
Front Escutcheon / Cutout48×48 mm (10–25A) · 64×64 mm (32–63A) · 88×88 mm (125–160A)48×48 mm / 64×64 mm · 4-hole, single-hole Ø22.5 mm, DIN rail & door shaft
درجه حفاظت در برابر نفوذ (IP)IP20 terminals · IP40 / IP65 front bezel sealIP20 finger-safe terminals · IP65 padlockable handle / IP65 box
برنامه های کاربردی معمولیMotor reversing, 1-0-2 changeover, voltmeter/ammeter selector, weldersSwitchboard main isolator, machine tool emergency OFF, motor local disconnect
04 · Interactive Program Configurator & Switching Table

How to Specify a Cam Switch (Switching Program, Current, Poles & Mounting)

Select your switching function and load current below to match the exact LW26 or LW30 configuration, or review our cam switch switching-program guide و step-by-step cam switch wiring diagrams.

1. Required Switching Program
2. Rated Operational Current (Ith / AC-23A)
Table 2: Standard Industrial Cam Switch Switching Programs Quick-Reference
Switching Program Handle Positions Indexing Angle Contact Decks (3-Phase) سری VIOX پیشنهادی
ON-OFF Main Isolator0 – 1 (2 Positions)90° (or 60°)2 Decks (3P / 4P)LW30 (20A–125A) · LW26 (10A–160A)
Changeover Switch1 – 0 – 2 (Center OFF)60° (or 45°)3–4 Decks (3P / 4P)LW26 (Manual) · ATS (Auto)
Motor Reversing1 – 0 – 2 (Fwd-OFF-Rev)60°3 Decks (with L1/L3 jumpers)LW26 (10A–63A AC-3 Motor Duty)
Voltmeter / Ammeter Selector0–L1L2–L2L3–L3L1 (4–7 Pos.)45° or 30°2–3 Decks (CT shorting opt.)LW26-20 (10A / 20A Instrument)
05 · Panel Integration & Field Deployments

Industrial Applications & Panel Integration

1. Switchboard Main Load Isolation

LW30 3P/4P load disconnectors with door-interlock extended shafts prevent enclosure doors from opening while energized, meeting IEC 60204-1 safety rules on MCCs and distribution panels.

2. Three-Phase Motor Reversing & Multi-Speed Control

LW26 reversing and Dahlander cam switches provide direct-on-line forward/reverse and 2-speed control for hoists, wood-working machinery, mixers, and industrial exhaust fans.

3. Voltmeter & Ammeter Panel Instrumentation

Compact 48×48 mm LW26-20 selector switches replace three separate meters with one multi-phase selector, complete with make-before-break CT shorting decks for safe ammeter switching.

4. Welding Machines & OEM Control Consoles

High-endurance multi-step LW26 cam stacks switch transformer tap windings on MIG/TIG welders, battery chargers, and CNC auxiliary circuits across 50,000+ mechanical cycles.

06 · Direct Factory Workshop & Technical Library

Inside VIOX Cam Switch Manufacturing, Silver-Alloy Contacts & OEM Customization

Real VIOX workshop views showing LW26 and LW30 rotary cam switches moving from staged mechanisms through bench assembly to completed inspection batches.

Silver-Alloy Double-BreakAgNi / AgCdO contacts on flame-retardant UL 94V-0 PA66 cam decks prevent contact welding under AC-3 surges.
Custom Switching ProgramsSend any X-table or schematic; we assemble custom 1–12 deck stacks, shafts & laser plates from $1,500 MOQ.
100% Continuity & Hi-PotEvery LW26 and LW30 switch passes automated deck-sequence verification and 2.5 kV dielectric testing.
07 · Frequently Asked Questions

Rotary Cam Switch Selection FAQ

LW26 vs. LW30 What is the difference between a VIOX LW26 rotary cam switch and an LW30 load disconnect switch?

LW26 is a multi-deck universal rotary cam switch (10A–160A) engineered for custom switching programs including 1-0-2 manual changeover, three-phase motor reversing, multi-speed Dahlander control, and voltmeter/ammeter selection. LW30 (20A–125A) is a dedicated IEC 60947-3 main load-break isolator (0–1, 90°) with padlockable red-yellow handles and door-interlock shafts for switchgear mains.

Motor Reversing How do I size a motor reversing cam switch for a three-phase induction motor?

Always size a motor reversing cam switch by its IEC 60947-3 AC-3 (motor load) kW/current rating rather than its higher AC-21A resistive thermal current (Ith). Use a 3-position 1-0-2 center-OFF program (60° indexing) so the operator pauses briefly at 0 before reversing two supply phases, preventing high plugging-current arcs across the silver-alloy contacts.

Manual vs. ATS When should I use a 1-0-2 changeover cam switch instead of an Automatic Transfer Switch (ATS)?

Choose an LW26 1-0-2 manual changeover cam switch when a trained operator switches between utility and backup generator power on demand at low cost and compact panel depth. Choose a VIOX Automatic Transfer Switch (/ats/) when unmanned power-failure detection and automatic millisecond-to-second transfer are required for hospitals, data centers, or critical pumps.

Custom Programs Can VIOX manufacture custom switching programs, contact decks, and laser-engraved escutcheon plates?

Yes. Send your contact closure table (X-table), switching angle (30°, 45°, 60°, or 90°), number of poles/decks (1 to 12 wafers), and desired front-plate markings. Our factory builds custom LW26 cam stacks with AgNi/AgCdO silver-alloy contacts and optional IP65 padlockable front seals from low OEM MOQs.

DC vs. AC Isolation Can an LW26 or LW30 AC rotary cam switch be used on 1000V–1500V solar PV DC strings?

No. Standard AC rotary cam switches and LW30 load disconnectors are rated for AC-21A/AC-23A up to 690V AC and low-voltage DC control circuits. For high-voltage 1000V–1500V solar PV arrays, always specify an IEC 60947-3 DC-PV2 rated VIOX Solar DC Isolator Switch (/dc-isolator-switch/).

Direct Factory LW26 & LW30 Rotary Switch Supply

Need Custom-Program LW26 Cam Switches or LW30 Load Disconnectors?

Share your switching diagram (X-table), rated current (10A–160A), panel cutout, and handle/IP65 requirements. VIOX engineers respond within 24 hours with drawings and OEM pricing.

LW26 (10A–160A) & LW30 (20A–125A)Custom 1–12 Deck ProgramsIP65 Padlockable & Door-Shaft Options