One VIOX system. Every application.

Protection, switching and distribution for residential, industrial, solar, data, panel and marine projects.

Conceptual 3D industrial park with residential buildings, a factory, solar and storage, a data center, a central distribution frame, an EV charging court, and a marine dock

Explore the applications below.

Aplicações

Edifícios de habitação

Residential distribution boards bring together protection for lighting, socket outlets, kitchens and climate-control circuits. MCBs provide overload and short-circuit protection; RCCBs provide residual-current protection and require coordinated overcurrent protection; RCBOs combine these functions at the circuit level. Choose the current rating, tripping curve, pole configuration and breaking capacity for each circuit. Select the residual-current type for the connected equipment rather than treating Type B or EV variants as a default requirement for every home. Separating final circuits can limit disruption from a fault, while continuity still depends on upstream coordination. Surge protective devices address transient overvoltages and do not replace circuit breakers. Prepare the supply details, circuit schedule, destination market, required documents, board-space limits and order scope before confirming a model.

Energia Solar e Armazenamento de Energia

PV strings, combiner boxes, DC isolation and surge protection form different parts of the solar power path. A correctly specified gPV fuse and compatible holder protect individual strings, while a PV surge protective device limits transient overvoltage through a coordinated path to earth. A DC isolator provides a defined manual isolation point. Confirm voltage, current, pole arrangement, earthing and interruption requirements against the array design and the selected device. Review the complete combiner assembly and its model-specific component list before ordering. Battery-side protection is a separate design decision: bidirectional current, maximum DC voltage, prospective fault current and the battery or PCS instructions must be checked before using a PV-oriented component. Share the system architecture, string layout, environmental exposure, quantity and document requirements to prepare a product request.

Automação industrial

Industrial control components sense conditions, manage timing, switch loads and protect circuits within a defined machine operating sequence. A contactor operates the load in response to the control circuit; confirm motor duty, utilization category, coil voltage and switching frequency together with overload and short-circuit protection. Proximity sensors require a match between target material, sensing distance, supply voltage and controller input. Timer relays require the operating mode, trigger, reset behavior, time range and output contact duty to be specified. Cabinet thermostats control selected heating or cooling arrangements within their declared switching and temperature limits. Machine interlocks and controller logic remain part of the control-system design. Prepare the power supply, control voltage, load data, sensing requirements, panel environment and order scope before selecting individual components.

Centros de Dados e Telecomunicações

Data center and telecom power systems coordinate source transfer, monitoring, surge protection and auxiliary distribution around the actual electrical design. Normal and alternate supplies, transfer equipment, distribution, UPS architecture and downstream loads form a wider system; UPS and rack PDU nodes are context, not presented as VIOX products. Automatic transfer switches manage defined source changes, monitoring relays provide control signals, and AC surge protective devices limit transient overvoltage at coordinated positions. MCBs protect selected branch circuits, while distribution blocks and terminal blocks organize conductors. Confirm source arrangement, neutral treatment, interlocking, fault level and protection boundaries. Follow the UPS manufacturer's requirements at its interfaces. Share system ratings, monitoring thresholds, control voltage, earthing, panel conditions and model-document needs before confirming a component shortlist.

Elétrica Marítima e Externa

Outdoor equipment protection depends on the enclosure, lid, cable entries, closures and any specified vent working together. Match cable glands to cable outside diameter, cable count, thread type, wall thickness and strain-relief requirements. Select enclosure material, usable space, lid seal and mounting arrangement for the complete installation. A breather vent may support pressure equalization where the enclosure design calls for it, but does not guarantee freedom from condensation. Keep conductor terminations accessible for inspection and resealing. Sheltered cabinets, coastal equipment, wet industrial areas and temporary outdoor power face different exposure conditions. Review rain, dust, sunlight, chemicals, corrosion and vibration, and verify any required marine approvals for the exact model. Provide electrical ratings, cable sizes, exposure conditions, quantities and destination requirements for product review.

Montagem de Painéis e Distribuição de Energia

Low-voltage panel building organizes incoming conductors, main distribution, branch protection, modular mounting and outgoing terminals into a defined current path. Distribution blocks split conductors, busbar assemblies support distribution, DIN rails mount compatible components, and terminal blocks provide identified outgoing connections. Assign each zone a clear function and confirm conductor material, cross-section, connection method and service access. Protective devices require coordinated ratings, pole arrangements, neutral treatment and compatible busbar interfaces. Mechanical selection includes enclosure space, mounting profiles, busbar supports and clearances. The panel builder remains responsible for complete design, protection coordination, temperature-rise assessment, short-circuit performance and applicable documentation; a component layout is not assembly verification. Share the single-line concept, electrical system, current paths, dimensions, product quantities and destination market before confirming the component list.

Application questions

Planejando um projeto residencial ou linha de produtos?

Compartilhe seu cronograma de circuitos ou requisitos de fornecimento com VIOX.

Source: applications/residential-buildings

Planejando um sistema solar PV ou de bateria DC?

Compartilhe a tensão do sistema, corrente, layout da string, escopo de proteção, ambiente de instalação e mercado-alvo com VIOX.

Source: applications/solar-energy-storage

A construir um painel de controlo industrial?

Compartilhe a carga, tensão de controle, sequência de operação, requisitos de detecção e escopo do pedido com VIOX.

Source: applications/industrial-automation

Definindo um painel de energia de data center ou telecomunicações?

Compartilhe o arranjo da fonte, classificações elétricas, funções de monitoramento, limites de proteção, mercado do projeto e escopo do pedido com VIOX.

Source: applications/data-centers-telecom

Planejando um invólucro elétrico externo?

Envie os tamanhos dos cabos, detalhes do invólucro, condições de exposição e quantidades. VIOX ELECTRIC pode ajudar a restringir as opções de componentes.

Source: applications/marine-outdoor-electrical