Rotary Cam Switches & Load Disconnect Switches (LW26 / LW30) 10A–160A Universal Cam Switches (ON-OFF, Changeover 1-0-2, Motor Reversing, Selector) & 20A–125A Main Isolators
VIOX Electric manufactures heavy-duty LW26 rotary cam switches (10A–160A, up to 12 contact decks) and LW30 load disconnect switches (20A–125A, IP65 padlockable) engineered for switchgear panels, three-phase motor reversing, manual generator changeover, and industrial machine control.
What Is a Rotary Cam Switch? (LW26 vs. LW30 Overview)
A sakelar cam putar (juga disebut sakelar cam atau industrial rotary switch) is a multi-pole mechanical switching device whose central shaft rotates profiled insulating cams to open and close stacked double-break silver-alloy contacts in an exact programmed sequence. Unlike single-function toggle switches, one compact panel-mounted cam switch executes complex ON-OFF, 1-0-2 changeover, motor reversing, or voltmeter selection logic.
Within VIOX’s low-voltage switching portfolio, the LW26 rotary cam switch handles custom multi-deck control and power transfer from 10A to 160A, while the LW30 load disconnect switch provides dedicated 20A–125A main-panel AC-23A load breaking with padlockable emergency handles and door-interlock shafts. For solar PV DC isolation, pair with our Solar DC Isolator Switch Hub.
- Positive Double-Break Action: Two contact gaps per pole quench AC-23A / AC-3 inductive arcs rapidly.
- Modular Deck Stacking: Combine 1 to 12 independent wafers (up to 24 contacts) on one 48–88 mm bezel.
- Padlockable Lockout-Tagout: Red-yellow emergency OFF handles accept up to 3 safety padlocks.
- Visual Panel Status: Padukan dengan Indikator Posisi Sakelar VIOX on mimic switchboards.
4 Core Switching Functions: ON-OFF, Changeover, Motor Reversing & Selector
Every industrial rotary cam switch is defined by its switching program. Select from four standard factory-stocked topologies or submit a custom contact chart.
ON-OFF Cam Switch & Main Load Isolator
Simultaneously breaks 1P, 2P, 3P, 4P, or 6P power circuits across a positive 90° throw. Specify LW30 (20A–125A) or LW26 (10A–160A) with IP65 front seals and padlockable red-yellow handles for IEC 60204-1 machine main disconnects.
Manual Changeover Cam Switch (Mains / Generator)
Break-before-make center-OFF transfer switching between two power sources or two load banks without cross-feeding. Need automated unmanned transfer? Compare against our Automatic Transfer Switch (ATS) Hub.
Three-Phase Motor Reversing Cam Switch
Swaps phases L1 and L3 internally through factory copper jumpers across 3 contact decks to reverse three-phase hoists, lathes, and conveyors cleanly through a mandatory center-OFF pause. Also available in 2-speed Dahlander and star-delta starter programs.
Rotary Cam Selector Switch (Voltmeter & Ammeter)
Monitors all three line-to-line (L1-L2, L2-L3, L3-L1) and phase-to-neutral voltages using a single panel meter, or switches three CT secondaries with make-before-break shorting bridges so current transformers never open-circuit under load.
Compare VIOX LW26 Cam Switches & LW30 Load Disconnect Switches
Compare our two core industrial rotary platforms side-by-side and inspect full product datasheets below.
VIOX LW26 Rotary Cam Switch (10A–160A)
LW26 · Universal Rotary Cam Switch- Thermal Current (Ith)
- 10A, 20A, 25A, 32A, 63A, 125A, 160A
- Kategori Pemanfaatan
- AC-21A / AC-23A / AC-3 / AC-15
- Switching Programs
- ON-OFF, 1-0-2, Reversing, Selector
- Opsi Pemasangan
- 48×48 / 64×64 / 88×88 mm Panel / Box
VIOX LW30 Load Disconnect Switch (20A–125A)
LW30 · Main Load Disconnect Switch- Thermal Current (Ith)
- 20A, 25A, 32A, 40A, 63A, 80A, 100A, 125A
- Kategori Pemanfaatan
- IEC 60947-3 AC-21A / AC-22A / AC-23A
- Switching Programs
- 3P / 4P / 6P Main ON-OFF (0–1 · 90°)
- Opsi Pemasangan
- DIN Rail, Base Mount & Door Interlock
| Spesifikasi | Sakelar Cam Putar LW26 | Sakelar Pemutus Beban LW30 |
|---|---|---|
| Rated Thermal Current (Ith) | 10A, 20A, 25A, 32A, 63A, 125A, 160A | 20A, 25A, 32A, 40A, 63A, 80A, 100A, 125A |
| Tegangan Isolasi Terukur (Ui) | 690V AC (50/60 Hz) | 690V AC (IEC 60947-3) |
| Kategori Pemanfaatan | AC-21A, AC-23A, AC-3 (Motor), AC-15 (Control) | AC-21A, AC-22A, AC-23A (Main Load Break) |
| Poles & Contact Decks | 1 to 12 decks (2–24 contacts, custom programs) | 3P, 4P, 6P + optional auxiliary NO/NC blocks |
| Front Escutcheon / Cutout | 48×48 mm (10–25A) · 64×64 mm (32–63A) · 88×88 mm (125–160A) | 48×48 mm / 64×64 mm · 4-hole, single-hole Ø22.5 mm, DIN rail & door shaft |
| Perlindungan Masuknya Air (IP) | IP20 terminals · IP40 / IP65 front bezel seal | IP20 finger-safe terminals · IP65 padlockable handle / IP65 box |
| Aplikasi Khas | Motor reversing, 1-0-2 changeover, voltmeter/ammeter selector, welders | Switchboard main isolator, machine tool emergency OFF, motor local disconnect |
How to Specify a Cam Switch (Switching Program, Current, Poles & Mounting)
Select your switching function and load current below to match the exact LW26 or LW30 configuration, or review our cam switch switching-program guide dan step-by-step cam switch wiring diagrams.
| Switching Program | Handle Positions | Indexing Angle | Contact Decks (3-Phase) | Rekomendasi Seri VIOX |
|---|---|---|---|---|
| ON-OFF Main Isolator | 0 – 1 (2 Positions) | 90° (or 60°) | 2 Decks (3P / 4P) | LW30 (20A–125A) · LW26 (10A–160A) |
| Changeover Switch | 1 – 0 – 2 (Center OFF) | 60° (or 45°) | 3–4 Decks (3P / 4P) | LW26 (Manual) · ATS (Auto) |
| Motor Reversing | 1 – 0 – 2 (Fwd-OFF-Rev) | 60° | 3 Decks (with L1/L3 jumpers) | LW26 (10A–63A AC-3 Motor Duty) |
| Voltmeter / Ammeter Selector | 0–L1L2–L2L3–L3L1 (4–7 Pos.) | 45° or 30° | 2–3 Decks (CT shorting opt.) | LW26-20 (10A / 20A Instrument) |
Industrial Applications & Panel Integration
1. Switchboard Main Load Isolation
LW30 3P/4P load disconnectors with door-interlock extended shafts prevent enclosure doors from opening while energized, meeting IEC 60204-1 safety rules on MCCs and distribution panels.
2. Three-Phase Motor Reversing & Multi-Speed Control
LW26 reversing and Dahlander cam switches provide direct-on-line forward/reverse and 2-speed control for hoists, wood-working machinery, mixers, and industrial exhaust fans.
3. Voltmeter & Ammeter Panel Instrumentation
Compact 48×48 mm LW26-20 selector switches replace three separate meters with one multi-phase selector, complete with make-before-break CT shorting decks for safe ammeter switching.
4. Welding Machines & OEM Control Consoles
High-endurance multi-step LW26 cam stacks switch transformer tap windings on MIG/TIG welders, battery chargers, and CNC auxiliary circuits across 50,000+ mechanical cycles.
Inside VIOX Cam Switch Manufacturing, Silver-Alloy Contacts & OEM Customization
Real VIOX workshop views showing LW26 and LW30 rotary cam switches moving from staged mechanisms through bench assembly to completed inspection batches.



Diagram Pengkabelan Sakelar Cam: Panduan Instalasi Langkah demi Langkah
Terminal jumper layouts for 3-phase ON-OFF, 1-0-2 changeover, and motor reversing.
Explore Guide →How to Read a Cam Switch Switching Program (X-Table)
Decode cam angles, deck positions, and contact closure charts before ordering.
Explore Guide →Cam Switch Technical Guide & Selection Criteria
Match AC-21A, AC-23A, and AC-3 motor duty ratings to panel enclosures.
Explore Guide →Cam Switch vs. Rotary Switch: Key Differences Explained
Why heavy-duty double-break cam stacks outperform light wafer rotary switches.
Explore Guide →Automatic Transfer Switches (ATS) vs. Manual 1-0-2 Changeover
Upgrade manual generator changeover to unmanned automatic dual-power switching.
Explore Guide →Solar DC Isolator Switches (1000V–1500V DC-PV2)
Need high-voltage PV DC load breaking? Explore our VOPV & UKPD DC isolators.
Explore Guide →Rotary Cam Switch Selection FAQ
LW26 vs. LW30 What is the difference between a VIOX LW26 rotary cam switch and an LW30 load disconnect switch?
LW26 is a multi-deck universal rotary cam switch (10A–160A) engineered for custom switching programs including 1-0-2 manual changeover, three-phase motor reversing, multi-speed Dahlander control, and voltmeter/ammeter selection. LW30 (20A–125A) is a dedicated IEC 60947-3 main load-break isolator (0–1, 90°) with padlockable red-yellow handles and door-interlock shafts for switchgear mains.
Motor Reversing How do I size a motor reversing cam switch for a three-phase induction motor?
Always size a motor reversing cam switch by its IEC 60947-3 AC-3 (motor load) kW/current rating rather than its higher AC-21A resistive thermal current (Ith). Use a 3-position 1-0-2 center-OFF program (60° indexing) so the operator pauses briefly at 0 before reversing two supply phases, preventing high plugging-current arcs across the silver-alloy contacts.
Manual vs. ATS When should I use a 1-0-2 changeover cam switch instead of an Automatic Transfer Switch (ATS)?
Choose an LW26 1-0-2 manual changeover cam switch when a trained operator switches between utility and backup generator power on demand at low cost and compact panel depth. Choose a VIOX Automatic Transfer Switch (/ats/) when unmanned power-failure detection and automatic millisecond-to-second transfer are required for hospitals, data centers, or critical pumps.
Custom Programs Can VIOX manufacture custom switching programs, contact decks, and laser-engraved escutcheon plates?
Yes. Send your contact closure table (X-table), switching angle (30°, 45°, 60°, or 90°), number of poles/decks (1 to 12 wafers), and desired front-plate markings. Our factory builds custom LW26 cam stacks with AgNi/AgCdO silver-alloy contacts and optional IP65 padlockable front seals from low OEM MOQs.
DC vs. AC Isolation Can an LW26 or LW30 AC rotary cam switch be used on 1000V–1500V solar PV DC strings?
No. Standard AC rotary cam switches and LW30 load disconnectors are rated for AC-21A/AC-23A up to 690V AC and low-voltage DC control circuits. For high-voltage 1000V–1500V solar PV arrays, always specify an IEC 60947-3 DC-PV2 rated VIOX Solar DC Isolator Switch (/dc-isolator-switch/).
Need Custom-Program LW26 Cam Switches or LW30 Load Disconnectors?
Share your switching diagram (X-table), rated current (10A–160A), panel cutout, and handle/IP65 requirements. VIOX engineers respond within 24 hours with drawings and OEM pricing.