VIOX VSP1-C40PV/2(S) 1000V SPD unipolar enchufable
VIOX VSP1-C40PV/2(S) 1000V Pluggable Single-Pole SPD offers robust surge protection for high-voltage photovoltaic systems and DC applications. This Class I+II/Type 1+2 device safeguards (DC+) – PE and (DC-) – PE modes with 20kA nominal and 40kA maximum discharge current. Featuring high-energy MOV elements, it operates at 1000V DC with < 25ns response time. The pluggable design ensures easy installation on 35mm DIN rails. Compliant with IEC 61643-31:2018 and EN 50539-11:2013+A1:2014, it provides a voltage protection level of 3.6kV. With IP20 protection, thermal safeguards, and optional remote contacts, this versatile SPD combines reliability and performance for enhanced power system protection in demanding high-voltage DC and photovoltaic applications.
Envíenos sus requisitos, le haremos un presupuesto en 12 horas
- TEL:+8618066396588
- Whatsapp:+8618066396588
- Email:sales@viox.com
VIOX VSP1-C40PV/2(S) 1000V SPD unipolar enchufable
Visión general
The VIOX VSP1-C40PV/2(S) 1000V is a high-performance Pluggable Single-Pole Surge Protective Device (SPD) designed for use in sub-distribution boards. This versatile device offers robust protection for (DC+) – PE and (DC-) – PE modes, making it an ideal solution for high-voltage photovoltaic systems and other DC applications.
Características principales
- Class I, Class II, Type 1, Type 2 device
- Localización de uso: Subdistribution Boards
- Mode of Protection: (DC+) – PE, (DC-) – PE
- Capacidad de sobretensión: In = 20 kA (8/20 μs)
- IEC/EN/UL Category: Class I+II / Type 1+2
- Elementos de protección: MOV de alta energía
- Carcasa: Diseño enchufable
- Compliance: IEC 61643-31:2018, EN 50539-11:2013+A1:2014
Especificaciones técnicas
IEC Eléctrica | 1000 |
---|---|
Nominal AC Voltage | 1000 V |
Maximum Continuous Operating Voltage (DC) | 1000 V |
Corriente nominal de descarga (8/20 μs) | 20 kA |
Corriente máxima de descarga (8/20 μs) | 40 kA |
Impulse Discharge Current (10/350 μs) | 6.25 kA |
Nivel de protección de tensión | 3.6 kV |
Tiempo de respuesta | < 25 ns |
Fusible de reserva (máx.) | 125 A gL / gG |
Corriente de cortocircuito (CA) | 25 kA / 50 kA |
Especificaciones mecánicas y medioambientales
- Temperatura de funcionamiento: -40°C a +70°C [-40°F a +158°F]
- Humedad de funcionamiento admisible: 5%...95%
- Presión atmosférica y altitud: 80k Pa ... 106k Pa / -500 m....2000 m
- Par de apriete del tornillo del terminal: 39.9 lbf.in [4.5 Nm]
- Sección del conductor (máx.) 2 AWG (sólido, trenzado) / 4 AWG (flexible)
- 35 mm² (sólido, trenzado) / 25 mm²(flexible)
- Montaje: Carril DIN de 35 mm, EN 60715
- Grado de protección: IP 20 (integrado)
- Material de la carcasa: Termoplástico: Grado de extinción UL 94 V-0
- Protección térmica: Sí
- Estado de funcionamiento / Indicación de fallo: Verde correcto / Rojo defectuoso
Características adicionales
- Contactos remotos (RC): Opcional
- Capacidad de conmutación RC: AC: 250V / 0,5 A; DC: 250V / 0,1 A;125V / 0,2 A;75V / 0,5 A
- Sección del conductor RC (máx.) 16 AWG (sólido) / 1,5 mm²(sólido)