Fuse Holder & HR17 Disconnector Manufacturer (RT18 DIN-Rail · VOPV 1500V DC Solar Holders · NH Bases · HR17 160–630A)
UL94 V-0 flame-retardant DIN-rail fuse holders with high-tension copper-alloy clips, LED blown-fuse indication, heavy-duty NH/3L solar bases, and IEC 60947-3 HR17 load-break fuse switch disconnectors.
Explore All VIOX Fuse Holders & HR17 Disconnectors Series
Click any ampere or voltage rating pill below to open its full IEC technical specification table and dimensional datasheet.
HR17 Horizontal 3P Disconnector
4-frame AC-22B/23B load-break NH fuse switch (160A–630A)
RT18-32 Cylindrical Link & Holder
Control panel, PLC & SPD backup 10×38 mm link + DIN holder
- Tensione
- 500 V AC
- Attuale
- 1–32 A
- Standard
- IEC 60269-2 · gG/aM
RT18-63 Cylindrical Link & Holder
Sub-feeder & motor control 14×51 mm link + DIN holder
- Tensione
- 500 V AC
- Attuale
- 2–63 A
- Standard
- IEC 60269-2 · gG/aM
RT18L-125 Cylindrical Link & Holder
High-amp cylindrical 22×58 mm HRC link + DIN holder
- Tensione
- 500 V AC
- Attuale
- 16–125 A
- Standard
- IEC 60269-2 · gG/aM
VOPV-30 / 30X String Series
1000V / 1100V / 1500V DC · 30 A · Link, DIN Holder & LED
- Tensione
- 1000–1500 V DC
- Attuale
- 1–30 A
- Standard
- IEC 60269-6 · gPV
VOPV-30L 1500V String Series
Extended 85 mm ceramic arc tube for 1500V DC PV strings
- Tensione
- 1000 / 1500 V DC
- Attuale
- 2–30 A
- Standard
- IEC 60269-6 · gPV
VOPV-40 Sub-Array Series
Thermal-protected 14×51 mm PV links & DIN holders
- Tensione
- 1000 / 1500 V DC
- Attuale
- 10–40 A
- Standard
- IEC 60269-6 · gPV
VOPV-63 High-Amp String
14×65 mm cylindrical PV links & matched DIN holders
- Tensione
- 1000 / 1500 V DC
- Attuale
- 15–63 A
- Standard
- IEC 60269-6 · gPV
VOPV-160 / VOPV-250 Blade Series
Combiner-box main NH0 (160A) & NH1XL (250A) links & bases
- Tensione
- 1000 / 1500 V DC
- Attuale
- 50–250 A
- Standard
- IEC 60269-6 · gPV
VOPV-400 / VOPV-630 Main Array
Heavy-duty NH2XL striker & 3L bolt/blade PV links & bases
- Tensione
- 1000 / 1500 V DC
- Attuale
- 200–630 A
- Standard
- IEC 60269-6 · gPV
Match Your DIN-Rail Fuse Holder, PV Base or Load-Break HR17 Disconnector
Select your application tier and current range to match the exact VIOX series, mounting base, and safety verification rule.
Protection Physics & 4 Field Failure Modes in Fuse Holders & HR17 Disconnectors
Technical architecture and field-proven failure prevention engineered directly into VIOX production.
Failure Mode 01 · Holder Melts While Fuse Link Stays Intact
Weak spring clips and loose lugs create localized I²R heat that melts cheap plastic carriers. VIOX Fix: High-tension copper-alloy clips & UL94 V-0 housings across RT18 & VOPV.
Failure Mode 02 · Arc Flash From Opening DIN Holders Under Load
Operators mistakenly treat DIN fuse carriers like switches without arc-quenching chambers. VIOX Fix: Upgrade 160A–630A feeders to HR17 3P Load-Break Fuse Switch Disconnectors.
Holder Melts While Fuse Link Stays Intact
Weak spring clips and loose lugs create localized I²R heat that melts cheap plastic carriers.
Arc Flash From Opening DIN Holders Under Load
Operators mistakenly treat DIN fuse carriers like switches without arc-quenching chambers.
Combiner Box Overheating Without Derating
Tightly banked DIN holders in 60°C solar boxes exceed thermal dissipation limits.
Slow Troubleshooting in Multi-String Cabinets
Without visual fault indication, technicians must probe dozens of live strings manually.
Fuse Holder & Disconnector Cross-Reference vs. Bussmann, Mersen & Siemens
Direct mechanical and IEC standard cross-reference for panel builders, EPCs, and distributors converting Tier-1 BOMs.
| Footprint / Rating Tier | Eaton Bussmann | Mersen / Ferraz | Siemens / Littelfuse | VIOX Direct Equivalent |
|---|---|---|---|---|
| 10×38 mm AC DIN Holder (32A) | Bussmann CH10 |
Mersen US10 |
Siemens 3NW70 / Littelfuse LPSC |
VIOX RT18-32 DIN Holder |
| 14×51 mm AC DIN Holder (63A) | Bussmann CH14 |
Mersen US14 |
Siemens 3NW71 / Littelfuse LPHV |
VIOX RT18-63 DIN Holder |
| 22×58 mm AC DIN Holder (125A) | Bussmann CH22 |
Mersen US22 |
Siemens 3NW72 |
VIOX RT18L-125 DIN Holder |
| 1000V–1500V DC Solar PV Holder | Bussmann CHPV1U / CHPV15 |
Mersen US10M / US15M |
Littelfuse LPHV / LFXV |
VIOX VOPV-30 / VOPV-30X (LED) / VOPV-30L |
| Horizontal 3P NH Switch (160–630A) | Bussmann NH Disconnector |
Mersen Multibloc® |
Siemens 3NP1 |
VIOX HR17 160A / 250A / 400A / 630A |
I²t, breaking capacity, and project UL/IEC certification before substitution. Send your Tier-1 BOM via the RFQ builder below for rapid VIOX engineering verification.
Configure Your Fuse Holders & HR17 Disconnectors Specification in 20 Seconds
Select your technical options below and prefill the VIOX engineering quote form with one click.
Fuse Holders & HR17 Disconnectors Technical FAQ
Direct answers on standards, sizing, Tier-1 interchangeability, and factory OEM kitting.
Load-Break What is the difference between a DIN fuse holder and an HR17 fuse switch disconnector?
DIN-rail fuse holders (RT18, VOPV) are non-load-break isolation carriers without arc chutes and must only be opened when de-energized. HR17 horizontal 3P fuse switch disconnectors include integrated arc chutes rated for safe AC-22B/23B load-break switching from 160 A to 630 A.
LED Option Do VIOX 1000V and 1500V DC solar fuse holders support blown-fuse LED indicators?
Yes. The VOPV-30X series provides integrated neon/LED blown-fuse indication across 1000V DC, 1100V DC, and 1500V DC 10×38 mm DIN-rail fuse holders.
Melting Why do fuse holders melt even when the fuse link inside is still intact?
Localized I²R contact heat from loose terminal screws, undersized wire gauges, or weak spring clips raises terminal temperatures above housing limits. VIOX uses high-tension copper-alloy clips and UL94 V-0 housings to prevent thermal runaway.
Compatibilità Are VIOX RT18 holders compatible with Bussmann CH10/CH14/CH22 footprints?
Yes. VIOX RT18-32 (10×38 mm), RT18-63 (14×51 mm), and RT18L-125 (22×58 mm) mount on standard 35 mm EN 60715 DIN rails and accept IEC 60269-2 cylindrical links.
Need Fuse Holders & HR17 Disconnectors Datasheets or BOM Cross-Ref?
Talk Directly with VIOX Engineers.
Send your rated voltage, ampere steps, breaking capacity, or Tier-1 part numbers for rapid factory pricing and evaluation samples.
Request Fuse Holders & HR17 Disconnectors Quote