VIOX 690VAC 100A NH000 HRC Fuse

NH000 China fuse manufacturer VIOX 690VAC 100A NH000 HRC Fuse primarily protects cables and conductors against overload and short-circuit currents and is also suitable for the protection of equipment with different operating classes such as gG/gL, aM and aR. This square body with.

Serie VIOX
NH000
Tensione nominale
690VAC
Corrente nominale
100A
Standard
IEC60269-1 / IEC60269-2

Panoramica

NH000 China fuse manufacturer VIOX 690VAC 100A NH000 HRC Fuse primarily protects cables and conductors against overload and short-circuit currents and is also suitable for the protection of equipment with different operating classes such as gG/gL, aM and aR. This square body with blade terminals fuse was made in a standardized configuration for global acceptance. 690VAC 100A NH00C HRC Fuse is available in multiple ampere ratings from 4A up to 100A, which helps match specific requirements in various industrial applications, such as motors, transformers, low voltage distribution, control circuits, etc.

Caratteristiche

  • IEC60269-1
  • IEC60269-2
  • gG/gL
  • Covering 500VAC, 690VAC, 800VAC and 1140VAC electrical distribution circuits and various industrial applications
  • 4-100A ampere ratings available
  • Full range protection
  • Meets IEC standards for global acceptance
  • Standardized square body with blade terminals construction

Specifiche tecniche

NH000 Technical Specifications

Model/Size Tensione nominale (V) Corrente nominale (A) Dimensione complessiva
A D E H H1 H2
NH00C 500/690 4, 6, 10, 16, 20, 25, 32, 40, 50, 63, 80, 100 78 52 21 53 15 35

NH000 Ratings & Dimensions Table 2

Model/Size Rated Voltage(V) Corrente nominale (A) Dimensione complessiva
YR:Sist101 690 160 Fig.2

Selection & Installation Notes

  • Verify system maximum voltage (690VAC) and prospective short-circuit fault current before selecting the fuse link or holder rating.
  • Apply ambient-temperature derating when operating inside sealed outdoor combiner boxes or high-density inverter cabinets above 40°C.
  • Always de-energize circuits before replacing cylindrical, blade, or bolted fuse links, and use insulated fuse pullers for NH/NT types.
  • Explore the complete VIOX Fuse & Fuse Holder catalog for matched holders, bases, and disconnectors.

FAQ

What voltage and current ratings does the VIOX 690VAC 100A NH000 HRC Fuse support?

This VIOX NH000 series is rated for 690VAC with a current rating of 100A and High Breaking Capacity breaking performance. Refer to the technical specification table above for individual part numbers and ampere steps.

Which international standards apply to VIOX 690VAC 100A NH000 HRC Fuse?

The NH000 series is designed and verified to IEC60269-1 / IEC60269-2 requirements for safe overcurrent and short-circuit protection.

Where is the VIOX 690VAC 100A NH000 HRC Fuse typically installed?

It is engineered for low-voltage hrc industrial fuse circuits, protecting cables, busbars, semiconductors, battery modules, or string feeders against thermal overload and high-energy short-circuit faults.

Can VIOX supply matched fuse holders, bases, or OEM private-label packaging?

Yes. VIOX Electric supplies matched DIN-rail fuse holders, NH/NT fuse bases, disconnectors, and OEM/ODM bulk packaging with technical datasheets upon RFQ.