VIOX ELECTRIC
Bahasa
Direct Factory · 1P DIN-Rail & Smart RS485 Automatic Cabinet Fire Suppression

DIN Rail Mini Aerosol Fire Extinguishers (QRR Series) 1P (18 mm) Self-Activating, Maintenance-Free Fire Suppression for Electrical Cabinets

Stop electrical cabinet fires at the source in seconds—with zero piping, zero pressurized tanks, and zero external power. VIOX manufactures ultra-compact 1P (84.5 × 18 × 60 mm) DIN-rail QRR mini aerosol generators (10g / 20g / 30g covering ≤ 0.4 m³ to ≤ 1.2 m³) and Smart Wireless / RS485 BMS-ready suppression units.

10g / 20g / 30gProtects ≤ 0.4 – 1.2 m³
170°C Auto-TriggerZero Power · 10-Yr Standby
1P · 18 mm WideSnaps Next to MCBs & SPDs
VIOX QRR Mini DIN Rail and Smart RS485 Aerosol Fire Extinguishers for Electrical Cabinets
01 · QRR Mini DIN-Rail & Smart RS485 Series

Choose a VIOX Aerosol Fire Extinguisher for Your Electrical Cabinet

Select standalone 1P thermal-cord units for compact distribution boards and EV chargers, or Smart Wireless / RS485 Modbus RTU units for BESS, server racks, and switchgear.

Technical comparison: VIOX QRR Mini DIN-Rail vs. Smart Wireless & RS485 Aerosol Fire Extinguishers
Model / Series Dosis Agen Volume Terlindungi Activation Mode Mounting & Size Best-Fit Enclosures
QRR-0.01G (-2/10 R LT)10g / 20g≤ 0.4 m³ – ≤ 0.8 m³170°C Thermal Cord (No Power)1P DIN Rail (84.5×18×60 mm) / 3MDistribution boards, PLC boxes, EV wallboxes
QRR-0.01G/S-1/10B (Black)10g / 20g≤ 0.4 m³ – ≤ 0.8 m³170°C Thermal Cord (No Power)1P DIN Rail (84.5×18×60 mm) / 3MSolar combiner boxes, telecom & server racks
QRR-0.03GW-230R30g≤ 1.2 m³Thermal Cord / Electric OptionDIN Rail / Screw / MagneticIndustrial control panels, inverter cabinets
Smart Wireless SeriesMulti-ZoneLarge CabinetsThermal + Wireless Cloud + AlarmDIN Controller + Magnetic HeadCommercial switchgear, remote utility sites
RS485 Modbus RTU Series10g–30g+BESS & SwitchgearThermal + RS485 BMS FeedbackDIN Rail + Dry-Contact OutputBattery energy storage (BESS), data centers
02 · Interactive Enclosure Volume (L × W × H) & Dosage Calculator

Calculate Required Aerosol Dosage & Unit Count for Your Cabinet

Set your cabinet height, width, and depth in millimeters—our calculator computes exact internal volume (m³) and matches the right VIOX QRR dosage per factory coverage ratings.

800 mm
600 mm
400 mm
4. Monitoring & Alarm Requirement
03 · Real Cabinet Installation & Suppression Technology Comparison

How 1P DIN Rail Aerosol Stops Cabinet Fires — Without Damaging Electronics

See how VIOX QRR snaps directly beside MCBs inside an actual distribution cabinet, then compare condensed solid aerosol against traditional fire suppression.

REAL INSTALLVIOX QRR Mounted on 35 mm DIN Rail Inside Electrical Cabinet
5-Minute Snap-On Retrofit · Zero Piping
VIOX hot aerosol fire extinguishing device installed on DIN rail inside an electrical distribution cabinet
  1. 1
    Incipient Arc or Overheat Reaches 170°CA loose terminal, overloaded breaker, or DC arc raises local temperature inside the sealed enclosure.
  2. 2
    Thermal Cord Auto-Triggers (Zero Power)The 170°C heat-sensitive cord ignites the solid aerosol compound instantaneously—even during a complete blackout.
  3. ✓
    5–10s Non-Conductive Suppression · Zero Water DamageUltra-fine potassium radicals break the flame chain chemically without shorting PLCs, relays, or copper busbars.
LAB 01Fire Suppression Technology Comparison

Manual Dry Powder / CO₂ Extinguishers

DELAYED · MESSY

    VIOX 1P DIN Rail Solid Aerosol (QRR)

    AUTOMATIC · ZERO RESIDUE
      04 · Direct Factory Proof · Real Production Workshop & OEM Supply

      Inside the VIOX Aerosol Fire Extinguisher Production Line

      Direct factory assembly, thermal-cord calibration, batch discharge verification, and private-label OEM packaging for panel builders and fire-safety distributors.

      VIOX Aerosol Fire Extinguisher Production Line 01
      VIOX Aerosol Fire Extinguisher Assembly & QC 02
      VIOX QRR Thermal Cord & Housing Inspection 03
      VIOX Finished QRR DIN Rail Extinguisher Stock 04

      1. Non-Pressurized Solid Core

      Zero pressure cylinder testing or leakage risk—safe for sea/air logistics handling and 10-year maintenance-free cabinet standby.

      2. 170°C Thermal Cord Calibration

      Batch-verified ignition temperature prevents false alarms in hot 70°C rooftop solar boxes while triggering instantly on real flame.

      3. Non-Conductive & Eco-Safe

      Zero ozone depletion (ODP = 0), zero global warming potential (GWP = 0), and safe around live switchgear electronics.

      4. Private-Label OEM Ready

      Custom model codes, laser logo printing, 10–50 cm thermal cord lengths, and mixed shipments with MCB & AFDDs.

      05 · Interactive B2B Tool · 5-Step Aerosol Fire Extinguisher RFQ Builder

      Configure Your Cabinet Fire Extinguisher Quote in 30 Seconds

      Select series type, dosage capacity, mounting hardware, and OEM options—copy or attach directly to VIOX factory sales.

      1. Extinguisher Series
      2. Agent Dosage & Cabinet Coverage
      3. Mounting Method
      4. Thermal Cord / Feedback Option
      5. Supply & Branding
      06 · Electrical Cabinet Fire Protection Knowledge Hub

      DIN Rail Aerosol Extinguisher Sizing, Retrofit & Technical Guides

      In-depth engineering articles explaining 1P aerosol generators, volume sizing, and comparisons against gas and dry powder systems.

      07 · Technical & Sourcing FAQ

      DIN Rail Aerosol Fire Extinguisher Selection & Safety Questions

      Prinsip Kerja How does a 1P DIN rail aerosol fire extinguisher activate without external power?

      VIOX QRR Mini DIN rail aerosol extinguishers use an integrated thermal detection cord calibrated to ~170°C. When an electrical arc or overheated breaker raises the internal cabinet temperature to the trigger threshold, the thermal cord automatically ignites the solid potassium-based aerosol compound—releasing an ultra-fine fire-suppressing cloud within seconds, requiring zero electricity, batteries, or external sensors.

      Volume Sizing What enclosure volume do 10g, 20g, and 30g VIOX QRR aerosol extinguishers protect?

      Per VIOX factory ratings for enclosed electrical cabinets, a 10g unit (QRR-0.01G) protects up to 0.4 m³, a 20g unit protects up to 0.8 m³, and a 30g unit (QRR-0.03G) protects up to 1.2 m³. For larger switchgear bays or BESS racks exceeding 1.2 m³, install multiple synchronized units or specify our Smart Wireless / RS485 multi-zone series.

      Electronics Safety Will condensed aerosol discharge damage PLCs, MCBs, or cause short circuits?

      No. Condensed aerosol extinguishing particles are electrically non-conductive, non-corrosive, and leave virtually zero wet residue—unlike water sprinklers or messy ABC dry chemical powder that corrode PCBs and relays. After extinguishing an incipient electrical fire, the cabinet can be ventilated and inspected immediately.

      Instalasi How much DIN rail space is needed and where should I mount the unit?

      The QRR-0.01G / QRR-0.01G/S mini series measures just 84.5 × 18 × 60 mm—occupying exactly 1 module (1P) on a standard 35 mm DIN rail right next to MCBs, RCBOs, and SPDs. It also supports 3M magnetic or screw mounting. Position the unit near the upper half of the enclosure with the discharge nozzle unobstructed.

      Kehidupan Pelayanan Does a DIN rail aerosol fire extinguisher require annual pressure inspections?

      No. Because the extinguishing agent is stored as a stable solid compound inside a non-pressurized housing, there is zero risk of gas leakage and no pressurized cylinder testing required. VIOX QRR units provide up to 10 years of maintenance-free standby protection.

      Smart BMS / RS485 Can VIOX aerosol extinguishers send a fire alarm signal to our BMS or SCADA system?

      Yes. Our Smart Wireless and RS485 (Modbus RTU) series provide real-time fire feedback dry contacts, integrated sound-and-light local alarms, and cloud/BMS telemetry so facility operators are alerted the instant a cabinet fire is suppressed.

      Direct Engineering & OEM Fire Safety Support

      Need DIN Rail Aerosol Extinguisher Samples, MSDS or OEM Pricing?

      Share your cabinet dimensions, target quantity, and whether you need standalone thermal units or RS485 BMS telemetry. VIOX factory engineers reply with datasheets, test reports, and tiered pricing within 24 hours.

      1P 18 mm DIN-Rail & 3M Magnetic 10-Year Maintenance-Free Standby OEM Logo & Custom Cord Ready