You’re comparing two MCCBs with identical current ratings—both are 100A, three-pole devices. But the voltage specifications read differently: one shows “Ue 400V, Ui 690V, Uimp 8kV” while the other lists “Ue 690V, Ui 800V, Uimp 6kV.” Which one fits your 400V three-phase system? Can you safely use the first breaker even though its Ue matches your system voltage but the Uimp is different?

These three voltage parameters—Ue, Ui, and Uimp—appear on every electrical equipment datasheet from MCCBs and contactors များ ရန် relay များ နှင့် terminal လုပ်ကွက်များ. But confusion about what they actually mean leads to under-specified equipment that fails prematurely, over-specified components that waste budget, and compliance issues during project approval.

The problem isn’t just reading three numbers. Each rating tests a different electrical stress: steady-state operation, insulation integrity, and transient surge withstand. They’re governed by different IEC standards, verified through different test procedures, and serve distinct roles in equipment selection. Treating them as interchangeable—or worse, ignoring two of them—creates real safety and reliability risks.

This guide decodes all three voltage ratings with precision. You’ll learn exactly what Ue, Ui, and Uimp measure, which IEC tests validate each parameter, how they relate to insulation coordination standards, and most importantly—which rating matters for which specification decision. By the end, you’ll read equipment datasheets with confidence and select components that match both your system voltage and the complete electrical stress profile your installation faces.

Ue, Ui နှင့် Uimp ကိုပြသသည့် ဗို့အားအဆင့်သတ်မှတ်ချက်သုံးခု၏ အကျဉ်းချုပ်ပုံ
Figure 1: Visual overview of the three voltage ratings and their relationships. Ue (Rated Operational Voltage) defines normal operation, Ui (Rated Insulation Voltage) determines insulation design, and Uimp (Rated Impulse Withstand Voltage) validates surge protection capability. Understanding all three is essential for proper equipment specification. 

What is Ue (Rated Operational Voltage)?

Ue အကြောင်းရင်းက rated operational voltage—the voltage at which electrical equipment is designed to operate under normal, undisturbed conditions. This is the number you match to your system’s nominal voltage when selecting MCCBs, contactors, relays, or other control gear.

In IEC 60947 terminology, Ue defines the equipment’s application voltage domain. It works in conjunction with two other critical parameters: Ie (rated operational current) and utilization category (like AC-3 for motors or AC-23 for mixed loads). Together, these three specifications describe the device’s operational performance envelope.

What Ue Actually Tests

Ue doesn’t correspond to a specific standalone test voltage. Instead, it establishes the reference voltage for performance testing:

  • Operational endurance tests: Equipment must complete rated operational cycles (making and breaking rated current) at Ue without failure
  • Temperature rise verification: At rated current and operational voltage, device temperatures must stay within limits
  • Performance coordination: Manufacturers declare current-switching capability, short-circuit performance, and coordination data at specific Ue values

For a contactor rated Ue 400V AC-3 with Ie 95A, that means it has been tested to switch 95A inductive motor loads at 400V for its declared mechanical and electrical endurance.

Typical Ue Values for Industrial Equipment

Standard Ue ratings follow common system voltages:

  • 230V / 240V AC: Single-phase European and international systems
  • 400V / 415V AC: Three-phase European, Asian, and many industrial systems
  • 480V AC: North American three-phase industrial systems
  • 690V AC: High-voltage industrial applications, mining equipment
  • 24V / 48V / 110V DC: Control circuits, automation systems, battery-backed installations

You select equipment where the declared Ue matches or exceeds your system’s nominal voltage. A device rated Ue 690V can operate in a 400V system (it’s overrated for voltage), but a device rated Ue 230V cannot be used in a 400V application—it’s under-specified.

The Ue-Ie-Category Relationship

Ue never exists in isolation. An MCCB might show Ue 400V with multiple Ie ratings (40A, 63A, 100A) depending on frame size and thermal trip settings. A contactor might list different Ie values at different Ue levels—for example, Ie 95A at Ue 400V but only Ie 80A at Ue 690V, because higher voltage stresses the contacts during arc interruption.

Always verify all three specifications. A device rated for your voltage but wrong utilization category can fail even if the Ue matches perfectly.

တည်ငြိမ်သော AC လှိုင်းပုံစံကိုပြသသည့် MCCB လည်ပတ်ဗို့အားအသုံးချမှုဥပမာ
Figure 2: Ue (Rated Operational Voltage) in context. This diagram shows normal 50/60 Hz AC operation at system nominal voltage. Ue defines the voltage at which equipment performs its rated switching and endurance capabilities under continuous steady-state conditions.

What is Ui (Rated Insulation Voltage)?

Ui အကြောင်းရင်းက rated insulation voltage—the voltage reference used to determine dielectric test levels and minimum creepage distances. Unlike Ue (which describes operational performance), Ui defines the equipment’s insulation capability. It’s not a permissible operating voltage; it’s a design reference that ensures adequate insulation strength.

အခြေခံစည်းမျဉ်း Ue must never exceed Ui. Equipment datasheets show this relationship explicitly—a contactor rated Ue 400V will typically show Ui 690V or 800V, meaning it can operate at any voltage up to 400V while maintaining insulation designed for 690V or 800V stress levels.

What Ui Actually Tests: Dielectric Strength

Ui determines the power-frequency dielectric withstand test voltage. This test verifies that insulation can withstand sustained electrical stress without breakdown:

  • Test voltage: Typically 2 × Ui + 1000V for equipment with Ui ≤ 690V (per IEC 60947-1)
  • စမ်းသပ်ကာလ: 60 seconds (1 minute of sustained AC voltage)
  • Test frequency: 50 Hz or 60 Hz AC (power frequency)
  • Pass criteria: No disruptive discharge, no breakdown, creepage current within specified limits

For example, terminal blocks rated Ui 690V undergo dielectric testing at approximately 2,380V AC for one minute. This simulates years of insulation aging and stress condensed into a single controlled test.

Why Ui Exceeds Ue: The Safety Margin

Electrical equipment experiences voltage stress beyond nominal levels:

  • Transient overvoltages: Switching surges, capacitor bank operations
  • System voltage variations: Grid fluctuations, generator regulation issues
  • Insulation aging: စိုထိုင်းဆ၊ ညစ်ညမ်းမှု၊ အပူချိန်ပြောင်းလဲမှုများသည် အချိန်ကြာလာသည်နှင့်အမျှ လျှပ်ကာကို ယိုယွင်းစေသည်။
  • ဘေးကင်းရေး အနားသတ်: IEC စံနှုန်းများသည် လည်ပတ်ဗို့အားထက် ပိုမိုမြင့်မားသော ဖိအားအတွက် ဒီဇိုင်းထုတ်ထားသော လျှပ်ကာလိုအပ်သည်။

400V စနစ်သည် 400V အတိအကျကို အဆက်မပြတ်မြင်ခဲသည်။ ဗို့အားသည် ပုံမှန်အခြေအနေများတွင် ±10% ခန့် ပြောင်းလဲနိုင်ပြီး ယာယီဖြစ်ရပ်များသည် ၎င်းကို ပိုမိုမြင့်မားစေသည်။ Ui သည် Ue ထက် သိသိသာသာမြင့်မားသော စက်ပစ္စည်းများကို သတ်မှတ်ခြင်းသည် စက်ပစ္စည်း၏ ဝန်ဆောင်မှုသက်တမ်းတစ်လျှောက်လုံး လျှပ်ကာ၏ ခိုင်ခံ့မှုကို သေချာစေသည်။.

Ui နှင့် Creepage အကွာအဝေး လိုအပ်ချက်များ

Ui သည် အနည်းဆုံးကို တိုက်ရိုက်ဆုံးဖြတ်သည်။ creepage အကွာအဝေးများ—လျှပ်ကာမျက်နှာပြင်တစ်လျှောက် တိုင်းတာသော လျှပ်ကူးပစ္စည်းများကြား အတိုဆုံးလမ်းကြောင်း။ IEC 60664-1 ဇယားများသည် လိုအပ်သော creepage ကို အခြေခံ၍ သတ်မှတ်သည်-

  • အဆင့်သတ်မှတ်ထားသော လျှပ်ကာဗို့အား (Ui)
  • လေထုညစ်ညမ်းမှုဒီဂရီ (ညစ်ညမ်းမှုအဆင့်- သန့်ရှင်း၊ ပုံမှန်၊ လျှပ်ကူးနိုင်သော)
  • လျှပ်ကာပစ္စည်းအုပ်စု (ခြေရာခံခြင်းကို ခံနိုင်ရည်- I, II, IIIa, IIIb)

Ui မြင့်လေ creepage လိုအပ်ချက် ပိုများလေဖြစ်သည်။ Ui 1000V အတွက် terminal block များသည် Ui 400V block များထက် နေရာပိုလိုအပ်သည်၊ နှစ်ခုစလုံးသည် တူညီသော 400V စနစ်တွင် လည်ပတ်နေလျှင်ပင်။ ၎င်းသည် ရုပ်ပိုင်းဆိုင်ရာအရွယ်အစားနှင့် terminal သိပ်သည်းဆကို ထိခိုက်စေသည်။.

အသုံးများသော Ui တန်ဖိုးများ

Low-voltage စက်ပစ္စည်းများအတွက် စံ Ui အဆင့်သတ်မှတ်ချက်များ-

  • 300V: Light-duty ထိန်းချုပ်အစိတ်အပိုင်းများ၊ ဗို့အားနိမ့်သော အသုံးချမှုများ
  • 500V / 690V: 400V/480V စနစ်များတွင် စက်မှု MCCB များ၊ contactor များ၊ relay များအတွက် အသုံးအများဆုံး
  • 800V / 1000V: လိုအပ်ချက်မြင့်မားသော အသုံးချမှုများအတွက် လျှပ်ကာပိုမိုမြင့်မားခြင်း၊ ဗို့အားအကွာအဝေးကို တိုးချဲ့ခြင်း

ရွေးချယ်ထားသော စက်ပစ္စည်းသည် သင်၏ မျှော်မှန်းထားသော စနစ်ဗို့အား အမြင့်ဆုံးထက် Ui ≥ ရှိမရှိ အမြဲစစ်ဆေးပါ။ 480V စနစ်အတွက် Ui 500V ပါသော အစိတ်အပိုင်းများကို ရွေးချယ်ခြင်းသည် အနည်းဆုံးအနားသတ်ကို ပေးစွမ်းနိုင်ပြီး Ui 690V သို့မဟုတ် 800V သည် ရေရှည်တည်ငြိမ်မှုကို ပိုမိုကောင်းမွန်စေသည်။.

Uimp (Rated Impulse Withstand Voltage) ဆိုသည်မှာ အဘယ်နည်း။

Uimp အကြောင်းရင်းက rated impulse withstand voltage—လျှပ်ကာပျက်စီးခြင်းမရှိဘဲ စံသတ်မှတ်ထားသော ယာယီ overvoltage impulse များခံရသောအခါ စက်ပစ္စည်းသည် ခံနိုင်ရည်ရှိသော အထွတ်အထိပ်ဗို့အားတန်ဖိုး။ Ui သည် ပါဝါကြိမ်နှုန်း dielectric ခိုင်ခံ့မှုကို စမ်းသပ်နေစဉ် Uimp သည် လျှပ်စီးလက်ခြင်း၊ ပြောင်းခြင်းဖြစ်ရပ်များနှင့် grid အနှောင့်အယှက်များမှ လျင်မြန်ပြီး စွမ်းအင်မြင့်မားသော လှိုင်းများကို ရှင်သန်နိုင်စွမ်းကို အတည်ပြုသည်။.

Uimp ကို kilovolts (kV) အထွတ်အထိပ်ဖြင့် ဖော်ပြပြီး စံသတ်မှတ်ထားသော impulse waveform ကို အသုံးပြုသည်- 1.2/50 μs (အထွတ်အထိပ်သို့ 1.2 microsecond တက်ချိန်၊ တန်ဖိုးတစ်ဝက်သို့ 50 microsecond ကျဆင်းချိန်)။ ဤ waveform သည် လျှပ်စီးကြောင့်ဖြစ်သော လှိုင်းများနှင့် ပြောင်းလဲနေသော ယာယီများ၏ လျှပ်စစ်လက်မှတ်ကို ပုံဖော်သည်။.

Uimp အမှန်တကယ် စမ်းသပ်ခြင်း- Surge Immunity

impulse withstand စမ်းသပ်မှုသည် စက်ပစ္စည်းအား ဗို့အားမြင့် ယာယီ pulse များဖြင့် စမ်းသပ်သည်-

  • စမ်းသပ် waveform: 1.2/50 μs ဗို့အား impulse (စံ IEC ပုံသဏ္ဍာန်)
  • Test voltage: စက်ပစ္စည်း၏ ကြေငြာထားသော Uimp (6 kV, 8 kV, 12 kV, etc.)
  • စမ်းသပ်မှုလုပ်ထုံးလုပ်နည်း: ဝင်ရိုးစွန်းနှစ်ခု (အပေါင်းနှင့် အနှုတ်) ဖြင့် အသုံးပြုထားသော impulse အများအပြား
  • impulse များကြားကာလ: အနည်းဆုံး 1 စက္ကန့်
  • Pass criteria: flashover မရှိ၊ လျှပ်ကာပျက်စီးခြင်းမရှိ၊ clearances များ ယိုယွင်းခြင်းမရှိ

Uimp 8 kV အဆင့်သတ်မှတ်ထားသော circuit breaker အတွက် စမ်းသပ်အင်ဂျင်နီယာများသည် အတွင်းပိုင်း clearances နှင့် လျှပ်ကာသည် ဤယာယီဖိအားများကို ပျက်စီးခြင်းမရှိဘဲ ခံနိုင်ရည်ရှိကြောင်း အတည်ပြုရန်အတွက် 8,000-volt အထွတ်အထိပ် impulse များကို ထပ်ခါထပ်ခါ အသုံးပြုသည်။.

Overvoltage အမျိုးအစား ဆက်သွယ်မှု

Uimp တန်ဖိုးများသည် ကျပန်းမဟုတ်ပါ—၎င်းတို့ကို overvoltage အမျိုးအစားများ IEC 60664-1 တွင် သတ်မှတ်ထားသည်။ ဤအမျိုးအစားများသည် ယာယီ overvoltage များသို့ ထိတွေ့မှုဖြင့် တပ်ဆင်မှုများကို အမျိုးအစားခွဲခြားသည်-

  • အမျိုးအစား I: ယာယီထိတွေ့မှု လျော့နည်းသော စက်ပစ္စည်း (ကာကွယ်ထားသော အီလက်ထရွန်နစ်ဆားကစ်များ)
  • အမျိုးအစား II: အသုံးအဆောင်ပစ္စည်းများနှင့် သယ်ဆောင်ရလွယ်ကူသော စက်ပစ္စည်းများ (ပုံမှန်လူနေအိမ်ဝန်များ)
  • အမျိုးအစား III: တပ်ဆင်ထားသော တပ်ဆင်မှုများ (ဖြန့်ဖြူးရေး panel များ၊ စက်မှုစက်ယန္တရားများ)
  • အမျိုးအစား IV: တပ်ဆင်မှု၏ မူလအစ (ဝန်ဆောင်မှုဝင်ပေါက်၊ utility meter များ၊ overhead လိုင်းများ)

အမျိုးအစားမြင့်လေ ယာယီပိုမိုပြင်းထန်လေဖြစ်သည်။ IEC 60664-1 ဇယားများသည် စနစ် nominal ဗို့အားများကို အမျိုးအစားတစ်ခုစီအတွက် လိုအပ်သော impulse withstand အဆင့်များနှင့် မြေပုံဆွဲသည်။ 400V သုံးဆင့်စနစ်အတွက်-

  • အမျိုးအစား II: Uimp 2.5 kV ပုံမှန်
  • အမျိုးအစား III: Uimp 6 kV ပုံမှန်
  • အမျိုးအစား IV: Uimp 8 kV ပုံမှန်

တပ်ဆင်ထားသော ဖြန့်ဖြူးရေးစနစ်များ (အမျိုးအစား III) တွင် တပ်ဆင်ထားသော စက်မှုပစ္စည်းများသည် နံရံပလပ်ပေါက်များ (အမျိုးအစား II) တွင် ပလပ်ထိုးထားသော အသုံးအဆောင်ပစ္စည်းများထက် Uimp ပိုမိုမြင့်မားရန် လိုအပ်သည်၊ နှစ်ခုစလုံးသည် တူညီသော nominal ဗို့အားတွင် လည်ပတ်နေသော်လည်း။.

စက်မှုပစ္စည်းများအတွက် ပုံမှန် Uimp တန်ဖိုးများ

Low-voltage switchgear နှင့် ထိန်းချုပ်ကိရိယာများအတွက် စံ Uimp အဆင့်သတ်မှတ်ချက်များ-

  • 4 kV: အမျိုးအစားနိမ့်သော အသုံးချမှုများ၊ လူနေအိမ်သုံးပစ္စည်းများ
  • 6 kV: ပြည်တွင်း/လူနေအိမ် MCCB များ၊ အမျိုးအစား II/III စက်ပစ္စည်းများအတွက် အသုံးများသည်။
  • 8 kV: စက်မှု MCCB များ၊ contactor များ၊ အမျိုးအစား III/IV တပ်ဆင်ထားသော တပ်ဆင်မှုများအတွက် စံ
  • 12 kV: လိုအပ်ချက်မြင့်မားသော စက်မှုအသုံးချမှုများ၊ utility-grade စက်ပစ္စည်းများ၊ ထိတွေ့မှုမြင့်မားသော တည်နေရာများ

စက်ပစ္စည်းဒေတာစာရွက်များသည် ရည်ရွယ်ထားသော တပ်ဆင်မှုအမျိုးအစားနှင့် ကိုက်ညီသော Uimp တန်ဖိုးများကို ပုံမှန်အားဖြင့် ပြသသည်။ စက်မှုအဆင့် အစိတ်အပိုင်းများသည် ပုံမှန်အားဖြင့် 8 kV သို့မဟုတ် ထို့ထက်မြင့်မားပြီး လူနေအိမ်သုံးပစ္စည်းများသည် 4-6 kV ကို ပြသနိုင်သည်။.

Uimp အရေးပါရသည့်အကြောင်းရင်း- လက်တွေ့ကမ္ဘာ လှိုင်းဖြစ်ရပ်များ

လျှပ်စစ်စနစ်များသည် ယာယီ overvoltage များကို ပုံမှန်ရင်ဆိုင်နေရသည်-

  • မိုးကြိုးပစ်တယ်။: တိုက်ရိုက် သို့မဟုတ် အနီးအနားရှိ လျှပ်စီးလက်ခြင်းသည် ဖြန့်ဖြူးရေးကွန်ရက်များထဲသို့ ဗို့အားမြင့် လှိုင်းများကို ဖြစ်ပေါ်စေသည်။
  • ပြောင်းလဲခြင်းလုပ်ငန်းများကြီးမားသောဝန်များ၊ capacitor ဘဏ်များ သို့မဟုတ် ထရန်စဖော်မာများကို ဖွင့်/ပိတ်ခြင်းသည် ဗို့အားမြင့်တက်မှုကို ဖြစ်စေသည်။
  • ဓာတ်အားလိုင်း ချို့ယွင်းချက်များချို့ယွင်းချက်ရှင်းလင်းခြင်းနှင့် ပြန်လည်ပိတ်ခြင်းလုပ်ငန်းများသည် ယာယီဖြစ်ပေါ်စေသည်။
  • မော်တာစတင်ခြင်းလျှပ်ကူးဝန်ပြောင်းခြင်းသည် ဒေသအလိုက် ဗို့အားမြင့်တက်မှုကို ဖြစ်စေသည်။

လုံလောက်သော Uimp မရှိသော စက်ပစ္စည်းများသည် မမျှော်လင့်ဘဲ ပျက်ကွက်တတ်သည်—တစ်ခါတစ်ရံ မိုးကြိုးမုန်တိုင်းပြီးနောက် ချက်ချင်းပင်၊ တစ်ခါတစ်ရံ လပေါင်းများစွာကြာအောင် စုပုံနေသော လှိုင်းဒဏ်ကြောင့် လျှပ်ကာအားနည်းသွားပြီးနောက် ပျက်ကွက်တတ်သည်။ သင့်လျော်သော Uimp သတ်မှတ်ချက်သည် စက်ပစ္စည်းသည် ၎င်း၏ တပ်ဆင်တည်နေရာနှင့် အမျိုးအစားအတွက် သီးခြားယာယီပတ်ဝန်းကျင်တွင် ရှင်သန်ကြောင်း သေချာစေသည်။.

မတူညီသော စမ်းသပ်နည်းလမ်းများနှင့် လှိုင်းပုံစံများကိုပြသသည့် Ui နှင့် Uimp စမ်းသပ်မှု နှိုင်းယှဉ်ချက်
ပုံ ၃- Ui နှင့် Uimp အကြား စမ်းသပ်နည်းလမ်း နှိုင်းယှဉ်ချက်။ Ui စမ်းသပ်ခြင်းသည် ပါဝါကြိမ်နှုန်း လျှပ်ကာအားကို အတည်ပြုရန်အတွက် စက္ကန့် ၆၀ ကြာအောင် စဉ်ဆက်မပြတ် 50/60 Hz AC ဗို့အားကို အသုံးပြုသည်။ Uimp စမ်းသပ်ခြင်းသည် ယာယီခံနိုင်ရည်စွမ်းရည်ကို အတည်ပြုရန်အတွက် မြန်နှုန်းမြင့် 1.2/50 μs လှိုင်းများကို အသုံးပြုသည်။ အဆင့်သတ်မှတ်ချက်တစ်ခုစီသည် အခြေခံအားဖြင့် မတူညီသော လျှပ်စစ်ဖိအားများကို စမ်းသပ်သည်။.

အဓိက ကွာခြားချက်များ- Ue vs Ui vs Uimp

ဤဗို့အားအဆင့်သတ်မှတ်ချက် သုံးခုသည် အခြေခံအားဖြင့် မတူညီသော လျှပ်စစ်ဖိအားများကို တိုင်းတာသည်။ ၎င်းတို့၏ ကွဲပြားခြားနားမှုများကို နားလည်ခြင်းသည် သတ်မှတ်ချက်အမှားများကို ကာကွယ်ပေးပြီး စက်ပစ္စည်းများကို အမှန်တကယ် လည်ပတ်မှုအခြေအနေများနှင့် ကိုက်ညီစေရန် ကူညီပေးသည်။.

လည်ပတ်မှု vs. လျှပ်ကာ vs. လှိုင်း- မတူညီသော မေးခွန်းများ

အဆင့်သတ်မှတ်ချက်တစ်ခုစီသည် သီးခြားဒီဇိုင်းမေးခွန်းတစ်ခုကို ဖြေဆိုသည်-

  • Ue (လည်ပတ်ဗို့အား)“ပုံမှန်၊ စဉ်ဆက်မပြတ် အခြေအနေများအောက်တွင် ဤကိရိယာသည် မည်သည့်စနစ်ဗို့အားဖြင့် လည်ပတ်နိုင်သနည်း။”
  • Ui (လျှပ်ကာဗို့အား)“ဤကိရိယာ၏ လျှပ်ကာအားနှင့် လျှပ်တွန်းအကွာအဝေးကို မည်သည့်ဗို့အားကိုးကားချက်က ဆုံးဖြတ်သနည်း။”
  • Uimp (လှိုင်းဒဏ်ခံနိုင်သော ဗို့အား)“လျှပ်ကာပျက်စီးခြင်းမရှိဘဲ ဤကိရိယာသည် မည်သည့်အထွတ်အထိပ် ယာယီဗို့အားကို ခံနိုင်ရည်ရှိသနည်း။”

၎င်းတို့သည် အပြန်အလှန် အစားထိုး၍မရသော ဖြည့်စွက်စာများဖြစ်သည်။ Ui ကို Ue အတွက် အစားထိုး၍မရသလို မြင့်မားသော Uimp သည် မလုံလောက်သော Ue ကိုလည်း မလျော်ကြေးပေးနိုင်ပါ။ သုံးခုစလုံးသည် သင်၏အသုံးချမှုလိုအပ်ချက်များနှင့် ကိုက်ညီရမည်။.

စမ်းသပ်နည်းလမ်း ကွာခြားချက်များ

အဆင့်သတ်မှတ်ချက် စမ်းသပ်မှုအမျိုးအစား စမ်းသပ်ဗို့အား ကြာချိန် ၎င်းသည် အဘယ်အရာကို အတည်ပြုသနည်း
Ue လည်ပတ်မှုစွမ်းဆောင်ရည် စမ်းသပ်မှုများ စနစ်ပုံမှန်ဗို့အား သံသရာထောင်ပေါင်းများစွာ ပြောင်းနိုင်စွမ်း၊ ခံနိုင်ရည်၊ အပူချိန်မြင့်တက်ခြင်း
Ui ပါဝါကြိမ်နှုန်း လျှပ်ကာခံနိုင်ရည် ~2 × Ui + 1000V AC စက္ကန့် ၆၀ စဉ်ဆက်မပြတ် AC ဖိအားကို ခံနိုင်ရည်ရှိသော လျှပ်ကာသမာဓိ
Uimp လှိုင်းဒဏ်ခံနိုင်ရည် စမ်းသပ်မှု အဆင့်သတ်မှတ်ထားသော လှိုင်း kV အထွတ်အထိပ် မိုက်ခရိုစက္ကန့် (ရိုက်ချက်များစွာ) မြန်နှုန်းမြင့် ယာယီလှိုင်းများကို ခံနိုင်ရည်ရှိသော ရှင်းလင်းရေးလုံလောက်မှု

Ui စမ်းသပ်မှုများသည် တစ်မိနစ်ကြာအောင် စဉ်ဆက်မပြတ် 50/60 Hz AC ကို အသုံးပြုသည်—လျှပ်ကာပေါ်တွင် နှေးကွေးသော၊ ကြိတ်ခွဲသည့် ဖိအားတစ်ခုဖြစ်သည်။ Uimp စမ်းသပ်မှုများသည် 1.2/50 μs လှိုင်းများကို အသုံးပြုသည်—ရှင်းလင်းရေးများနှင့် လေဟာနယ်များကို မတူညီစွာ ဖိအားပေးသည့် မြန်ဆန်သော၊ ထက်မြက်သော ဗို့အားမြင့်တက်မှုများဖြစ်သည်။ စမ်းသပ်မှုတစ်ခု အောင်မြင်ခြင်းသည် အခြားတစ်ခုကို အောင်မြင်ကြောင်း အာမမခံပါ။.

ဗို့အားပမာဏ ဆက်စပ်မှုများ

ပုံမှန်စက်ပစ္စည်းသည် သီးခြားဗို့အားအဆင့်ကို ပြသသည်-

Ue ≤ Ui < Uimp

ဥပမာ- 400V စနစ်အတွက် စက်မှု MCCB တစ်ခုသည် ဤသို့ပြသနိုင်သည်-

  • Ue = 400V (လည်ပတ်ဗို့အားသည် စနစ်နှင့်ကိုက်ညီသည်)
  • Ui = 690V (ပိုမိုမြင့်မားသော ဖိအားအတွက် ဒီဇိုင်းထုတ်ထားသော လျှပ်ကာ)
  • Uimp = 8 kV (အမျိုးအစား III တပ်ဆင်မှုများအတွက် လှိုင်းဒဏ်ခံနိုင်ရည်)

ပမာဏအစီအစဥ်ကို သတိပြုပါ- Ue နှင့် Ui သည် ဗို့အားရာဂဏန်းတွင် ရှိပြီး Uimp သည် ဗို့အားထောင်ဂဏန်းသို့ ခုန်တက်သွားသည်။ ၎င်းသည် တည်ငြိမ်သော လည်ပတ်မှုနှင့် နှိုင်းယှဉ်ပါက ယာယီလှိုင်းများ၏ မတူညီသော သဘောသဘာဝကို ထင်ဟပ်စေသည်။.

မည်သည့်အဆင့်သတ်မှတ်ချက်က မည်သည့်ဆုံးဖြတ်ချက်ကို အုပ်ချုပ်သနည်း။

မတူညီသော သတ်မှတ်ချက်ဆုံးဖြတ်ချက်များသည် မတူညီသော အဆင့်သတ်မှတ်ချက်များပေါ်တွင် မူတည်သည်-

ဆုံးဖြတ်ရန် Ue ကိုသုံးပါ-

  • စနစ်လိုက်ဖက်ညီမှု (စက်ပစ္စည်းသည် သင်၏ပုံမှန်ဗို့အားနှင့် ကိုက်ညီပါသလား)
  • လက်ရှိအဆင့်သတ်မှတ်ချက် ညှိနှိုင်းမှု (သတ်မှတ်ထားသော Ue အဆင့်များတွင် ကြေငြာထားသော Ie တန်ဖိုးများ)
  • အသုံးချမှုအမျိုးအစား အကျုံးဝင်မှု (AC-3, AC-23, စသည်)
  • အပြိုင်/အဆက်လိုက် ဖွဲ့စည်းမှုများ (ဗို့အားမျှဝေခြင်းဆိုင်ရာ ထည့်သွင်းစဉ်းစားမှုများ)

အတည်ပြုရန် Ui ကိုသုံးပါ-

  • လုံလောက်သော လျှပ်ကာဘေးကင်းလုံခြုံမှုအနားသတ် (Ui သည် Ue ထက် သိသိသာသာ ကျော်လွန်သင့်သည်)
  • ညစ်ညမ်းမှုဒီဂရီအတွက် လျှပ်တွန်းအကွာအဝေး လိုအပ်ချက်များနှင့်အညီ လိုက်နာမှု
  • သင်၏ပတ်ဝန်းကျင်တွင် ရေရှည်လျှပ်ကာ ယုံကြည်စိတ်ချရမှု
  • ဗို့အားအကွာအဝေးများတစ်လျှောက် စက်ပစ္စည်းသင့်လျော်မှု (ကိရိယာတစ်ခု၊ အသုံးချမှုများစွာ)

သေချာစေရန် Uimp ကိုသုံးပါ-

  • တပ်ဆင်မှု ဗို့အားပိုလျှံမှုအမျိုးအစားအတွက် ယာယီလှိုင်းကာကွယ်မှု
  • အထက်ပိုင်း လှိုင်းကာကွယ်ရေးကိရိယာများနှင့် ညှိနှိုင်းမှု
  • ထိတွေ့မှုမြင့်မားသော တည်နေရာများအတွက် လုံလောက်သော ရှင်းလင်းရေးဒီဇိုင်း
  • လျှပ်ကာညှိနှိုင်းမှုစံနှုန်းများနှင့်အညီ လိုက်နာမှု (IEC 60664-1)
အဓိပ္ပါယ်များ၊ စမ်းသပ်နည်းလမ်းများနှင့် အသုံးချပရိုဂရမ်များကိုပြသသည့် ဗို့အားအဆင့်သတ်မှတ်ချက်များ နှိုင်းယှဉ်ဇယား
ပုံ ၄- Ue, Ui နှင့် Uimp တို့၏ အမြန်ကိုးကားချက် နှိုင်းယှဉ်ချက်။ ဤဇယားသည် ဗို့အားအဆင့်သတ်မှတ်ချက် သုံးခုကြားရှိ အဓိကကွဲပြားခြားနားမှုများကို အကျဉ်းချုပ်ဖော်ပြထားပြီး အင်ဂျင်နီယာများသည် မည်သည့်အဆင့်သတ်မှတ်ချက်က သီးခြားသတ်မှတ်ချက်ဆုံးဖြတ်ချက်များကို အုပ်ချုပ်သည်ကို လျင်မြန်စွာ ခွဲခြားသတ်မှတ်နိုင်ရန် ကူညီပေးသည်။ စက်ပစ္စည်းသတ်မှတ်ချက် အပြည့်အစုံအတွက် သုံးခုစလုံးကို အတည်ပြုရမည်။.

IEC စံနှုန်းများနှင့် စမ်းသပ်မှုလိုအပ်ချက်များ

ဗို့အားအဆင့်သတ်မှတ်ချက် သုံးခုသည် ထုတ်လုပ်သူ၏ ကျပန်းတောင်းဆိုချက်များမဟုတ်ပါ—၎င်းတို့ကို စမ်းသပ်မှုလုပ်ထုံးလုပ်နည်းများ၊ အနည်းဆုံးစွမ်းဆောင်ရည်စံနှုန်းများနှင့် မှတ်တမ်းတင်ခြင်းဆိုင်ရာ လိုအပ်ချက်များကို သတ်မှတ်သည့် တင်းကျပ်သော IEC နိုင်ငံတကာစံနှုန်းများက အုပ်ချုပ်သည်။.

IEC 60947 စီးရီး- ဗို့အားနိမ့်သော ခလုတ်ဂီယာနှင့် ထိန်းချုပ်ဂီယာ

IEC 60947 စီးရီးသည် ဗို့အားအဆင့်သတ်မှတ်ချက် အဓိပ္ပါယ်ဖွင့်ဆိုချက်များအတွက် အခြေခံအုတ်မြစ်ကို ပံ့ပိုးပေးသည် MCCBs, contactors များ, relay များ, ၊ မော်တာစတင်စက်များနှင့် ထိန်းချုပ်ကိရိယာများ-

  • IEC 60947-1: General rules establishing Ue, Ui, Uimp definitions, insulation coordination requirements, and test procedures applicable to all low-voltage switchgear
  • IEC ၆၀၉၄၇-၂: Specific requirements for circuit-breakers (MCCBs, ACBs), including short-circuit breaking capacity, selectivity categories, and voltage rating application
  • IEC 60947-4-1: Contactors and motor starters, defining utilization categories (AC-3, AC-4, etc.) and how Ue relates to motor switching capability
  • IEC 60947-5-1: Control circuit devices and switching elements (limit switches, selector switches, push-buttons)

All parts reference IEC 60947-1 for fundamental voltage rating definitions, then add product-specific test details.

IEC 60947-7-1: Terminal Blocks for Copper Conductors

Terminal blocks follow related standards:

  • IEC ၆၀၉၄၇-၇-၁: Defines temperature rise, dielectric withstand (validating Ui), short-time current withstand, and impulse tests (validating Uimp) for terminal blocks
  • Testing includes: Power-frequency dielectric test (60 seconds at test voltage derived from Ui) and impulse voltage test (1.2/50 μs waveform at rated Uimp)

Terminal blocks use the same fundamental Ui and Uimp framework as MCCBs and contactors, ensuring insulation coordination consistency across all panel components.

IEC 60664-1: Insulation Coordination Within Low-Voltage Systems

IEC 60664-1 provides the engineering tables that connect system voltage to required Uimp and clearances:

  • Overvoltage categories (I through IV) classify installation exposure to transients
  • Pollution degrees (1 through 4) classify environmental contamination levels
  • Rated impulse voltage tables: Map nominal system voltage and overvoltage category to minimum required Uimp
  • Clearance and creepage tables: Specify minimum air and surface distances based on Ui, pollution degree, and insulating material group

Engineers use IEC 60664-1 to determine what Uimp and clearances their application demands, then select equipment with datasheets showing adequate ratings.

IEC 61810-1: Electromechanical Relays

Electromechanical relays follow their own standard but use identical voltage rating concepts:

  • IEC 61810-1: Defines Ue (switching voltage), Ui (insulation voltage), and Uimp (impulse withstand voltage) for relay contacts and coils
  • Test procedures: Power-frequency dielectric tests and impulse tests mirror IEC 60947-1 methodology

A relay rated Ue 400V, Ui 690V, Uimp 6 kV uses the same interpretive framework as an MCCB with those ratings—only the product type differs.

Type Testing vs. Routine Testing

Voltage rating validation involves two test levels:

အမျိုးအစားစမ်းသပ်ခြင်း။ (performed once per design):

  • Comprehensive validation including dielectric withstand, impulse tests, temperature rise, endurance cycles
  • Conducted on representative samples in accredited test laboratories
  • Results documented in type test reports and published on datasheets
  • Expensive, time-consuming—manufacturers don’t repeat for every production unit

ပုံမှန်စစ်ဆေးမှု (performed on every unit or production batch):

  • Basic verification: visual inspection, dimensional checks, simplified dielectric test (lower voltage, shorter duration)
  • Ensures manufacturing consistency without repeating full type test battery
  • Quick, cost-effective quality control

When you read a datasheet showing Ue, Ui, and Uimp, those values represent type-tested, certified performance. Routine testing confirms each production unit meets the type-tested design.

Practical Selection Guide: Using Voltage Ratings Correctly

Selecting equipment with appropriate voltage ratings requires a systematic approach. Follow this decision framework to match ratings to your installation requirements.

Step 1: Identify Your System Nominal Voltage

Start with basic system facts:

  • Single-phase systems: 120V, 230V, 240V AC
  • Three-phase systems: 208V, 380V, 400V, 415V, 480V, 600V, 690V AC
  • DC systems: 24V, 48V, 110V, 220V DC (common in control/battery applications)

ဒါက သင့်ရဲ့ minimum Ue requirement. Equipment rated Ue lower than your system voltage cannot be used; equipment rated Ue equal to or higher than system voltage is acceptable from an operational voltage standpoint.

Step 2: Determine Installation Overvoltage Category

Consult IEC 60664-1 or local electrical codes to classify your installation:

အမျိုးအစား I: Sensitive electronic equipment with local surge protection (rare in industrial applications)

အမျိုးအစား II: Appliance and socket-outlet circuits, portable equipment at least 10 meters from Category III sources (residential, light commercial)

အမျိုးအစား III: Fixed equipment in buildings, distribution panels, industrial machinery (most common industrial application)

အမျိုးအစား IV: Origin of installation, service entrance equipment, utility meters, overhead lines

Your installation category determines the minimum required Uimp. For a 400V system:

  • Category II → Uimp ≥ 2.5 kV
  • Category III → Uimp ≥ 6 kV (often specified as 8 kV for better margin)
  • အမျိုးအစား IV → Uimp ≥ 8 kV

အဆင့် ၃: ပတ်ဝန်းကျင် ညစ်ညမ်းမှု အတိုင်းအတာကို ဆန်းစစ်ပါ။

IEC 60664-1 အရ ညစ်ညမ်းမှု အဆင့်များကို အကဲဖြတ်ပါ:

  • ညစ်ညမ်းမှု ဒီဂရီ ၁: သန့်ရှင်းသော ပတ်ဝန်းကျင်များ၊ လုံလုံခြုံခြုံ ပိတ်ထားသော အရာများ (ရှားပါးသည်)
  • ညစ်ညမ်းမှု ဒီဂရီ ၂: ပုံမှန် အိမ်တွင်း အခြေအနေများ၊ လျှပ်ကူး မညစ်ညမ်းသော အရာများသာ (ထိန်းချုပ်ရေး အကန့်အများစု)
  • ညစ်ညမ်းမှု ဒီဂရီ ၃: လျှပ်ကူး ညစ်ညမ်းသော အရာများ သို့မဟုတ် ခြောက်သွေ့သော လျှပ်မကူးသော ညစ်ညမ်းသော အရာများ စိုစွတ်သောအခါ လျှပ်ကူးနိုင်သော အရာများ (စက်မှု ပတ်ဝန်းကျင်များ၊ အပြင်ဘက် တပ်ဆင်ခြင်းများ)
  • ညစ်ညမ်းမှု ဒီဂရီ ၄: မိုး၊ နှင်း သို့မဟုတ် ပြင်းထန်သော ညစ်ညမ်းမှုကြောင့် အမြဲတစေ လျှပ်ကူး ညစ်ညမ်းသော အရာများ

ညစ်ညမ်းမှု အဆင့် မြင့်လေလေ ပိုကြီးသော Creepage Distance ရှိသော စက်ပစ္စည်းများ လိုအပ်လေလေ ဖြစ်ပြီး၊ ဆိုလိုသည်မှာ တူညီသော Clearance Capability အတွက် Ui Rating များ မြင့်မားလေလေ ဖြစ်သည်။ ညစ်ညမ်းမှု အဆင့် ၃ ရှိ 400V စနစ်သည် အဆင့် ၂ တွင် တူညီသော ဗို့အားထက် Creepage ပိုကြီးရန် လိုအပ်သည်။.

အဆင့် ၄: လုံလောက်သော Margin ဖြင့် Equipment Ui ကို ရွေးချယ်ပါ။

အထွေထွေ စည်းမျဉ်း: သင်၏ စနစ် Nominal Voltage ၏ အနည်းဆုံး 1.5 ဆရှိသော Ui ဖြင့် စက်ပစ္စည်းကို သတ်မှတ်ပါ၊ ပိုမြင့်လေ ပိုကောင်းလေ ဖြစ်သည်။.

အသုံးများသော စနစ်များအတွက်:

  • 400V သုံးဆင့် စနစ်: Ui ≥ 690V (1.73× Margin) ကို သတ်မှတ်ပါ
  • 480V သုံးဆင့် စနစ်: Ui ≥ 690V သို့မဟုတ် 800V ကို သတ်မှတ်ပါ
  • 230V တစ်ဆင့် စနစ်: Ui ≥ 400V သို့မဟုတ် 500V ကို သတ်မှတ်ပါ

ဤ Margin သည် ဗို့အား အပြောင်းအလဲများ၊ ယာယီ Overvoltage များ နှင့် စက်ပစ္စည်း ဝန်ဆောင်မှု သက်တမ်းတစ်လျှောက် လျှပ်ကာ အိုမင်းခြင်းတို့ကို ထည့်သွင်းတွက်ချက်ထားသည်။.

အဆင့် ၅: Uimp သည် တပ်ဆင်ခြင်း အမျိုးအစားနှင့် ကိုက်ညီမှု ရှိမရှိ စစ်ဆေးပါ။

အဆင့် ၂ မှ သင်၏ တပ်ဆင်ခြင်း အမျိုးအစားနှင့် ဆန့်ကျင်၍ စက်ပစ္စည်း Datasheet များကို Cross-Check လုပ်ပါ:

  • သင်၏ စနစ် ဗို့အားနှင့် အမျိုးအစားအတွက် IEC 60664-1 အနည်းဆုံးထက် ကြေငြာထားသော Uimp ≥ ရှိရန် သေချာပါစေ။
  • စက်မှုဆိုင်ရာ အမြဲတပ်ဆင်ခြင်းများ (အမျိုးအစား III) သည် ပုံမှန်အားဖြင့် Uimp 6-8 kV အနည်းဆုံး လိုအပ်သည်။
  • ကုန်ကျစရိတ် သက်သာစေရန်အတွက် အောက်တွင် မသတ်မှတ်ပါနှင့်—Surge Failure များသည် ခန့်မှန်းရခက်ပြီး ကုန်ကျစရိတ် ကြီးမြင့်သည်။

အဆင့် ၆: ရွေးချယ်ထားသော Ue တွင် Current Rating များကို အတည်ပြုပါ။

စက်ပစ္စည်း Current Rating များ (Ie, In) ကို သီးခြား Ue တန်ဖိုးများတွင် ကြေငြာထားသည်။ အောက်ပါတို့ကို အတည်ပြုပါ:

  • Current Rating သည် သင်၏ Load အတွက် လုံလောက်မှု ရှိမရှိ ကြေငြာထားသော Ue တွင်
  • စက်ပစ္စည်းသည် Ue Option များစွာကို ဖော်ပြပါက သင်ရွေးချယ်ထားသော ဗို့အားတွင် Current Derate မဖြစ်ကြောင်း စစ်ဆေးပါ။
  • Contactor များသည် အထူးသဖြင့် မြင့်မားသော Ue အဆင့်များတွင် လျော့နည်းသွားသော Ie ကို ပြသသည်—Current သည် အမြဲတမ်း တည်ငြိမ်နေသည်ဟု မယူဆပါနှင့်။

အဆင့် ၇: လိုက်နာမှု အတည်ပြုခြင်းအတွက် ရွေးချယ်မှုများကို မှတ်တမ်းတင်ပါ။

အောက်ပါတို့ကို ပြသသော သတ်မှတ်ချက် မှတ်တမ်းကို ထိန်းသိမ်းပါ:

  • စနစ် Nominal Voltage နှင့် တပ်ဆင်ခြင်း အမျိုးအစား
  • ရွေးချယ်ထားသော စက်ပစ္စည်း Ue, Ui, Uimp တန်ဖိုးများ
  • ညစ်ညမ်းမှု အဆင့်နှင့် လိုအပ်သော Creepage Distance များ
  • စံနှုန်း လုပ်ထုံးလုပ်နည်းမှ သွေဖည်မှုများအတွက် ရှင်းလင်းချက်

ဤမှတ်တမ်းသည် အတည်ပြုခြင်း လုပ်ငန်းစဉ်များ၊ စစ်ဆေးခြင်း ပြန်လည်သုံးသပ်ခြင်းများနှင့် အနာဂတ် ပြုပြင်ထိန်းသိမ်းခြင်း/အစားထိုးခြင်း ဆုံးဖြတ်ချက်များကို အထောက်အပံ့ပေးသည်။.

ဆုံးဖြတ်ချက် Flowchart အကျဉ်းချုပ်

  1. စနစ်ဗို့အား → အနည်းဆုံး Ue ကို သတ်မှတ်သည်
  2. တပ်ဆင်ခြင်း အမျိုးအစား (IEC 60664-1) → အနည်းဆုံး Uimp ကို သတ်မှတ်သည်
  3. လေထုညစ်ညမ်းမှုဒီဂရီ + ဓာတ်အား → လိုအပ်သော Creepage ကို သတ်မှတ်သည် (Ui ရွေးချယ်မှုကို အတည်ပြုသည်)
  4. Load လက္ခဏာများ + Ue → လိုအပ်သော Ie နှင့် အသုံးပြုမှု အမျိုးအစားကို သတ်မှတ်သည်
  5. Rating အားလုံးကို Cross-Check လုပ်ပါ → Ue ≤ Ui, Uimp လုံလောက်မှု ရှိမရှိ၊ Current လုံလောက်မှု ရှိမရှိ သေချာစေသည်

Rating တစ်ခုခုသည် အနည်းအကျဉ်း သို့မဟုတ် မရှင်းလင်းပါက နောက်ထပ် မြင့်မားသော စံနှုန်း Rating ကို သတ်မှတ်ပါ။ ကုန်ကျစရိတ် ကွာခြားမှုသည် Field Failure များနှင့် အရေးပေါ် အစားထိုးမှုများနှင့် နှိုင်းယှဉ်ပါက အနည်းငယ်သာ ရှိသည်။.

ဗို့အားအဆင့်သတ်မှတ်ချက်များအတွက် စက်ပစ္စည်းရွေးချယ်မှု ဆုံးဖြတ်ချက်မူဘောင် စီးဆင်းမှုဇယား
ပုံ ၅: စက်ပစ္စည်း ဗို့အား Rating သတ်မှတ်ချက်အတွက် စနစ်တကျ ချဉ်းကပ်နည်း။ ဤ ဆုံးဖြတ်ချက် မူဘောင်သည် အင်ဂျင်နီယာများကို Ue ကို စနစ် ဗို့အားနှင့် ကိုက်ညီစေခြင်း၊ လျှပ်ကာ Margin အတွက် Ui ကို အတည်ပြုခြင်း၊ တပ်ဆင်ခြင်း အမျိုးအစားနှင့် ဆန့်ကျင်၍ Uimp ကို စစ်ဆေးခြင်းနှင့် Current Rating များကို အတည်ပြုခြင်း အပါအဝင် ပြီးပြည့်စုံသော ရွေးချယ်ခြင်း လုပ်ငန်းစဉ်ကို လမ်းညွှန်ပေးသည်- ဤဖွဲ့စည်းပုံ ချဉ်းကပ်နည်းကို လိုက်နာခြင်းသည် ဗို့အား Parameter အားလုံးကို စနစ်တကျ သတ်မှတ်ထားကြောင်း သေချာစေသည်။.

ရှောင်ရန်အဖြစ်များသော Specification အမှားများ

အတွေ့အကြုံရှိသော အင်ဂျင်နီယာများသည်ပင် အချိန်ဖိအားအောက်တွင် အလုပ်လုပ်သောအခါ သို့မဟုတ် မရင်းနှီးသော စက်ပစ္စည်း အမျိုးအစားများနှင့် ဆက်ဆံသောအခါ ဗို့အား Rating အမှားများ ပြုလုပ်တတ်ကြသည်။ ဤတွင် အဖြစ်အများဆုံး အမှားများနှင့် ၎င်းတို့ကို ရှောင်ရှားနည်းများ ဖြစ်သည်။.

အမှား ၁: Ue ကိုသာ အသုံးပြုပြီး Ui/Uimp ကို လျစ်လျူရှုခြင်း

အမှား: Ui နှင့် Uimp ကို မစစ်ဆေးဘဲ စနစ် ဗို့အားနှင့် ကိုက်ညီသော Ue ပေါ်တွင်သာ အခြေခံ၍ စက်ပစ္စည်းကို သတ်မှတ်ခြင်း။.

အဘယ်ကြောင့် မှားသနည်း: Ue သည် လည်ပတ်မှု လိုက်ဖက်ညီမှုကို အတည်ပြုသော်လည်း လျှပ်ကာ အားကောင်းမှု သို့မဟုတ် Surge ခံနိုင်ရည်နှင့် ပတ်သက်၍ ဘာမျှ မပြောပါ။ မှန်ကန်သော Ue ရှိသော်လည်း Uimp မလုံလောက်သော စက်ပစ္စည်းသည် ယာယီ ဖြစ်ရပ်များပြီးနောက် ခန့်မှန်းရခက်စွာ ပျက်ကွက်သည်။.

မှန်ကန်သော ချဉ်းကပ်နည်း: Rating သုံးခုစလုံးကို အမြဲတမ်း အတည်ပြုပါ။ 400V စနစ်အတွက် Ue ≥ 400V ရှိမရှိ စစ်ဆေးပါ။ နှင့် Ui ≥ 690V နှင့် Uimp ≥ 6-8 kV (တပ်ဆင်ခြင်း အမျိုးအစားပေါ် မူတည်သည်)။.

အမှား ၂: Ui ကို အမြင့်ဆုံး လည်ပတ် ဗို့အားအဖြစ် သဘောထားခြင်း

အမှား: Ui 690V အဆင့်သတ်မှတ်ထားသော စက်ပစ္စည်းသည် 690V တွင် အဆက်မပြတ် လည်ပတ်နိုင်သည်ဟု ယူဆခြင်း။.

အဘယ်ကြောင့် မှားသနည်း: Ui သည် လည်ပတ်မှု ကန့်သတ်ချက်မဟုတ်ဘဲ လျှပ်ကာ ရည်ညွှန်း ဗို့အားဖြစ်သည်။ အခြေခံ စည်းမျဉ်းမှာ Ue ≤ Ui ဖြစ်သည်—လည်ပတ် ဗို့အားသည် Ui တန်ဖိုး မည်သို့ပင်ရှိစေကာမူ ကြေငြာထားသော Ue ထက် မကျော်လွန်ရပါ။.

မှန်ကန်သော ချဉ်းကပ်နည်း: စနစ် ဗို့အားကို Ui နှင့် မဟုတ်ဘဲ Ue နှင့် ကိုက်ညီအောင် လုပ်ပါ။ 690V စနစ်အတွက် Ui 800V သို့မဟုတ် 1000V ရှိသော Ue 690V (သို့မဟုတ် ပိုမြင့်သော) အဆင့်သတ်မှတ်ထားသော စက်ပစ္စည်းကို ရွေးချယ်ပါ။ ၎င်း၏ Ui သည် 690V ဖြစ်သောကြောင့် Ue 400V အဆင့်သတ်မှတ်ထားသော စက်ပစ္စည်းကို မသုံးပါနှင့်။.

အမှား ၃: Uimp ကို ရွေးချယ်သောအခါ တပ်ဆင်ခြင်း အမျိုးအစားကို လျစ်လျူရှုခြင်း

အမှား: စက်မှုဆိုင်ရာ အမြဲတပ်ဆင်ခြင်းများ (အမျိုးအစား III) အတွက် လူနေအိမ်အဆင့် စက်ပစ္စည်း (Uimp 4-6 kV) ကို သတ်မှတ်ခြင်း။.

အဘယ်ကြောင့် မှားသနည်း: IEC 60664-1 သည် လျှပ်စစ်ဓာတ်အား ထောက်ပံ့မှု အရင်းအမြစ်နှင့် ပိုမိုနီးကပ်သော တပ်ဆင်ခြင်းများအတွက် Uimp ပိုမိုမြင့်မားရန် လိုအပ်သည်။ အမျိုးအစား III စက်မှု ပတ်ဝန်းကျင်များသည် အမျိုးအစား II အသုံးအဆောင် ဆားကစ်များထက် ပိုမိုပြင်းထန်သော ယာယီ ဖြစ်ရပ်များကို ရင်ဆိုင်ရသည်။ Uimp မလုံလောက်သော စက်ပစ္စည်းသည် စုပုံသော လျှပ်ကာ ယိုယွင်းပျက်စီးခြင်းနှင့် မမျှော်လင့်သော ပျက်ကွက်မှုများကို ခံစားရသည်။.

မှန်ကန်သော ချဉ်းကပ်နည်း: တပ်ဆင်ခြင်း အမျိုးအစားကို ဦးစွာ ဆုံးဖြတ်ပါ၊ ထို့နောက် သင့်လျော်သော Uimp ရှိသော စက်ပစ္စည်းကို ရွေးချယ်ပါ။ စက်မှုဆိုင်ရာ အသုံးချမှု အများစု (အမျိုးအစား III) အတွက် Uimp ≥ 8 kV ကို သတ်မှတ်ပါ။ ဝန်ဆောင်မှု ဝင်ပေါက် စက်ပစ္စည်း (အမျိုးအစား IV) အတွက် Uimp ≥ 12 kV ကို အသုံးပြုပါ။.

အမှား ၄: ယိုစိမ့်မှုအပေါ် ညစ်ညမ်းမှုဒီဂရီ၏ သက်ရောက်မှုကို လျစ်လျူရှုခြင်း

အမှား: ပတ်ဝန်းကျင် ညစ်ညမ်းမှုကို ထည့်မတွက်ဘဲ ဗို့အားအဆင့်သတ်မှတ်ချက်များအပေါ် မူတည်၍ စက်ပစ္စည်းကို ရွေးချယ်ခြင်း။.

အဘယ်ကြောင့် မှားသနည်း: ညစ်ညမ်းမှုဒီဂရီ မြင့်လေလေ လျှပ်ကူးပစ္စည်းများကြား ယိုစိမ့်မှုအကွာအဝေး ပိုလိုအပ်လေဖြစ်သည်။ ညစ်ညမ်းမှုဒီဂရီ ၂ (သန့်ရှင်းသော ထိန်းချုပ်မှုအကန့်) အတွက် သင့်လျော်သော စက်ပစ္စည်းသည် ဒီဂရီ ၃ (ဖုန်/အစိုဓာတ်ပါသော စက်မှုပတ်ဝန်းကျင်) အတွက် ယိုစိမ့်မှု မလုံလောက်ပါ။ ၎င်းသည် ခြေရာခံခြင်းနှင့် လျှပ်စီးကြောင်းပျက်စီးခြင်းကို ဖြစ်စေသည်။.

မှန်ကန်သော ချဉ်းကပ်နည်း: ပတ်ဝန်းကျင်ကို ရိုးရိုးသားသား အကဲဖြတ်ပါ (စက်မှုလုပ်ငန်းအများစုသည် ဒီဂရီ ၃ ဖြစ်ပြီး ဒီဂရီ ၂ မဟုတ်ပါ)၊ ထို့နောက် သင့်ညစ်ညမ်းမှုဒီဂရီအတွက် လုံလောက်သော Ui နှင့် အတည်ပြုထားသော ယိုစိမ့်မှုအကွာအဝေးရှိသော စက်ပစ္စည်းကို ရွေးချယ်ပါ။ သံသယရှိလျှင် လုံလောက်သောအကွာအဝေးကိုသေချာစေရန် နောက်ထပ်မြင့်မားသော Ui အဆင့်သတ်မှတ်ချက်ကို သတ်မှတ်ပါ။.

အမှား ၅: လက်ရှိအဆင့်သတ်မှတ်ချက်များသည် ဗို့အားနှင့်မသက်ဆိုင်ဟု ယူဆခြင်း

အမှား: Ue 400V တွင် Ie 95A အဆင့်သတ်မှတ်ထားသော contactor ကို ရွေးချယ်ပြီး Ue 690V တွင် တူညီသော 95A စွမ်းရည်ကို မျှော်လင့်ခြင်း။.

အဘယ်ကြောင့် မှားသနည်း: ဗို့အားမြင့်လေလေ contact arc ၏ အနှောင့်အယှက်ကို ပိုမိုပြင်းထန်စေသည်။ Contactors နှင့် switches များသည် ဗို့အားမြင့်လေလေ လက်ရှိစွမ်းရည်ကို လျှော့ချပြလေ့ရှိသည်။ Datasheets များသည် Ue/Ie ပေါင်းစပ်မှုများစွာကို ဖော်ပြသည်—Ue တိုးလာသည်နှင့်အမျှ Ie တန်ဖိုးသည် လျော့နည်းသွားသည်။.

မှန်ကန်သော ချဉ်းကပ်နည်း: သင့်လည်ပတ်ဗို့အားတွင် လက်ရှိအဆင့်သတ်မှတ်ချက်များကို အမြဲဖတ်ပါ။ သင်သည် 690V လည်ပတ်မှုအတွက် ဒီဇိုင်းဆွဲနေပါက Ue 690V တွင် ကြေငြာထားသော Ie တန်ဖိုးကို အသုံးပြုပါ၊ Ue 400V တွင် ကြေငြာထားသော (ပိုမိုမြင့်မားသော) တန်ဖိုးကို မသုံးပါနှင့်။.

အမှား ၆: လူနေအိမ်နှင့် စက်မှုသုံးပစ္စည်းများ ရောနှောခြင်း

အမှား: ကုန်ကျစရိတ်သက်သာစေရန် စက်မှုထိန်းချုပ်မှုအကန့်များတွင် လူနေအိမ် MCCB များ (Uimp 6 kV အဆင့်သတ်မှတ်ထားသည်) ကို သတ်မှတ်ခြင်း။.

အဘယ်ကြောင့် မှားသနည်း: လူနေအိမ်သုံးပစ္စည်းများကို ယာယီထိတွေ့မှုနည်းသော Category II အသုံးချပရိုဂရမ်များအတွက် စမ်းသပ်ပြီး အသိအမှတ်ပြုထားသည်။ စက်မှုပတ်ဝန်းကျင်များ (Category III/IV) သည် လူနေအိမ်သုံးပစ္စည်း၏ ဒီဇိုင်းအပေါ်ယံလွှာထက် ကျော်လွန်သည်။ လူနေအိမ်နှင့် စက်မှုအစိတ်အပိုင်းများကို ရောနှောခြင်းသည် ညှိနှိုင်းမှုကွာဟချက်များနှင့် လိုက်နာမှုဆိုင်ရာပြဿနာများကို ဖန်တီးပေးသည်။.

မှန်ကန်သော ချဉ်းကပ်နည်း: စက်ပစ္စည်းအဆင့်ကို တပ်ဆင်မှုအမျိုးအစားနှင့် ကိုက်ညီအောင်ထားပါ။ စက်ရုံ၊ အပင်နှင့် အဆောက်အဦတပ်ဆင်မှုများအတွက် စက်မှုအဆင့်သတ်မှတ်ထားသော အစိတ်အပိုင်းများ (အနည်းဆုံး Uimp 8 kV) ကို အသုံးပြုပါ။ လူနေအိမ်အဆင့်ပစ္စည်းများ (Uimp 4-6 kV) ကို အမှန်တကယ် လူနေအိမ်အသုံးချပရိုဂရမ်များအတွက် သီးသန့်ထားပါ။.

အမှား ၇: အစားထိုးပစ္စည်း အဆင့်သတ်မှတ်ချက်များကို အတည်ပြုရန် မေ့လျော့ခြင်း

အမှား: လက်ရှိအဆင့်သတ်မှတ်ချက်များနှင့် ကိုက်ညီသော်လည်း ဗို့အားအဆင့်သတ်မှတ်ချက်များ နိမ့်သော “ညီမျှသော” ကိရိယာများဖြင့် ပျက်ကွက်သောကိရိယာကို အစားထိုးခြင်း။.

အဘယ်ကြောင့် မှားသနည်း: မူရင်းကိရိယာကို အကြောင်းပြချက်တစ်ခုအတွက် ဗို့အားအဆင့်သတ်မှတ်ချက်များ (Ue, Ui, Uimp) အပြည့်အစုံဖြင့် သတ်မှတ်ထားသည်။ မလုံလောက်သော Ui သို့မဟုတ် Uimp ပါသော အစားထိုးကိရိယာများသည် ရုပ်ပိုင်းဆိုင်ရာအရ ကိုက်ညီပြီး အစပိုင်းတွင် အလုပ်လုပ်နိုင်သော်လည်း လျှပ်စစ်ဖိအားအောက်တွင် စောစီးစွာ ပျက်ကွက်နိုင်သည်။.

မှန်ကန်သော ချဉ်းကပ်နည်း: ဗို့အားအဆင့်သတ်မှတ်ချက်များအားလုံးအပါအဝင် မူရင်းကိရိယာ၏ သတ်မှတ်ချက်များကို မှတ်တမ်းတင်ပါ။ အစားထိုးပစ္စည်းများသည် လက်ရှိစွမ်းရည်နှင့် ရုပ်ပိုင်းဆိုင်ရာခြေရာကိုသာမက အဆင့်သတ်မှတ်ချက်သုံးခုစလုံး (Ue, Ui, Uimp) နှင့် ကိုက်ညီကြောင်း သို့မဟုတ် ကျော်လွန်ကြောင်း အတည်ပြုပါ။.

နိဂုံး

Ue, Ui နှင့် Uimp တို့သည် တူညီသောအရာကို ပြောရန် နည်းလမ်းသုံးမျိုးမဟုတ်ပါ။ ၎င်းတို့သည် မတူညီသော လျှပ်စစ်ဖိအားများကို ဖြေရှင်းပေးသည့် မတူညီသော တိုင်းတာမှုသုံးခုဖြစ်သည်- လည်ပတ်နိုင်စွမ်း (Ue)၊ လျှပ်ကာအစွမ်းသတ္တိ (Ui) နှင့် ယာယီလှိုင်းခုခံနိုင်စွမ်း (Uimp)။ စက်ပစ္စည်းရွေးချယ်မှုသည် သင့်စနစ်ဗို့အား၊ တပ်ဆင်မှုအမျိုးအစားနှင့် ပတ်ဝန်းကျင်အခြေအနေများနှင့် နှိုင်းယှဉ်၍ သုံးခုစလုံးကို အကဲဖြတ်ရန် လိုအပ်သည်။.

မေးခွန်းဖွင့်ပွဲ—MCCB တစ်ခုသည် “Ue 400V, Ui 690V, Uimp 8kV” နှင့် အခြားတစ်ခုသည် “Ue 690V, Ui 800V, Uimp 6kV” ကိုပြသသောအခါ 400V စနစ်နှင့် မည်သည့် MCCB ကိုက်ညီသနည်း—ယခုတွင် ရှင်းလင်းသောအဖြေရှိသည်။ ပထမ MCCB သည် သင့်လည်ပတ်ဗို့အား (Ue 400V) နှင့် သင့်လျော်သော လျှပ်ကာအနားသတ် (Ui 690V) နှင့် စက်မှုအဆင့် လှိုင်းခုခံနိုင်စွမ်း (Uimp 8 kV) တို့နှင့် ကိုက်ညီပြီး Category III တပ်ဆင်မှုများအတွက် သင့်လျော်ပါသည်။ ဒုတိယတစ်ခုသည် လည်ပတ်ဗို့အားအတွက် အလွန်အကျွံသတ်မှတ်ထားသည် (Ue 690V သည် သင့် 400V လိုအပ်ချက်ထက် ကျော်လွန်သည်) နှင့် လှိုင်းကာကွယ်မှုအတွက် အလွန်အကျွံသတ်မှတ်ထားသည် (Uimp 6 kV သည် စက်မှု Category III အတွက် အနည်းငယ်သာရှိသည်)။ ပထမကိရိယာသည် မှန်ကန်သောရွေးချယ်မှုဖြစ်သည်။.

သင့်လျော်သော သတ်မှတ်ချက်ဆိုသည်မှာ စနစ်တကျ အကဲဖြတ်ခြင်းကို ဆိုလိုသည်- အနည်းဆုံး Ue ကို ဆုံးဖြတ်ရန် စနစ်ဗို့အားကို ခွဲခြားသတ်မှတ်ပါ၊ လိုအပ်သော Uimp ကို သတ်မှတ်ရန် တပ်ဆင်မှုအမျိုးအစားကို ခွဲခြားပါ၊ Ui နှင့် ယိုစိမ့်မှု လုံလောက်မှုကို အတည်ပြုရန် ညစ်ညမ်းမှုဒီဂရီကို အကဲဖြတ်ပြီး သင့်လည်ပတ်ဗို့အားတွင် လက်ရှိအဆင့်သတ်မှတ်ချက်များကို ဖြတ်ကျော်စစ်ဆေးပါ။ အဆင့်သတ်မှတ်ချက်များ အနည်းငယ်သာရှိပါက နောက်ထပ်မြင့်မားသော စံတန်ဖိုးကို သတ်မှတ်ပါ—ဗို့အားအဆင့်သတ်မှတ်ချက်များကို အလွန်အကျွံအင်ဂျင်နီယာလုပ်ခြင်းသည် စောစီးစွာ ပျက်ကွက်ခြင်းနှင့် အရေးပေါ်အစားထိုးခြင်းထက် များစွာသက်သာသည်။.

အရေးကြီးဆုံးကတော့ သင့်ရွေးချယ်မှုတွေကို မှတ်တမ်းတင်ပါ။ Ue, Ui နှင့် Uimp ကိုပြသသည့် စက်ပစ္စည်းဒေတာစာရွက်များသည် စမ်းသပ်ပြီး အသိအမှတ်ပြုထားသော စွမ်းဆောင်ရည်ကို ကိုယ်စားပြုသည်။ ထိုနံပါတ်သုံးလုံးသည် စက်ပစ္စည်းတစ်ခုသည် သင့်အသုံးချပရိုဂရမ်၏ လျှပ်စစ်ဖိအားပရိုဖိုင်အပြည့်အစုံကို ကိုင်တွယ်နိုင်ခြင်းရှိမရှိကို ပြောပြသည်—ယနေ့၏ တည်ငြိမ်သောလည်ပတ်မှုသာမက ဗို့အားအတက်အကျများ၊ ပတ်ဝန်းကျင်ညစ်ညမ်းမှုနှင့် ယာယီလှိုင်းများပါဝင်သည့် နှစ်များစွာကိုပါ ကိုင်တွယ်နိုင်ခြင်းရှိမရှိကို ပြောပြသည်။ ၎င်းတို့ကို မှန်ကန်စွာဖတ်ပါ၊ ဂရုတစိုက်သတ်မှတ်ပါ၊ သင့်လျှပ်စစ်စနစ်များသည် ထိုစံနှုန်းများကတိပေးထားသည့် ယုံကြည်စိတ်ချရသော စွမ်းဆောင်ရည်ကို ပေးဆောင်လိမ့်မည်။.

စာရေးဆရာပုံ

ကြ်န္ေတာ္ကေတာ့ဂျိုး၊အနုအတူပရော်ဖက်ရှင်နယ် ၁၂ နှစ်အတွေ့အကြုံအတွက်လျှပ်စစ်လုပ်ငန်း။ မှာ VIOX လျှပ်စစ်၊ငါ့အာရုံစူးစိုက်အပေါ်ဖြစ်ပါသည်ပို့အရည်အသွေးမြင့်လျှပ်စစ်ဖြေရှင်းနည်းများဖြည့်ဆည်းဖို့အံဝင်ခွင်လိုအပ်ချက်များကိုကျွန်ုပ်တို့၏ဖောက်သည်များ၏။ ငါ့ကျွမ်းကျင်မှုကိုအထိစက္မႈအလျောက်၊လူနေသောဝါယာကြိုး၊နှင့်မပွားဖြစ်လျှပ်စစ်စနစ်များ။အကြှနျုပျကိုဆက်သွယ်ရန် [email protected] ဦးရှိသည်မည်သည့်မေးခွန်းများကို။