ခြုံငုံသုံးသပ်ချက်
VIOX KCQ7 electromagnetic motor starters combine an AC contactor,
thermal overload relay and start/stop push buttons in an enclosure. They
are designed for direct starting and stopping of three-phase
squirrel-cage induction motors, with AC-3 frame currents from 9 to 93 A
and rated operating voltages up to 660 V.
အင်္ဂါရပ်များ
- Enclosed contactor and thermal overload relay assembly.
- Green start and red stop push buttons.
- CJX2-D or CJX2s contactor options with matching overload
relays. - Adjustable overload protection selected to suit the motor
ကျွန်တော်တို့ ‘ကျွေး’ ဖို့ စတင်လိုက်တယ်။ 500 Amps… 600 Amps… 800 Amps…. - Detachable cover for component inspection and maintenance.
နည်းပညာဆိုင်ရာသတ်မှတ်ချက်များ
| မော်ဒယ် | Frame current | AC-3 motor power at 220 V | At 380 V | At 660 V |
|---|---|---|---|---|
| KCQ7-09 | 9 A | 2.2 kW | 4 kW | 5.5 kW |
| KCQ7-12 | 12 A | 3 kW | 5.5 kW | 7.5 kW |
| KCQ7-18 | 18 A | 4 kW | 7.5 kW | 10 kW |
| KCQ7-25 | 25 A | 5.5 kW | 11 kW | 15 kW |
| KCQ7-32 | 32 A | 7.5 kW | 15 kW | 18.5 kW |
| KCQ7-40 | 40 A | 11 kW | 18.5 kW | 18.5 kW |
| KCQ7-50 | ၅၀ အမ်ပီယာ | 15 kW | 22 kW | 37 kW |
| KCQ7-65 | 65 A | 18.5 kW | 30 kW | 37 kW |
| KCQ7-80 | 80 A | 22 kW | 37 kW | 45 kW |
| KCQ7-93 | 93 A | 25 kW | 45 kW | 45 kW |
| ဇာတိ | အင္တာနက္စာမ်က္ႏွာ |
|---|---|
| လျှောက်လွှာ | Direct starting of three-phase squirrel-cage induction motors |
| အသုံးပြုမှု အမျိုးအစား | သတ္မွတ္အ-၃ |
| ပေးသွင်းမှု ကြိမ်နှုန်း | 50 Hz or 60 Hz |
| သတ်မှတ်ထားသော လုပ်ငန်းသုံးဗို့အား (Rated operating voltage) | Up to 660 V |
| AC coil voltage options | 36 V, 110 V, 220 V, 380 V |
| Coil pull-in range | 85%–110% Us |
| Coil release range | 20%–75% Us |
| Enclosure protection, KCQ7-09–32 | IP55 |
| Enclosure protection, KCQ7-40–93 | IP20, per detailed enclosure specification |
| ကိုးကားထားသော စံနှုန်းများ | IEC/EN 60947-4-1; GB/T 14048.4 |
| ပုံမှန် ပတ်ဝန်းကျင် အပူချိန် | −5°C to +40°C; 24-hour average ≤+35°C |
| Normal installation altitude | ≤2000 m |
ရွေးချယ်မှု
Select the frame by motor voltage and AC-3 duty, then select an
overload-relay setting range that includes the motor nameplate current.
Frame current is not the relay adjustment setting. The overload relay
does not replace coordinated short-circuit protection.
The larger KCQ7-40–93 enclosures must not be treated as IP55. Choose
the enclosure protection appropriate to the installation environment and
specify it in the quotation request.
အတိုင်းအတာ
The catalogue provides separate enclosure drawings for KCQ7-09–18,
KCQ7-25–32 and KCQ7-40–93. The reference sheet below includes dimensions
and the model/relay selection table.
မှာယူခြင်းဆိုင်ရာ အချက်အလက်
Provide the starter model, motor voltage, power and full-load
current, coil voltage and frequency, overload-relay setting range,
enclosure requirements and quantity.