Genel Bakış
XRNT VIOX XRNT type high voltage transformer protection current limiting fuses are designed with insert installation, which is convenient for installation and removal. The 12kV 200A XRNT Transformer Protection Current Limiting Fuse is made of high-resistance metal wire and low-resistance metal wire. They are sealed in the fuse tube filled with high-purity quartz sand. The fuse tube is made of heat resistance, high-duty ceramic or epoxy glass. When a fault circuit happens and causes an arc, quartz sand will extinguishes the arc immediately.
12kV 200A XRNT Transformer Protection Current Limiting Fuse
Özellikler
- IEC60282-1
- Rated voltage 12kV and current capacity 200A for high-voltage current-limiting fuse applications.
- High interrupting performance (High Breaking Capacity) with rapid current-limiting fault clearing.
- Engineered and tested in accordance with IEC 60269 standards.
- Precision-engineered low-power-loss silver-plated contacts and high-temperature ceramic or flame-retardant housing.
- Direct OEM replacement geometry for standardized industrial, solar PV, ESS, and EV protection panels.
Teknik Özellikler
VIOX-XRNT Technical Specifications
| Model/Size | Rated Voltage (kV) | Nominal Akım (A) | Rated Drop-Out Current (kA) | Genel Boyut | |
|---|---|---|---|---|---|
| φD | L (mm) | ||||
| XRNT | 3.6 | 6.3, 10, 16, 20, 25, 31.5, 40 | 31.5 | 51 | 191 |
| XRNT | 7.2 | 6.3, 10, 16, 20, 25, 31.5, 40, 50, 63 | 31.5 | 51 | 292 |
| XRNT | 7.2 | 80, 100, 125, 160 | 31.5 | 76 | 292 |
| XRNT | 12 | 6.3, 10, 16, 20, 25, 31.5, 40 | 31.5 | 51 | 292 |
| XRNT | 12 | 50, 63, 71, 80, 100 | 31.5 | 76 | 292 |
| XRNT | 12 | 125 | 31.5 | 76 | 292 |
| XRNT | 12 | 160, 200 | 31.5 | 88 | 292 |
| XRNT | 24 | 6.3, 10, 16, 20, 25, 31.5, 40 | 31.5 | 51 | 442 |
| XRNT | 24 | 50, 63, 71, 80, 100 | 31.5 | 76 | 442 |
| XRNT | 24 | 125 | 31.5 | 76 | 442 |
| XRNT | 24 | 160 | 31.5 | 88 | 442 |
| XRNT | 40.5 | 3.15, 6.3, 10, 16, 20, 25 | 31.5 | 51 | 537 |
| XRNT | 40.5 | 31.5、40 | 31.5 | 76 | 537 |
| XRNT | 40.5 | 63 | 31.5 | 88 | 537 |
Selection & Installation Notes
- Verify system maximum voltage (12kV) and prospective short-circuit fault current before selecting the fuse link or holder rating.
- Apply ambient-temperature derating when operating inside sealed outdoor combiner boxes or high-density inverter cabinets above 40°C.
- Always de-energize circuits before replacing cylindrical, blade, or bolted fuse links, and use insulated fuse pullers for NH/NT types.
- Explore the complete VIOX Fuse & Fuse Holder catalog for matched holders, bases, and disconnectors.
SSS
What voltage and current ratings does the VIOX 12kV 200A XRNT Transformer Protection Current Limiting Fuse support?
This VIOX VIOX-XRNT series is rated for 12kV with a current rating of 200A and High Breaking Capacity breaking performance. Refer to the technical specification table above for individual part numbers and ampere steps.
Which international standards apply to VIOX 12kV 200A XRNT Transformer Protection Current Limiting Fuse?
The VIOX-XRNT series is designed and verified to IEC 60269 requirements for safe overcurrent and short-circuit protection.
Where is the VIOX 12kV 200A XRNT Transformer Protection Current Limiting Fuse typically installed?
It is engineered for high-voltage current-limiting fuse circuits, protecting cables, busbars, semiconductors, battery modules, or string feeders against thermal overload and high-energy short-circuit faults.
Can VIOX supply matched fuse holders, bases, or OEM private-label packaging?
Yes. VIOX Electric supplies matched DIN-rail fuse holders, NH/NT fuse bases, disconnectors, and OEM/ODM bulk packaging with technical datasheets upon RFQ.