Voltage Protector Manufacturer DIN-Rail 1P, 3P SYN/ASY, Auto Phase Selectors & WiFi Smart Relays (16A–125A)
Engineered for unstable grids, commercial distribution panels, motors, and OEM switchboards. VIOX builds 22 load-carrying adjustable voltage, current, leakage & kWh protectors with magnetic latching relays (≥100,000 cycles) alongside 2 control-circuit monitoring relays.
Six VIOX Voltage Protection Architectures
Compare supply topology, load current capability, wiring polarity, and relay type across our complete voltage protection portfolio.
| Series Family | VIOX Models | Supply & Current | Védelem Hatálya | Wiring Direction | Elsődleges alkalmazás |
|---|---|---|---|---|---|
| Single-Phase DIN-Rail (8) | VOPD1-63VAE, VOPD1-60-EC/63VA, VOPD1-63DK, VOPD1-40M, VOD238-VAP, VOPD1-60/60-V/63VAE-Z | AC 140–300V · 1P+N · 40A / 63A / 80A | OV, UV, OC, kWh / Prepaid, Over-Power kW, Dual-Pole L+N | Top-IN / Bottom-OUT (18mm & 36mm DIN) | Residential panels, commercial sub-boards, HVAC & sub-metering |
| Three-Phase DIN-Rail (4) | VOPD3-63VA/100VA, VOPD3-63VAS/100VAS, VOPD3-60/125, VOPD3-II | 3×220/380V AC · 3P / 3P+N · 63A / 100A / 125A | Per-phase OV/UV/OC, Phase Loss, Unbalance, Sequence, SYN/ASY Mode | VOPD3-VA: Bottom-IN / Top-OUT (check label) | 3-phase motors, industrial pumps, compressors, commercial risers |
| Auto Phase Selectors (4) | VOPD3-63VAYA/100VAYA, VOPD3-63VAY/100VAY, VOPD3-63VAEY, VOAP2-100A | 3×220V In → 1×220V Out · 63A / 100A | Auto-transfer to healthy phase on OV/UV/outage, priority return, prepaid kWh | 3-Phase Input (L1/L2/L3+N) → 1-Phase Load | Telecom racks, clinics, servers & critical 1P loads on 3P supply |
| WiFi Tuya Smart (3) | VOMPD-63LW, VOB9S-VAP (18mm), VOVA-63T (Color LCD) | AC 85–300V · 1P+N (L+N only) · 63A | Tuya WiFi App control, OV/UV/OC, kWh, 10–99mA Leakage (63LW/63T) | Top-IN / Bottom-OUT (strictly L+N, never L+L) | Remote rental management, solar inverters, smart distribution boards |
| Leakage / RTC & Plug-In (3) | VOMPD-63SL, VOMPD-63L-BAT (RTC), VOSVA-16 (EU Plug-In) | AC 140–300V · 16A Plug-In / 63A DIN | 10–99mA earth leakage, RTC battery timer, appliance-level OV/UV/OC | DIN Top-IN / Bottom-OUT · VOSVA-16 Direct EU Socket | Refrigerators, retail freezers, timed lighting & shock-sensitive circuits |
| Control Monitoring Relays (2) | VOMPD-8S (3-Phase 6A), VOMPD-AD220 (AC/DC 6A) | 3×380V AC / AC-DC 24–220V · 6A Control | Voltage window, phase sequence & asymmetry via 1CO dry contact | 18mm Control Relay → Drives External AC Contactor | MCC cabinets, ATS panels, cranes, industrial machinery >100A |
24 VIOX Voltage Protectors & Monitoring Relays
Filter by phase architecture or smart capability. Click any series card for full programmable menu codes (A0–A18 / P1–C5) and wiring instructions.
VIOX VOPD1-63VAE Single-Phase Adjustable Voltage, Current & kWh Protector (40A / 63A)
- Feszültség
- AC 140–300 V (50/60 Hz)
- Jelenlegi
- 1–63 A Adjustable
- Formátum
- 86 × 36 × 68 mm (2-Module)
- Szabvány
- CE · Auto-Reclosing
VIOX VOPD1-60-EC / VOPD1-63VA Single-Phase Dual-LED Voltage & Current Protector (40A / 63A / 80A)
- Feszültség
- AC 140–300 V (230V / 110V Opt.)
- Jelenlegi
- 40 A / 63 A / 80 A
- Formátum
- 86 × 36 × 68 mm (2-Module)
- Szabvány
- CE · 63A Latching Relay
VIOX VOPD3-63VA / VOPD3-100VA Three-Phase Per-Phase Voltage & Current Protector (63A / 100A)
- Feszültség
- 3×220/380 V AC (140–300 V L-N)
- Jelenlegi
- 63 A / 100 A Adjustable
- Formátum
- 91 × 102 × 52 mm (5-Module)
- Szabvány
- IP20 · Ui 450V · 1% Accuracy
VIOX VOPD3-63VAS / VOPD3-100VAS Three-Phase SYN / ASY Dual-Mode Voltage & Current Protector (63A / 100A)
- Feszültség
- 3×230 V (220/380 V AC)
- Jelenlegi
- 1–63 A / 1–100 A
- Formátum
- 91 × 102 × 52 mm
- Szabvány
- CE · SYN & ASY Modes
VIOX VOPD3-63VAYA / VOPD3-100VAYA Automatic Phase Selector with Current Protection (63A / 100A)
- Feszültség
- AC 3×220 V In → 1-Phase 220 V Out
- Jelenlegi
- 63 A / 100 A (3–100 A Adj.)
- Formátum
- 102 × 91 × 52 mm
- Szabvány
- LVD / EMC / RoHS · Latching Relay
VIOX VOMPD-63LW Single-Phase WiFi Tuya Smart Voltage, Current, kWh & Leakage Protector (63A)
- Feszültség
- AC 140–300 V (230 V Rated)
- Jelenlegi
- 1–63 A · Leakage 10–99 mA
- Formátum
- 95 × 45 × 68 mm
- Szabvány
- 2.4G WiFi · Tuya · L+N Cutoff
VIOX VOB9S-VAP Ultra-Slim 18mm 1P+N WiFi Smart Voltage, Current & Power Protector (1–63A)
- Feszültség
- AC 90–300 V (50/60 Hz)
- Jelenlegi
- 1–63 A · Power 1–26 kW
- Formátum
- 82 × 18 × 50 mm (1-Module)
- Szabvány
- CE · 2.4G WiFi · Tuya
VIOX VOSVA-16 16A Plug-In EU Socket Adjustable Voltage & Current Appliance Protector
- Feszültség
- AC 190–300 V (220/230 V)
- Jelenlegi
- 1–16 A Adjustable
- Formátum
- 122 × 55 × 86 mm
- Szabvány
- CE · PC Flame-Retardant
VIOX VOPD1-60 Single-Phase Fixed-Threshold Auto-Reclosing Voltage Protector (40A)
- Feszültség
- 230 V AC (Fixed 270V / 170V)
- Jelenlegi
- 40 A
- Formátum
- 35 mm-es DIN-sín
- Szabvány
- CE · Auto-Reclosing
VIOX VOPD1-60-V Single-Phase Adjustable Voltage Protector with LED Display (40A / 63A)
- Feszültség
- AC 140–300 V (230 V Rated)
- Jelenlegi
- 40 A / 63 A
- Formátum
- 35 mm-es DIN-sín
- Szabvány
- CE · Voltage-Only
VIOX VOPD1-63VAE-Z Single-Phase Voltage, Current & Over-Power (kW) Protector (63A)
- Feszültség
- 230 V AC (1P+N)
- Jelenlegi
- 63 A · Power 0.1–13.9 kW
- Formátum
- 35 mm-es DIN-sín
- Szabvány
- CE · Over-Power Cutoff
VIOX VOPD1-63DK Dual-Pole (L+N Cutoff) Adjustable Voltage & Current Protector (63A)
- Feszültség
- AC 110 V / 230 V (50/60 Hz)
- Jelenlegi
- 1–63 A Adjustable
- Formátum
- 35 mm-es DIN-sín
- Szabvány
- CE · Simultaneous L+N
VIOX VOPD1-40M Ultra-Slim 18mm 1P+N Adjustable Voltage & Current Protector (1–40A)
- Feszültség
- AC 100–300 V (110V / 230V)
- Jelenlegi
- 1–40 A Adjustable
- Formátum
- 18 mm Width (1-Module)
- Szabvány
- CE · Space-Saving DIN
VIOX VOD238-VAP / VOD238-VAP-T DIN-Rail Energy Meter with Voltage, Current & Temperature Protection (63A / 80A)
- Feszültség
- 230 V AC (50/60 Hz)
- Jelenlegi
- 1–63 A (80 A Option)
- Formátum
- 35 mm DIN-Rail Meter Style
- Szabvány
- CE · Optional -T Thermal
VIOX VOMPD-63SL Single-Phase Auto-Reclosing Voltage, Current & Earth Leakage Protector (63A)
- Feszültség
- AC 140–300 V (230 V Rated)
- Jelenlegi
- 1–63 A · Leakage Protection
- Formátum
- 35 mm-es DIN-sín
- Szabvány
- CE · Local Leakage + OVP
VIOX VOMPD-63L-BAT Multi-Function Voltage, Current, Leakage & RTC Battery-Backup Timer Protector (63A)
- Feszültség
- 230 V AC (50/60 Hz)
- Jelenlegi
- 1–63 A · Leakage + Timer
- Formátum
- 35 mm-es DIN-sín
- Szabvány
- CE · Built-In RTC Battery
VIOX VOPD3-60 / VOPD3-125 Three-Phase Fixed-Threshold Auto-Reclosing Voltage Protector (63A / 100A)
- Feszültség
- 3×220/380 V AC
- Jelenlegi
- 63 A / 100 A (Ie)
- Formátum
- 35 mm-es DIN-sín
- Szabvány
- CE · Fixed 3-Phase
VIOX VOPD3-II Three-Phase Adjustable Voltage-Only Protector (63A)
- Feszültség
- 3×220/380 V AC
- Jelenlegi
- 63 A
- Formátum
- 35 mm-es DIN-sín
- Szabvány
- CE · 3P Voltage-Only
VIOX VOPD3-63VAY / VOPD3-100VAY Automatic Phase Selector (Voltage-Only, 63A / 100A)
- Feszültség
- AC 3×220 V In → 1-Phase Out
- Jelenlegi
- 63 A / 100 A
- Formátum
- 102 × 91 × 52 mm
- Szabvány
- CE · Magnetic Latching
VIOX VOPD3-63VAEY Automatic Phase Selector with Per-Phase kWh Metering & Prepaid Cutoff (63A)
- Feszültség
- AC 3×220 V In → 1-Phase Out
- Jelenlegi
- 3–63 A Adjustable
- Formátum
- 35 mm-es DIN-sín
- Szabvány
- CE · Prepaid + Selector
VIOX VOAP2-100A 100A Three-Source Power Phase Selector with Over/Under Voltage, Current & Alarm Relay
- Feszültség
- 3×220 V AC (L+N × 3 Inputs)
- Jelenlegi
- 100 A · NC/COM/NO Alarm
- Formátum
- 35 mm-es DIN-sín
- Szabvány
- CE · Dual-Pole L+N + Buzzer
VIOX VOVA-63T Smart WiFi Metering Voltage, Current & Leakage Protector (110V / 220V · 63A)
- Feszültség
- AC 80–300 V (110V / 220V)
- Jelenlegi
- 1–63 A · 0–99999.9 kWh
- Formátum
- 84 × 36 × 65 mm (2-Module)
- Szabvány
- CE · 2.4G WiFi · Tuya
VIOX VOMPD-8S Three-Phase Voltage, Phase-Sequence & Unbalance Monitoring Relay (380V AC · 1NO+1NC)
- Feszültség
- AC 300–490 V (380 V Rated)
- Jelenlegi
- 6 A Control Contacts (1NO+1NC)
- Formátum
- 43 mm Modular DIN-Rail
- Szabvány
- CE · Non-Load Control Relay
VIOX VOMPD-AD220 Single-Phase AC/DC Voltage Monitoring Relay (50–300V · 1CO+1NC)
- Feszültség
- AC/DC 50–300 V (110–240 V)
- Jelenlegi
- 6 A Control Contacts (1CO+1NC)
- Formátum
- 35 mm-es DIN-sín
- Szabvány
- CE · AC/DC Control Relay
Interactive Voltage Protector Selector
Select your grid topology and required protection features to match the exact VIOX model, wiring polarity, and menu architecture.
Step 1 · Select Supply Topology & Duty
Step 2 · Select Feature & Current Tier
Wiring Polarity & 4 Common Commissioning Mistakes
Verify terminal feed direction before commissioning DIN-rail voltage protectors to prevent relay damage and nuisance trips.
Reversed 3-Phase Feed
Feeding top terminals on Bottom-IN VOPD3-63VA/100VA leaves internal sensing unpowered during disconnect. Always match housing IN/OUT markings.
L+L Split-Phase on WiFi
VOB9S-VAP and VOMPD-63LW require an L+N neutral reference. Never wire two 120V hot legs (L1+L2) into an L+N voltage protector.
Short Delay on HVAC
Default 30 s recovery delay is too brief for refrigerator or chiller compressors. Program A1/A4/A8 to 180–300 s to prevent locked-rotor trips.
Overloading Control Relays
VOMPD-8S and VOMPD-AD220 are 6A control monitoring relays. Pair them with a VIOX AC contactor coil rather than switching 63A loads directly.
VIOX Factory Calibration, Latching Endurance & OEM Supply
Built on automated calibration benches with flame-retardant housings and customizable distributor firmware defaults.
100% Threshold Calibration
Every unit undergoes automated over-voltage, under-voltage, and over-current trip verification before carton sealing (≤1% full-scale accuracy on VOPD3).
Magnetic Latching Relays
High-capacity latching relays hold closed without continuous coil heat, keeping self-consumption ≤2 W and rated endurance ≥100,000 cycles.
OEM Firmware & Branding
Custom factory default thresholds (110V/220V/230V), laser-etched private labels, and multilingual manuals available for distributor volume orders.
CE / LVD / EMC / RoHS
Flame-retardant PA66 housings, IP20 finger-safe tunnel terminals, and compliance with EU Low Voltage (2014/35/EU) and EMC (2014/30/EU) directives.
Build Your Voltage Protector RFQ Brief
Configure supply type, current rating, smart/leakage features, and OEM requirements to prefill our engineering quote form in one click.
1. Supply & Architecture
2. Load Current Tier
3. Smart, Leakage & Metering Options
4. Supply / OEM Scope
Voltage Protector Engineering FAQ
Direct answers on Top-IN vs. Bottom-IN wiring, SYN/ASY 3-phase modes, auto phase selection, L+N WiFi limits, and HVAC delay tuning.
Vezetékek Are all VIOX DIN-rail voltage protectors wired Top-IN and Bottom-OUT?
No. Single-phase DIN-rail models (VOPD1-63VAE, VOPD1-60-EC, VOMPD-63LW, VOB9S-VAP) use Top-IN, Bottom-OUT wiring ("over-entering down-out").
Three-phase VOPD3-63VA and VOPD3-100VA wire Bottom-IN (supply) and Top-OUT (load). Always check the IN/OUT terminal markings printed on the housing before energizing.
3-Phase Modes When should I choose SYN (Synchronous) vs. ASY (Asynchronous) mode on VOPD3-63VAS / 100VAS?
Use SYN (Synchronous) mode for 3-phase motors, pumps, and compressors where losing one phase causes winding burnout — all three relays open together on any single-phase fault.
Use ASY (Asynchronous) mode for commercial buildings or multi-apartment boards feeding independent single-phase loads, so a fault on L1 disconnects only L1 while L2 and L3 keep running.
Phase Selector How does an Automatic Phase Selector (VOPD3-63VAYA / VOAP2-100A) protect critical single-phase loads?
It connects three incoming phases (L1, L2, L3 + N) and feeds a single-phase output load up to 63 A or 100 A via built-in magnetic latching relays.
If the active priority phase suffers over-voltage, under-voltage, or outage, the selector automatically transfers the load to a healthy backup phase and optionally returns to the priority phase once stable.
WiFi & Split-Phase Can I wire VOB9S-VAP or VOMPD-63LW on a 240V L+L split-phase circuit without neutral?
No. VIOX single-phase WiFi protectors (VOB9S-VAP, VOMPD-63LW, VOVA-63T) require an L+N single-phase supply (AC 85–300 V / 140–300 V).
Connecting two hot legs (L1+L2 without neutral) violates the internal sensing and relay architecture and will damage the unit. For two-wire dual-pole disconnection on L+N systems, specify VOPD1-63DK.
Védelem Hatálya What is the difference between a load-carrying Voltage Protector and a Voltage Monitoring Relay?
Load-carrying voltage protectors (VOPD1, VOPD3, VOMPD-63LW, VOSVA-16) switch 16 A to 125 A loads directly through an internal magnetic latching relay.
Voltage monitoring relays (VOMPD-8S, VOMPD-AD220) carry 6 A–10 A dry control contacts (1CO / 1NO+1NC) that drive an external AC contactor coil or shunt trip for heavy industrial switchgear.
HVAC & Compressors What power-on and recovery delay should I set for refrigerators, chillers, and HVAC compressors?
Factory default recovery delay is typically 30 seconds (adjustable 1–500 s). For refrigeration compressors and split AC units, set power-on delay (A1/P1) and fault recovery delay (A4/A8) to 180–300 seconds so refrigerant head pressure equalizes before restart.
Sourcing DIN-Rail Voltage Protectors or Auto Phase Selectors?
Get Direct Factory Pricing.
Share your target current tier (16A–125A), voltage standard (110V/230V/380V), WiFi/leakage requirements, or private-label volume. VIOX engineers respond within 24 hours.
Request Voltage Protector Quote