VIOX ELECTRIC
Язык
Direct Factory · IEC 62852 Photovoltaic Connector Manufacturer

MC4-Compatible Solar Connectors 1000V & 1500V DC · 30A–50A IP68 Inline, T-Branch & Y-Branch Series

VIOX Electric manufactures 16 matched-pair VOPV photovoltaic connector models—spanning VOPV-01 на VOPV-07 inline connectors (up to 50 A / 1500 VDC / 10 mm²), VOPV-T3–T7 2-to-6 way multi-branch blocks, and VOPV-Y3–Y5 Y-branch assemblies with tinned copper contacts (≤ 0.5 mΩ) and UV-stabilized PPO housings.

1000V / 1500V DCInline, T-Branch & Y-Branch
30 A – 50 A2.5 / 4 / 6 / 10 mm² PV Cable
IP68 · ≤ 0.5 mΩTinned Copper · UV PPO
VIOX VOPV-03 1500V DC MC4-Compatible Solar PV Connector
01 · Complete VIOX VOPV Solar Connector Lineup

Browse Inline, T-Type & Y-Type MC4-Compatible Connectors

Filter all 16 published VOPV connector models by connection format, or scroll directly to the full engineering specification matrix below.

Complete electrical and cable specifications of all 16 VIOX VOPV MC4-compatible solar PV connectors
Модель Формат Номинальное напряжение Номинальный ток PV Cable Cross-Section Страница изделия
VOPV-07 Линейный соединитель 1000 V DC 30 A 2.5 / 4 / 6 mm² View VOPV-07 →
VOPV-06 Линейный соединитель 1500 В постоянного тока 30 A 2.5 / 4 / 6 mm² View VOPV-06 →
VOPV-05 Линейный соединитель 1000 V DC 30 A 2.5 / 4 / 6 mm² View VOPV-05 →
VOPV-04 Линейный соединитель 1000 V DC 30 A 2.5 / 4 / 6 mm² View VOPV-04 →
VOPV-03-01 Линейный соединитель 1500 В постоянного тока 50 А 10 мм² View VOPV-03-01 →
VOPV-03 Линейный соединитель 1500 В постоянного тока 30 A 2.5 / 4 / 6 / 10 mm² View VOPV-03 →
VOPV-02 Линейный соединитель 1000 V DC 30 A 2.5 / 4 / 6 mm² View VOPV-02 →
VOPV-01 Линейный соединитель 1000 V DC 30 A 2.5 / 4 / 6 mm² View VOPV-01 →
VOPV-T7 6-ходовое ответвление 1500 V IEC / 800 V UL 50 А 2.5 / 4 / 6 mm² View VOPV-T7 →
VOPV-T6 5-ходовое ответвление 1500 V IEC / 800 V UL 50 А 2.5 / 4 / 6 mm² View VOPV-T6 →
VOPV-T5 4-ходовое ответвление 1500 V IEC / 800 V UL 50 А 2.5 / 4 / 6 mm² View VOPV-T5 →
VOPV-T4 3-канальный ответвитель 1500 V IEC / 800 V UL 50 А 2.5 / 4 / 6 mm² View VOPV-T4 →
VOPV-T3 2-канальный ответвитель 1500 V IEC / 800 V UL 50 А 2.5 / 4 / 6 mm² View VOPV-T3 →
VOPV-Y5 Многоканальный Y-образный отвод 1000 V IEC / 800 V UL 30 A 2.5 / 4 / 6 mm² View VOPV-Y5 →
VOPV-Y4 Y-образное ответвление 1000 V IEC / 800 V UL 30 A 2.5 / 4 / 6 mm² View VOPV-Y4 →
VOPV-Y3 Y-образное ответвление 1000 V IEC / 800 V UL 30 A 2.5 / 4 / 6 mm² View VOPV-Y3 →
02 · Interactive PV Voltage, Cable & Topology Matcher

Match Your Solar String Voltage, Cable Gauge & Branch Format

Select your wiring topology, maximum DC string voltage, and PV cable cross-section to confirm the exact VIOX VOPV connector model and ampacity rating.

1. Connection Topology
2. System DC Voltage (Cold-Site Max Voc)
3. Solar PV Cable Cross-Section
03 · Interactive Contact-Resistance & I²R Thermal Lab

Simulate Matched Pair vs. Cross-Mated Resistance & Thermal Loss

Compare contact-pin engagement between a matched VIOX pair and a cross-mated connector mix, then slide string current to calculate real P = I²R junction heat loss.

LAB 01Matched Pair vs. Cross-Mated Pin Contact Simulator

Contact Pin & Spring-Clip Interface

LOW RESISTANCE · SAFE

IP68 EPDM Seal & Moisture Barrier

IP68 SEALED

25 A
Calculated Junction Heat Loss (P = I²R) & Sizing Check

Why Cross-Mating Causes PV Roof Fires

Mismatched pin diameters and spring tensions raise contact resistance by 10×–30×. Under 1500V DC continuous solar load, I²R heating softens housings and triggers sustained series DC arcs.

Tinned Copper + Precision Crimp

VIOX uses open-barrel tinned copper contacts engineered for dedicated hex/indent PV crimpers, locking contact resistance below 0.5 mΩ across 25-year thermal cycling.

Matched IP68 Cable-Gland Sealing

Every VOPV back-nut compresses an EPDM sealing sleeve matched to 2.5–10 mm² solar cable OD, keeping moisture and corrosion out of rooftop and ground-mount strings.

04 · Direct Factory Proof · IEC 62852 & Turnkey PV BOM

Solar Connector Quotation Drivers, 100% QC & Combiner Kitting

Consistent batch tolerances, UV-resistant UL94 V-0 PPO housings, and single-PO solar DC protection kitting for EPCs, harness assemblers, and distributors.

4 specification and OEM variables that govern VIOX MC4-compatible solar connector quotation
Specification Variable Standard Baseline High-Voltage / Multi-Branch Option Engineering & BOM Impact
1. Format & Voltage VOPV-01/02/04/05/07 1000V DC Inline (30 A) VOPV-03/06 1500V Inline, VOPV-03-01 50 A, or VOPV-T3–T7 2–6 Way Determines contact pin copper thickness, creepage distance, and mold cavity
2. Cable Size & Contact Pin 2.5 / 4 / 6 mm² standard stamped tinned copper pin 10 mm² (8 AWG) heavy-duty 50 A pin + oversized EPDM gland seal Must match exact PV cable outer diameter to maintain IP68 waterproof seal
3. Turnkey Solar Protection Kit Bulk connector pairs (polybag / export carton) Bundle VOPV 1500V PV Fuse + DC MCB + DC SPD Single-PO combiner & string BOM lowers export freight and ensures compatibility
4. OEM Branding & Tooling VIOX standard catalog marking & carton packing Private-label laser logo, retail blister/bag kits, PV crimp pliers & spanners Mixed-model carton consolidation and engineering sample sets available

1. ≤ 0.5 mΩ Contact Check

Precision tinned copper pin plating and spring-clip contact force are verified per batch to prevent thermal drift.

2. IP68 & Retention Pull QC

Mated waterproof immersion testing and mechanical locking-tab pull tests confirm zero back-out under wind/ice load.

3. UV PPO & 1500V Dielectric

Flame-retardant UL94 V-0 PPO housings undergo high-voltage withstand and UV aging validation for 25-year outdoor exposure.

Trademark & Mating Compliance Notice

MC4 is a registered trademark of Stäubli Electrical Connectors. VIOX VOPV connectors are MC4-compatible IEC 62852 photovoltaic connectors engineered to be installed as matched VIOX male-and-female pairs. For utility/EPC compliance, do not intermate unverified third-party connectors on the same string.

05 · Interactive B2B Tool · 5-Step Solar Connector RFQ Builder

Generate Your MC4-Compatible Connector RFQ in 30 Seconds

Configure connector format, DC voltage, cable gauge, tooling/kitting, and OEM branding, then copy or attach directly to the VIOX sales form.

1. Connector Format
2. Rated DC Voltage
3. PV Cable Cross-Section
4. Tooling & Solar Kitting
5. Branding & Packaging
06 · Solar Connector Engineering Knowledge Hub

MC4-Compatible Connector Selection, QC & Sourcing Guides

Technical field guides covering pin quality indicators, manufacturing QC, bulk Incoterms logistics, and solar combiner wiring.

07 · Technical & Sourcing FAQ

MC4-Compatible Solar Connector Questions

Trademark & Fit Are VIOX VOPV connectors Original MC4 products?

No. MC4 is a protected trademark of Stäubli. VIOX manufactures IEC 62852 MC4-compatible photovoltaic connectors (VOPV inline, VOPV-T, and VOPV-Y series) engineered to be mated as matched VIOX male-and-female pairs.

Cross-Mating Why should solar connectors from different brands never be cross-mated in the field?

Even when two connectors share a similar external housing profile, tiny tolerances in contact-pin plating, spring-clip geometry, and EPDM sealing rings can elevate contact resistance from ≤ 0.5 mΩ to > 5–15 mΩ.

At 15 A–30 A continuous PV string current, elevated contact resistance generates localized I²R heating that melts housings and triggers DC series arcs. Always use matched VIOX pairs with proper crimp tooling.

1000V vs 1500V Which VIOX VOPV models support 1500V DC utility solar arrays?

For 1500V DC inline terminations, specify VOPV-03 (30 A · 2.5–10 mm²), VOPV-06 (30 A · 2.5–6 mm²), or VOPV-03-01 (50 A · 10 mm² heavy-current).

For 1500V IEC parallel string combining, specify the VOPV-T3 through VOPV-T7 multi-way T-branch series rated 50 A (2-way to 6-way).

Cable Sizing Which PV cable cross-sections (mm² / AWG) fit the VOPV connector range?

Standard VOPV inline, T-branch, and Y-branch models accept 2.5 mm², 4 mm², and 6 mm² (14–10 AWG) double-insulated solar PV cable.

For high-current home-run trunks and combiner feeders using 10 mm² (8 AWG) cable, specify VOPV-03 or VOPV-03-01 (50 A rated).

Branch Types When should I choose VOPV-T multi-way branch vs. VOPV-Y branch connectors?

Choose VOPV-T3 through VOPV-T7 when combining 2 to 6 parallel strings up to 50 A at 1500V IEC in a compact rigid busbar-style branch block.

Choose VOPV-Y3, VOPV-Y4, or VOPV-Y5 for flexible 1000V IEC / 30 A rooftop string paralleling where cable-lead strain relief and tight routing clearance are preferred.

Turnkey BOM Can VIOX supply MC4-compatible connectors bundled with 1500V PV fuses, DC MCBs, and DC SPDs?

Yes. VIOX manufactures the complete solar DC protection stack—VOPV MC4-compatible connectors, VOPV 1000V–1500V gPV solar fuses, VOB3/VOB6/VOB2 DC MCBs, and VSP Solar DC SPDs—for single-PO EPC and OEM kitting.

Direct Engineering & OEM Support

Need Bulk 1000V / 1500V Solar Connectors or Harness Kitting?

Share your PV cable cross-section, voltage rating, inline or branch quantities, and packaging specs. VIOX factory engineers will prepare matched VOPV samples, datasheets, and turnkey solar protection pricing.

IEC 62852 · 1000V & 1500V DC IP68 · ≤ 0.5 mΩ Tinned Copper OEM / Private-Label Ready