VIOX ELECTRIC
Langue

VIOX VSP-RT Series Built-In Replaceable Fuse SPD (VSP-X15RT/B+C · VSP-20RT · VSP-80RT / 100RT)

The VIOX VSP-RT series (VSP-X15RT/B+C Type 1+2 12.5 kA, VSP-20RT Type 2 40 kA, and VSP-80RT / VSP-100RT Type 2 80–100 kA) integrates both a thermal disconnector and an internal replaceable overcurrent fuse directly inside each pluggable SPD module. Purpose-built for rail transit signaling, unmanned telecom shelters, and critical industrial power cabinets requiring dual-layer fail-safe protection.

Série VIOX
VSP-X15RT / VSP-20RT / VSP-80RT / VSP-100RT
Tension nominale
AC 275V / 320V / 385V / 440V
Surge Rating
T1+2 12.5kA · T2 40kA / 80kA / 100kA
Standard
IEC 61643-11 · Built-In Replaceable Fuse

Vue d'ensemble

The VIOX VSP-RT series (VSP-X15RT/B+C Type 1+2 12.5 kA, VSP-20RT Type 2 40 kA, and VSP-80RT / VSP-100RT Type 2 80–100 kA) integrates both a thermal disconnector and an internal replaceable overcurrent fuse directly inside each pluggable SPD module. Purpose-built for rail transit signaling, unmanned telecom shelters, and critical industrial power cabinets requiring dual-layer fail-safe protection.

Caractéristiques

  • Dual-protection fail-safe design: internal thermal disconnector PLUS replaceable integrated overcurrent fuse inside every module.
  • Three performance tiers: VSP-X15RT/B+C (Type 1+2, Iimp 12.5 kA / Imax 40 kA), VSP-20RT (Type 2, In 20 / Imax 40 kA), and VSP-80RT / 100RT (Type 2, Imax 80 / 100 kA).
  • High-energy MOV + GDT series architecture delivers zero standby leakage current and zero follow current.
  • Dedicated visual fault indicator + optional 11/12/14 remote signaling across 1P–4P DIN-rail housings.

Spécifications

VSP-X15RT / VSP-20RT / VSP-80RT / VSP-100RT Electrical & Mechanical Specifications

ParamètreSpécification
Series LineupVSP-X15RT/B+C (T1+T2) · VSP-20RT (T2) · VSP-80RT / VSP-100RT (T2 Heavy)
Max Continuous Operating Voltage (Uc)275 V / 320 V / 385 V / 440 V AC
Surge Discharge RatingsX15RT: Iimp 12.5 kA, Imax 40 kA · 20RT: In 20 / Imax 40 kA · 80RT/100RT: Imax 80 / 100 kA
Niveau de protection de tension (Up)X15RT: 2.0 kV · 20RT: 1.2–1.8 kV · 80RT: 1.8 kV · 100RT: 2.0 kV
Integrated DisconnectionInternal thermal disconnector + internal replaceable overcurrent fuse
Response Time & Leakage<25 ns · Residual Leakage Current (Ipe): NONE · Isccr: 25,000 A
Terminals & Environment6–35 mm² (2.0–2.5 N·m) · PBT/PA UL94 V-0 · IP20 · -40°C to +70°C

VSP-X15RT / VSP-20RT / VSP-80RT / VSP-100RT Available Poles & Dimensions

Model Tier1P2P3P4P
VSP-X15RT/B+C & VSP-20RT18 × 90 × 67 mm36 × 90 × 67 mm54 × 90 × 67 mm72 × 90 × 67 mm
VSP-80RT / VSP-100RT36 × 90(83) × 70.5 mm72 × 90(83) × 70.5 mm108 × 90(83) × 70.5 mm144 × 90(83) × 70.5 mm

Dimensions et Installation

VIOX VSP-RT Series Built-In Replaceable Fuse SPD (VSP-X15RT/B+C · VSP-20RT · VSP-80RT / 100RT) Dimensional Drawing (mm)
VSP-X15RT / VSP-20RT / VSP-80RT / VSP-100RT Outline & DIN-Rail Mounting Dimensions (unit: mm)
  • Engineered for rail transit traction/signaling cabinets and unmanned remote power cabinets where built-in replaceable fusing simplifies maintenance.
  • Replace only with matched VIOX VSP-RT plug-in modules or factory-rated fuse inserts.
  • Explore the complete VIOX Surge Protection Devices (SPD) catalog for matched AC, Solar PV DC, and SCB backup protection.

FAQ

What makes the VSP-RT series different from standard pluggable SPDs?

Each VSP-RT module houses both a thermal disconnector and a replaceable overcurrent fuse internally, eliminating fire risk from short-circuit MOV failures in unmanned rail transit and industrial power cabinets.

Besoin d'un devis produit ?
Construisons-le ensemble.

Envoyez-nous le modèle du produit, les caractéristiques techniques, la quantité et les exigences OEM. Notre équipe examinera votre demande et vous répondra dans un délai d'un jour ouvré.

Demander un Devis