DIN Rail Mini Aerosol Fire Extinguishers (QRR Series) 1P (18 mm) Self-Activating, Maintenance-Free Fire Suppression for Electrical Cabinets
Stop electrical cabinet fires at the source in seconds—with zero piping, zero pressurized tanks, and zero external power. VIOX manufactures ultra-compact 1P (84.5 × 18 × 60 mm) DIN-rail QRR mini aerosol generators (10g / 20g / 30g covering ≤ 0.4 m³ to ≤ 1.2 m³) and Smart Wireless / RS485 BMS-ready suppression units.
Choose a VIOX Aerosol Fire Extinguisher for Your Electrical Cabinet
Select standalone 1P thermal-cord units for compact distribution boards and EV chargers, or Smart Wireless / RS485 Modbus RTU units for BESS, server racks, and switchgear.
QRR-0.01G (-2/10 R LT) · 1P Red
Best Seller · 1P 18 mm DIN Rail- Dosage
- 10g / 20g Solid Aerosol
- Cakupan
- Protects ≤ 0.4 m³ to ≤ 0.8 m³
- Dimensi
- 84.5 × 18 × 60 mm (1P Width)
- Pemasangan
- 35 mm DIN Rail / 3M Magnetic
QRR-0.01G/S-1/10B · 1P Black
Ultra-Compact · Thermal Self-Trigger- Dosage
- 10g / 20g Solid Aerosol
- Cakupan
- Protects ≤ 0.4 m³ to ≤ 0.8 m³
- Dimensi
- 84.5 × 18 × 60 mm (1P Width)
- Pemasangan
- 35 mm DIN Rail / 3M Magnetic
QRR-0.03GW-230R · 30g High-Capacity
Medium Cabinet · Extended Coverage- Dosage
- 30g Solid Aerosol
- Cakupan
- Protects up to ≤ 1.2 m³
- Dimensi
- Compact Enclosure Generator
- Pemasangan
- DIN Rail / Screw / Magnetic
Smart Wireless Fire Suppression Device
Standard IoT · Sound & Light Alarm- Dosage
- External Magnetic Extinguisher Head
- Cakupan
- Multi-Zone Large Cabinets
- Dimensi
- DIN Rail Controller + External Head
- Pemasangan
- DIN Controller + Magnetic Nozzle
Smart Fire Suppression (RS485 Series)
BMS / SCADA Ready · Modbus RTU- Dosage
- Multi-Zone Modular Aerosol Head
- Cakupan
- BESS, Data Centers & Switchgear
- Dimensi
- RS485 Telemetry + Fire Feedback
- Pemasangan
- DIN Rail + Dry-Contact Output
Smart Fire Suppression (4G IoT Type)
4G Remote Cloud · 24/7 Alerting- Dosage
- Multi-Zone Modular Aerosol Head
- Cakupan
- Unmanned Telecom & Solar Sites
- Dimensi
- Built-In 4G Module + Local Alarm
- Pemasangan
- DIN Rail Controller + Magnetic Head
| Model / Series | Dosis Agen | Volume Terlindungi | Activation Mode | Mounting & Size | Best-Fit Enclosures |
|---|---|---|---|---|---|
| QRR-0.01G (-2/10 R LT) | 10g / 20g | ≤ 0.4 m³ – ≤ 0.8 m³ | 170°C Thermal Cord (No Power) | 1P DIN Rail (84.5×18×60 mm) / 3M | Distribution boards, PLC boxes, EV wallboxes |
| QRR-0.01G/S-1/10B (Black) | 10g / 20g | ≤ 0.4 m³ – ≤ 0.8 m³ | 170°C Thermal Cord (No Power) | 1P DIN Rail (84.5×18×60 mm) / 3M | Solar combiner boxes, telecom & server racks |
| QRR-0.03GW-230R | 30g | ≤ 1.2 m³ | Thermal Cord / Electric Option | DIN Rail / Screw / Magnetic | Industrial control panels, inverter cabinets |
| Smart Wireless Series | Multi-Zone | Large Cabinets | Thermal + Wireless Cloud + Alarm | DIN Controller + Magnetic Head | Commercial switchgear, remote utility sites |
| RS485 Modbus RTU Series | 10g–30g+ | BESS & Switchgear | Thermal + RS485 BMS Feedback | DIN Rail + Dry-Contact Output | Battery energy storage (BESS), data centers |
Calculate Required Aerosol Dosage & Unit Count for Your Cabinet
Set your cabinet height, width, and depth in millimeters—our calculator computes exact internal volume (m³) and matches the right VIOX QRR dosage per factory coverage ratings.
How 1P DIN Rail Aerosol Stops Cabinet Fires — Without Damaging Electronics
See how VIOX QRR snaps directly beside MCBs inside an actual distribution cabinet, then compare condensed solid aerosol against traditional fire suppression.
-
1
Incipient Arc or Overheat Reaches 170°CA loose terminal, overloaded breaker, or DC arc raises local temperature inside the sealed enclosure.
-
2
Thermal Cord Auto-Triggers (Zero Power)The 170°C heat-sensitive cord ignites the solid aerosol compound instantaneously—even during a complete blackout.
-
✓
5–10s Non-Conductive Suppression · Zero Water DamageUltra-fine potassium radicals break the flame chain chemically without shorting PLCs, relays, or copper busbars.
Manual Dry Powder / CO₂ Extinguishers
DELAYED · MESSYVIOX 1P DIN Rail Solid Aerosol (QRR)
AUTOMATIC · ZERO RESIDUEInside the VIOX Aerosol Fire Extinguisher Production Line
Direct factory assembly, thermal-cord calibration, batch discharge verification, and private-label OEM packaging for panel builders and fire-safety distributors.
1. Non-Pressurized Solid Core
Zero pressure cylinder testing or leakage risk—safe for sea/air logistics handling and 10-year maintenance-free cabinet standby.
2. 170°C Thermal Cord Calibration
Batch-verified ignition temperature prevents false alarms in hot 70°C rooftop solar boxes while triggering instantly on real flame.
3. Non-Conductive & Eco-Safe
Zero ozone depletion (ODP = 0), zero global warming potential (GWP = 0), and safe around live switchgear electronics.
4. Private-Label OEM Ready
Custom model codes, laser logo printing, 10–50 cm thermal cord lengths, and mixed shipments with MCB & AFDDs.
Configure Your Cabinet Fire Extinguisher Quote in 30 Seconds
Select series type, dosage capacity, mounting hardware, and OEM options—copy or attach directly to VIOX factory sales.
DIN Rail Aerosol Extinguisher Sizing, Retrofit & Technical Guides
In-depth engineering articles explaining 1P aerosol generators, volume sizing, and comparisons against gas and dry powder systems.
What Is a 1P DIN Rail Aerosol Generator?
How an 18 mm wide DIN-rail module suppresses electrical cabinet fires automatically without piping or power.
Explore Guide →How to Choose the Right Size Aerosol Extinguisher for Enclosures
Enclosure volume formulas, 10g/20g/30g coverage tables, and ventilation derating rules.
Explore Guide →Retrofitting Old Control Panels with DIN Rail Fire Extinguishers
Snap-on 5-minute fire protection upgrades for legacy switchgear, EV chargers, and telecom cabinets.
Explore Guide →Why Solid Aerosol Is Better Than Gas for Small Enclosures
Compare non-pressurized solid aerosol against CO₂ and FM200 clean-agent cylinders.
Explore Guide →Aerosol Fire Extinguishing Device vs. Traditional Extinguishers
Residue, conductivity, maintenance cost, and response time compared across fire suppression technologies.
Explore Guide →Alat Pemadam Api Aerosol Rel DIN untuk Kabinet Listrik
Full product guide covering QRR thermal triggers, RS485 BMS telemetry, and mounting clearances.
Explore Guide →DIN Rail Aerosol Fire Extinguisher Selection & Safety Questions
Prinsip Kerja How does a 1P DIN rail aerosol fire extinguisher activate without external power?
VIOX QRR Mini DIN rail aerosol extinguishers use an integrated thermal detection cord calibrated to ~170°C. When an electrical arc or overheated breaker raises the internal cabinet temperature to the trigger threshold, the thermal cord automatically ignites the solid potassium-based aerosol compound—releasing an ultra-fine fire-suppressing cloud within seconds, requiring zero electricity, batteries, or external sensors.
Volume Sizing What enclosure volume do 10g, 20g, and 30g VIOX QRR aerosol extinguishers protect?
Per VIOX factory ratings for enclosed electrical cabinets, a 10g unit (QRR-0.01G) protects up to 0.4 m³, a 20g unit protects up to 0.8 m³, and a 30g unit (QRR-0.03G) protects up to 1.2 m³. For larger switchgear bays or BESS racks exceeding 1.2 m³, install multiple synchronized units or specify our Smart Wireless / RS485 multi-zone series.
Electronics Safety Will condensed aerosol discharge damage PLCs, MCBs, or cause short circuits?
No. Condensed aerosol extinguishing particles are electrically non-conductive, non-corrosive, and leave virtually zero wet residue—unlike water sprinklers or messy ABC dry chemical powder that corrode PCBs and relays. After extinguishing an incipient electrical fire, the cabinet can be ventilated and inspected immediately.
Instalasi How much DIN rail space is needed and where should I mount the unit?
The QRR-0.01G / QRR-0.01G/S mini series measures just 84.5 × 18 × 60 mm—occupying exactly 1 module (1P) on a standard 35 mm DIN rail right next to MCBs, RCBOs, and SPDs. It also supports 3M magnetic or screw mounting. Position the unit near the upper half of the enclosure with the discharge nozzle unobstructed.
Kehidupan Pelayanan Does a DIN rail aerosol fire extinguisher require annual pressure inspections?
No. Because the extinguishing agent is stored as a stable solid compound inside a non-pressurized housing, there is zero risk of gas leakage and no pressurized cylinder testing required. VIOX QRR units provide up to 10 years of maintenance-free standby protection.
Smart BMS / RS485 Can VIOX aerosol extinguishers send a fire alarm signal to our BMS or SCADA system?
Yes. Our Smart Wireless and RS485 (Modbus RTU) series provide real-time fire feedback dry contacts, integrated sound-and-light local alarms, and cloud/BMS telemetry so facility operators are alerted the instant a cabinet fire is suppressed.
Need DIN Rail Aerosol Extinguisher Samples, MSDS or OEM Pricing?
Share your cabinet dimensions, target quantity, and whether you need standalone thermal units or RS485 BMS telemetry. VIOX factory engineers reply with datasheets, test reports, and tiered pricing within 24 hours.