VIOX CTB101015 Ceramic Terminal Block offers a 10-in-10-out, 15A design for maximum high-density multi-circuit needs. With 750°C heat resistance, it’s ideal for automation and telecommunications. Trust VIOX for reliable, space-efficient solutions in extreme industrial environments.

Envíenos sus requisitos, le haremos un presupuesto en 12 horas

The CTB101015 Ceramic Terminal Block represents the pinnacle of high-density multi-circuit connection technology, offering unprecedented flexibility for complex electrical systems requiring extensive parallel connections. This professional-grade 10-in-10-out terminal block combines a 15A current rating with superior thermal stability and exceptional electrical insulation properties, making it the definitive choice for engineers and electricians working on highly sophisticated projects requiring numerous medium-current connections with maximum reliability and absolute space efficiency.

Maximum-Capacity Multi-Circuit Design for Advanced Electrical Systems

The CTB101015 features an industry-leading 10-in-10-out configuration specifically engineered to maximize connection capacity while maintaining a practical form factor. Precision-manufactured from high-frequency ceramic material, this terminal block delivers superior insulation properties that significantly outperform conventional plastic alternatives in medium-current, high-temperature environments. The ceramic housing ensures complete resistance to aging, cracking, and deformation even under extreme temperature conditions up to 750°C, guaranteeing long-term stability and safety for your most complex electrical installations.

Each terminal block incorporates twenty precision-engineered connection points with copper core conductors for optimal electrical performance and M3-compatible screw terminals manufactured from durable iron-plated zinc material. This construction provides secure and reliable wire clamping that withstands vibration and thermal cycling without loosening over time, ensuring consistent electrical contact across all ten circuits in demanding applications where connection integrity is critical.

Principales características y ventajas técnicas

  • Maximum Connection Density: Ten-in, ten-out design enables highly complex multi-circuit configurations for the most sophisticated electrical systems
  • Extended Linear Configuration: 88mm length provides exceptional organization of multiple connection points while maintaining secure wire termination
  • Optimized Mounting System: Built-in 49.5mm spaced mounting holes for secure and standardized installation in control panels
  • Compatibilidad con tornillos M3: Diseñado para funcionar con tornillos M3 estándar para conexiones seguras en aplicaciones con poco espacio
  • Enhanced Wire Capacity: Accommodates wire gauges from 0.5mm² to 2.5mm², with additional capacity up to 3.5mm² for flexibility in medium-current installations
  • Resistencia superior a la temperatura: Soporta el funcionamiento continuo a altas temperaturas de hasta 750°C, ideal para aplicaciones en las que los terminales de plástico fallarían
  • Excelente aislamiento eléctrico: El material cerámico proporciona una excepcional resistencia dieléctrica y evita las fugas de corriente entre circuitos adyacentes
  • Ignífugo: El material naturalmente ignífugo elimina el riesgo de ignición o propagación de la llama en instalaciones críticas
  • Resistencia química: Impermeable a aceites, disolventes y la mayoría de los ácidos, lo que garantiza su durabilidad en entornos industriales hostiles.
  • Balanced Design: Optimized 15mm height profile balances robustness with space efficiency

Especificaciones técnicas

ESPECIFICACIÓN MODELO LONGITUD ANCHO ALTURA RANGO DE CABLEADO
1 entrada 1 salida 10A CTB1110 19 mm 10 mm 15 mm 0,5-2,5 mm2
1 entrada 1 salida 30A CTB1130 18 mm 14 mm 18 mm 0,5-6 mm2
2 Entradas 2 Salidas 10A CTB2210 20,7 mm 18,9 mm 13,9 mm 0,5-2,5 mm2
2 Entradas 2 Salidas 15A CTB2215 28,4 mm 20,4 mm 16,3 mm 0,5-4 mm2
2 Entradas 2 Salidas 30A CTB2230 31 mm 27 mm 18,9 mm 1,5-6 mm2
2 Entradas 2 Salidas 60A CTB2260 38,7 mm 31 mm 22,7 mm 2,5-16 mm2
2 Entradas 2 Salidas 100A CTB22100 41,1 mm 30,2 mm 25,85 mm 6-25 mm2
3 Entradas 3 Salidas 10A CTB3310 31 mm 20 mm 14,3 mm 0,5-2,5 mm2
3 Entradas 3 Salidas 15A CTB3315 35,5 mm 20,3 mm 20,2 mm 0,5-4 mm2
3 Entradas 3 Salidas 30A CTB3330 46,2 mm 26,4 mm 19,2 mm 1,5-6 mm2
4 Entradas 4 Salidas 30A CTB4430 57 mm 25 mm 18,8 mm 1,5-6 mm2
5 Entradas 5 Salidas 15A CTB5515 50 mm 22 mm 13 mm 0,5-2,5 mm2
6 Entradas 6 Salidas 15A CTB6615 56,6 mm 21 mm 13 mm 0,5-2,5 mm2
8 Entradas 8 Salidas 15A CTB8815 68 mm 21 mm 13 mm 0,5-2,5 mm2
10 Entradas 10 Salidas 15A CTB101015 88 mm 18 mm 15 mm 0,5-3,5 mm2

CTB101015 Detailed Specifications:

  • Clasificación actual: 15 A por circuito
  • Configuración: Ten-in, Ten-out
  • Dimensiones: 88mm (L) × 18mm (W) × 15mm (H)
  • Alcance del cable: 0.5-3.5mm²
  • Diámetro del orificio de entrada del cable: 3 mm
  • Material de la carcasa: Cerámica de alta frecuencia
  • Material del conductor: Núcleo de cobre
  • Material del tornillo: Zinc chapado en hierro
  • Compatibilidad con tornillos: Rosca M3
  • Distancia del orificio de montaje: 49.5mm center-to-center
  • Tipos de cable compatibles: Adecuado para cables blandos y duros
  • Temperatura máxima de funcionamiento: 750°C
  • Rigidez dieléctrica: 3kV
  • Resistencia de aislamiento: >1000MΩ a 500VDC
  • Resistencia de contacto: <0,5mΩ
  • Par máximo: 0,6-0,8 N-m

Aplicaciones especializadas

The CTB101015 Ceramic Terminal Block is specifically designed for the most demanding high-density applications requiring extensive medium-current circuits with maximum connection flexibility:

  • Sistemas de control complejos: Industrial automation and process control systems requiring extensive parallel connections
  • Instrumentación multicanal: Advanced measurement and monitoring systems with numerous discrete channels
  • Redes de control distribuido: Large-scale industrial control systems with centralized connection of multiple distributed devices
  • Multi-Zone Building Management: Commercial building automation systems with comprehensive zone control
  • Communications Infrastructure: High-density telecommunications and networking equipment
  • Sistemas audiovisuales profesionales: High-end production and broadcast equipment requiring numerous isolated signal paths
  • Investigación y desarrollo: Laboratory testing apparatus requiring extensive isolated experimental circuits
  • Complex Sensing Networks: Industrial monitoring systems with extensive sensor arrays

Directrices de instalación profesional

For optimal performance and reliability in high-density multi-circuit applications, follow these specialized installation guidelines:

  1. Asegúrese de que la superficie de montaje esté limpia, sea plana y resistente al calor.
  2. Utilize the integrated 49.5mm mounting holes for secure attachment to mounting panels
  3. Implement a comprehensive circuit documentation system before installation to maintain proper identification
  4. Pelar los cables a la longitud adecuada (normalmente 5-7 mm)
  5. Afloje completamente los tornillos de los terminales antes de insertar los cables
  6. Inserte el cable completamente en la abertura del terminal
  7. Apriete los tornillos M3 con un par de 0,6-0,8 N-m, teniendo cuidado de no apretarlos demasiado.
  8. Compruebe que la conexión es segura tirando suavemente de cada cable.
  9. Apply a systematic labeling scheme to identify each circuit for future maintenance
  10. Mantenga un espacio libre adecuado alrededor del bloque de terminales para una correcta disipación del calor.

The CTB101015 Advantage: The Ultimate in Connection Flexibility

For the most sophisticated electrical systems requiring extensive connection points, the CTB101015 Ceramic Terminal Block offers the definitive solution in high-density terminal technology. Its unprecedented ten-in, ten-out configuration provides maximum connection capacity while maintaining professional-grade reliability – making it the ultimate choice for complex electrical systems where extensive circuit connections must be accommodated without compromising on connection integrity, thermal stability, or long-term performance.