Residual Current Circuit Breakers (RCCB)
Compare VIOX RCCB series by rated current, pole configuration, rated residual operating current and waveform type for low-voltage earth-leakage protection.
Λειτουργία προστασίαςResidual-current detection
Επιλογές πόλων2P and 4P by series
ΕυαισθησίαConfirm IΔn by model
Τύπος RCCBMatch load waveforms
What is a residual current circuit breaker?
An RCCB monitors the balance between current flowing through the outgoing and returning conductors. When the residual current exceeds the device operating characteristics, it disconnects the circuit to support earth-leakage protection.
An RCCB is not selected by rated current alone. Pole configuration, rated residual operating current, RCCB type, circuit voltage and coordination with overload and short-circuit protection must also match the installation.
RCCB Series Overview
Σύγκριση των δημοσιευμένων μοντέλων VIOX χρησιμοποιώντας δεδομένα που είναι ήδη διαθέσιμα στα στοιχεία του προϊόντος.
VIOX VKL11F
Διακόπτης διαρροής έντασης- Πολωνοί
- 2P
VIOX VKL11F
Διακόπτης διαρροής έντασης- Πολωνοί
- 4P
VIOX VRC1-125-B
Διακόπτης διαρροής έντασης- Πολωνοί
- 2P
- Ονομαστικό ρεύμα
- 100A
VIOX VRC3-63
Διακόπτης διαρροής έντασης- Πολωνοί
- 2P
- Ονομαστικό ρεύμα
- 25A
VIOX VKL11
Διακόπτης διαρροής έντασης- Πολωνοί
- 2P
VIOX VKL11
Διακόπτης διαρροής έντασης- Πολωνοί
- 4P
VIOX VKL11
Διακόπτης διαρροής έντασης- Πολωνοί
- 2P
- Τύπος RCCB
- Τύπος Α
VIOX VKL11
Διακόπτης διαρροής έντασης- Πολωνοί
- 4P
- Τύπος RCCB
- Τύπος Α
How to choose an RCCB
Use these checkpoints for preliminary comparison, then verify the exact model documentation and installation requirements.
Rated residual current
Match IΔn to the protection objective and applicable installation requirements.
RCCB waveform type
Choose Type AC, A, F, B or another available type according to the connected loads and standards.
Διαμόρφωση πόλου
Confirm the required 2P or 4P arrangement, circuit voltage and neutral configuration.
Συντονισμός υπερέντασης
Coordinate the RCCB with the required MCB, fuse or other overcurrent protective device.
RCCB waveform types
Type availability varies by VIOX series. Confirm the product datasheet and applicable installation standard before selection.
Compare published RCCB series
Τα κενά κελιά σημαίνουν ότι η τιμή δεν είναι διαθέσιμη στην τρέχουσα σύνοψη προϊόντος. Ανοίξτε τη σελίδα του μοντέλου ή ζητήστε το δελτίο τεχνικών δεδομένων του πριν από τον καθορισμό των προδιαγραφών.
| Σειρά | Πολωνοί | Ονομαστικό ρεύμα | Τύπος RCCB | Ευαισθησία |
|---|---|---|---|---|
| VIOX VKL11F | 2P | — | — | — |
| VIOX VKL11F | 4P | — | — | — |
| VIOX VRC1-125-B | 2P | 100A | — | — |
| VIOX VRC3-63 | 2P | 25A | — | — |
| VIOX VKL11 | 2P | — | — | — |
| VIOX VKL11 | 4P | — | — | — |
| VIOX VKL11 | 2P | — | Τύπος Α | — |
| VIOX VKL11 | 4P | — | Τύπος Α | — |
RCCB applications
Typical environments where the correct residual-current protection characteristics must be verified.

Κτίρια κατοικιών
Residual-current protection for final circuits and residential distribution boards.

Βιομηχανικός αυτοματισμός
Appropriately selected RCCB types for electronic loads, drives and control-system supply circuits.

Ηλιακή ενέργεια & Αποθήκευση ενέργειας
Residual-current protection coordinated with inverter and power-conversion equipment.
RCCB Knowledge & Selection Guides
Όλα τα άρθραRCCB selection questions
Quick answers for comparing a residual-current protection family before detailed circuit verification.
Από τι προστατεύει ένα RCCB;
An RCCB detects an imbalance between outgoing and returning current and disconnects the circuit when the residual current exceeds its operating characteristics. It is used for earth-leakage protection in an appropriately designed installation.
Does an RCCB provide overload and short-circuit protection?
An RCCB is selected for residual-current protection and does not normally replace overcurrent protection. The circuit may also require an MCB, fuse or a combined RCBO according to the installation design.
What is the difference between Type AC, A, F and B RCCBs?
The type identifies the residual-current waveforms the device is designed to detect. The correct type depends on the connected equipment, applicable standards and manufacturer documentation; availability varies by VIOX series.
How should RCCB sensitivity be selected?
The rated residual operating current must match the protection objective and the applicable installation rules. Confirm the required sensitivity on the individual model page or datasheet before specification.
Can an RCCB be selected by rated current alone?
No. Rated current, pole configuration, rated residual operating current, RCCB type, circuit voltage and coordination with overcurrent protection must all be checked.