VIOX VSP-RT Series Built-In Replaceable Fuse SPD (VSP-X15RT/B+C · VSP-20RT · VSP-80RT / 100RT)

The VIOX VSP-RT series (VSP-X15RT/B+C Type 1+2 12.5 kA, VSP-20RT Type 2 40 kA, and VSP-80RT / VSP-100RT Type 2 80–100 kA) integrates both a thermal disconnector and an internal replaceable overcurrent fuse directly inside each pluggable SPD module. Purpose-built for rail transit signaling, unmanned telecom shelters, and critical industrial power cabinets requiring dual-layer fail-safe protection.

VIOX Series
VSP-X15RT / VSP-20RT / VSP-80RT / VSP-100RT
แรงดันไฟฟ้าพิกัด
AC 275V / 320V / 385V / 440V
Surge Rating
T1+2 12.5kA · T2 40kA / 80kA / 100kA
มาตรฐาน
IEC 61643-11 · Built-In Replaceable Fuse

ภาพรวม

The VIOX VSP-RT series (VSP-X15RT/B+C Type 1+2 12.5 kA, VSP-20RT Type 2 40 kA, and VSP-80RT / VSP-100RT Type 2 80–100 kA) integrates both a thermal disconnector and an internal replaceable overcurrent fuse directly inside each pluggable SPD module. Purpose-built for rail transit signaling, unmanned telecom shelters, and critical industrial power cabinets requiring dual-layer fail-safe protection.

คุณสมบัติ

  • Dual-protection fail-safe design: internal thermal disconnector PLUS replaceable integrated overcurrent fuse inside every module.
  • Three performance tiers: VSP-X15RT/B+C (Type 1+2, Iimp 12.5 kA / Imax 40 kA), VSP-20RT (Type 2, In 20 / Imax 40 kA), and VSP-80RT / 100RT (Type 2, Imax 80 / 100 kA).
  • High-energy MOV + GDT series architecture delivers zero standby leakage current and zero follow current.
  • Dedicated visual fault indicator + optional 11/12/14 remote signaling across 1P–4P DIN-rail housings.

ข้อมูลจำเพาะ

VSP-X15RT / VSP-20RT / VSP-80RT / VSP-100RT Electrical & Mechanical Specifications

พารามิเตอร์ข้อมูลจำเพาะ
Series LineupVSP-X15RT/B+C (T1+T2) · VSP-20RT (T2) · VSP-80RT / VSP-100RT (T2 Heavy)
Max Continuous Operating Voltage (Uc)275 V / 320 V / 385 V / 440 V AC
Surge Discharge RatingsX15RT: Iimp 12.5 kA, Imax 40 kA · 20RT: In 20 / Imax 40 kA · 80RT/100RT: Imax 80 / 100 kA
ระดับการป้องกันแรงดันไฟฟ้า (Up)X15RT: 2.0 kV · 20RT: 1.2–1.8 kV · 80RT: 1.8 kV · 100RT: 2.0 kV
Integrated DisconnectionInternal thermal disconnector + internal replaceable overcurrent fuse
Response Time & Leakage<25 ns · Residual Leakage Current (Ipe): NONE · Isccr: 25,000 A
Terminals & Environment6–35 mm² (2.0–2.5 N·m) · PBT/PA UL94 V-0 · IP20 · -40°C to +70°C

VSP-X15RT / VSP-20RT / VSP-80RT / VSP-100RT Available Poles & Dimensions

Model Tier1พ2พี3พี4P
VSP-X15RT/B+C & VSP-20RT18 × 90 × 67 mm36 × 90 × 67 mm54 × 90 × 67 mm72 × 90 × 67 mm
VSP-80RT / VSP-100RT36 × 90(83) × 70.5 mm72 × 90(83) × 70.5 mm108 × 90(83) × 70.5 mm144 × 90(83) × 70.5 mm

ขนาดและการติดตั้ง

VIOX VSP-RT Series Built-In Replaceable Fuse SPD (VSP-X15RT/B+C · VSP-20RT · VSP-80RT / 100RT) Dimensional Drawing (mm)
VSP-X15RT / VSP-20RT / VSP-80RT / VSP-100RT Outline & DIN-Rail Mounting Dimensions (unit: mm)
  • Engineered for rail transit traction/signaling cabinets and unmanned remote power cabinets where built-in replaceable fusing simplifies maintenance.
  • Replace only with matched VIOX VSP-RT plug-in modules or factory-rated fuse inserts.
  • Explore the complete VIOX Surge Protection Devices (SPD) catalog for matched AC, Solar PV DC, and SCB backup protection.

คำถามที่พบบ่อย

What makes the VSP-RT series different from standard pluggable SPDs?

Each VSP-RT module houses both a thermal disconnector and a replaceable overcurrent fuse internally, eliminating fire risk from short-circuit MOV failures in unmanned rail transit and industrial power cabinets.

ต้องการใบเสนอราคาสินค้า?
มาร่วมสร้างสรรค์ไปกับเรา.

ส่งรุ่นสินค้า พิกัดทางเทคนิค จำนวน และความต้องการ OEM มาให้เรา ทีมงานของเราจะตรวจสอบการใช้งานของคุณและตอบกลับภายในหนึ่งวันทำการ.

ขอใบเสนอราคา