VIOX HR17 690VAC 400A Horizontal 3P Fuse Switch Disconnector

HR17 400A 3P VIOX YR:HR17-690VAC 400A Horizontal 3P Fuse Switch Disconnector is suitable for short circuit protection and overload protection of cable and power equipment of the distribution system. In the case of a short circuit, the current can be broken by the fuse link inside.

Řada VIOX
HR17
Jmenovité napětí
690VAC
Jmenovitý proud
400A
Standardní
IEC 60269

Přehled

HR17 400A 3P VIOX YR:HR17-690VAC 400A Horizontal 3P Fuse Switch Disconnector is suitable for short circuit protection and overload protection of cable and power equipment of the distribution system. In the case of a short circuit, the current can be broken by the fuse link inside. With the features of high isolating function and high durability, YR:HR17-400/3 Horizontal Fuse switch disconnector can withstand high short circuits.

690VAC 400A Horizontal 3P Fuse Switch Disconnector

Funkce

  • IEC60947-3
  • Rated voltage 690VAC and current capacity 400A for hrc fuse switch disconnector applications.
  • High interrupting performance (High Breaking Capacity) with rapid current-limiting fault clearing.
  • Engineered and tested in accordance with IEC 60269 standards.
  • Precision-engineered low-power-loss silver-plated contacts and high-temperature ceramic or flame-retardant housing.
  • Direct OEM replacement geometry for standardized industrial, solar PV, ESS, and EV protection panels.

Specifikace

HR17 Technical Specifications

Model / Size Jmenovité napětí (V) Jmenovitý proud (A) Power Frequency Withstand Voltage (V) Recommended Fuse Link Model/Size Celkový rozměr
A E H H1 B
YR:HR17-400/3 690V 400A 3000V NT2,NH2 288 210 126 335 130

Selection & Installation Notes

  • Verify system maximum voltage (690VAC) and prospective short-circuit fault current before selecting the fuse link or holder rating.
  • Apply ambient-temperature derating when operating inside sealed outdoor combiner boxes or high-density inverter cabinets above 40°C.
  • Always de-energize circuits before replacing cylindrical, blade, or bolted fuse links, and use insulated fuse pullers for NH/NT types.
  • Explore the complete VIOX Fuse & Fuse Holder catalog for matched holders, bases, and disconnectors.

ČASTO KLADENÉ DOTAZY

What voltage and current ratings does the VIOX HR17 690VAC 400A Horizontal 3P Fuse Switch Disconnector support?

This VIOX HR17 series is rated for 690VAC with a current rating of 400A and High Breaking Capacity breaking performance. Refer to the technical specification table above for individual part numbers and ampere steps.

Which international standards apply to VIOX HR17 690VAC 400A Horizontal 3P Fuse Switch Disconnector?

The HR17 series is designed and verified to IEC 60269 requirements for safe overcurrent and short-circuit protection.

Where is the VIOX HR17 690VAC 400A Horizontal 3P Fuse Switch Disconnector typically installed?

It is engineered for hrc fuse switch disconnector circuits, protecting cables, busbars, semiconductors, battery modules, or string feeders against thermal overload and high-energy short-circuit faults.

Can VIOX supply matched fuse holders, bases, or OEM private-label packaging?

Yes. VIOX Electric supplies matched DIN-rail fuse holders, NH/NT fuse bases, disconnectors, and OEM/ODM bulk packaging with technical datasheets upon RFQ.

Potřebujete cenovou nabídku produktu?
Pojďme to vybudovat společně.

Zašlete nám model produktu, technické parametry, množství a požadavky OEM. Náš tým vaši žádost posoudí a odpoví do jednoho pracovního dne.

Požádat o cenovou Nabídku