A Dual Power Automatic Transfer Switch (ATS) is a critical electrical device that automatically switches your power supply between two sources – typically from main grid power to backup generator power. When the primary power source fails, our ATS ensures seamless, instantaneous transfer to your backup power source, guaranteeing continuous operation of your critical systems.

Why Choose VIOX Electric as Your Dual Power Automatic Transfer Switch Manufacturer?

VIOX Electric operates as a professional Dual Power Automatic Transfer Switch manufacturer with ISO 9001:2015-certified facilities where every ATS undergoes rigorous quality validation. Our commitment to excellence has made us a trusted partner for electrical contractors, power system integrators, and OEM manufacturers worldwide.

Commutateur de transfert automatique à double alimentation
  • Industry-Leading Testing: Every VIOX ATS undergoes rigorous 100% testing against international safety standards
  • Superior Quality Materials: Premium-grade components ensure longer lifespan and reliable performance
  • Engineering Innovation: Our R&D team continually enhances ATS technology for improved power transfer reliability
  • Global Certification: IEC, CE, UL, CCC, CB, TUV, and SAA certifications across our entire ATS range
  • Soutien global : From selection guidance to installation training and after-sales service
  •  

Environmental & Operating Conditions (All Series)

ParamètresConditions standardConditions extrêmes
Température ambianteDe -5°C à +40°C-25°C to +70°C (storage)
Humidité relative≤50% at +40°C≤90% at +20°C
Altitude≤2000mUp to 4000m (with derating)
Degré de pollutionGrade 3Indoor installation
Niveau de protectionIP30 (standard)IP20-IP40 (depending on model)
Résistance aux vibrationsClass M1Shock resistant design
Installation CategoryCategory IIIFixed installation only

Complete VIOX Electric ATS Model Range

Série de modèlesPlage de courant (A)Tension nominaleType d'applicationCaractéristiques principales
VOQ3-43 Series32 – 630AAC400VHigh Current IndustrialBuilt-in controller, Fast switching, ATS integration
VOQ3 Series20 – 1600AAC400VHeavy IndustrialHigh capacity, Multiple configurations
VOQ3-46 Series125 – 630AAC400VCommercial/IndustrielCompact design, Reliable performance
Série VOQ4-100E16 – 100AAC400VCommercial/Industriel légerDirect load type, PC class, Ultra-fast switching
VOQ4-100R Series16 – 100AAC400VApplications commercialesModular design, Easy maintenance
VOQ4-80AE Series10 – 80AAC220V/690VRésidentiel/Petit commerceElectronic control, LCD display
VOQ4-63AE Series10 – 63AAC220V/690VRésidentiel/Petit commerceCompact frame, Advanced protection
VOQ2-63 Series10 – 63AAC220VRésidentiel/Commercial légerCircuit breaker type, Cost-effective
Paramètres32A63A100A250A400A630A1600A
Tension nominale (Ue)AC400V
Tension d'isolation nominale (Ui)750V1000V
Rated Impulse Voltage (Uimp)8 kV12kV
Conventional Thermal Current (Ith)32A63A100A250A400A630A1600A
Operating Torque12 N⋅m19 N⋅m26 N⋅m39 N⋅m50 N⋅m50 N⋅m70 N⋅m
Durée de vie mécanique10,000 ops5,500 ops4,000 ops
Weight (kg)7.288.214151732
Switching Time≤50ms
ModèleVOQ4-100EVOQ4-100RVOQ4-80AEVOQ4-63AE
Plage de courant nominal16-100A16-100A10-80A10-63A
Tension nominaleCA 400 V, 50 HzCA 400 V, 50 HzAC220V/690VAC220V/690V
Tension d'impulsion nominale8 kV8 kV8 kV
ClassificationPC classPC classAC-31BAC-31B
Numéro du poteau2, 3, 42, 3, 42P, 3P, 4PFrame: 63
Switching Time8ms≤50ms20ms20ms
Durée de vie mécanique≥6,000≥6,000≥6,000≥6,000
Durée de vie électrique≥1,500≥1,500≥1,500
Fréquence nominale50Hz50Hz50/60Hz50/60Hz
Caractéristiques spécialesDirect load typeController wiringElectronic controlConception compacte
ParamètresSpécifications
Plage de courant nominal10A, 16A, 20A, 25A, 32A, 40A, 50A, 63A
Tension nominaleAC220V
Type2P (C type), CT type, D type, F type, Z type
Frame Size Current10-63A
ClassificationCircuit breaker type
Numéro du poteau2, 3, 4
StandardGB/T14048.11-2008
ATSE ClassCB class, with overload and short-circuit protection
Caractéristiques de protectionOverload protection, Short-circuit protection
Température de fonctionnementDe -5°C à +40°C
InstallationMontage sur rail DIN

VIOX ATS WORKSHOP

Obtenez votre ATS Sample

Nous fournissons des échantillons, il vous suffit de nous dire ce dont vous avez besoin

More Than Just a ATS Manufacturer

Chez VIOX, nous allons au-delà de la fabrication Dual Power Automatic Transfer Switches by offering a suite of value-added services tailored to meet your project needs. Our commitment to excellence ensures that every customer receives personalized attention, expert guidance, and seamless support throughout their ATS implementation journey.

Consultation sur les services

Consultation sur les services

Whether your Dual Power Automatic Transfer Switch requirements are straightforward or complex, our team provides expert advice and technical consultation. For more intricate projects, we offer in-depth engineering support to ensure optimal ATS selection and application, guaranteeing safety and efficiency in your power transfer systems.

Commutateur de transfert automatique à double alimentation 03

Recommandations sur les produits

Unsure which Dual Power Automatic Transfer Switch suits your system? Our specialists provide free, customized recommendations based on your specific operational and environmental requirements, ensuring you get the perfect ATS solution for your power management needs.

Soutien logistique

Soutien logistique

If you lack a reliable freight forwarder, we can arrange transportation of your Dual Power Automatic Transfer Switch orders from our factory to your project site at no extra cost. Our logistics team ensures timely and secure delivery to keep your project on schedule.

ATS dans le panneau

Aide à l'installation

Need help with Dual Power Automatic Transfer Switch installation? Our technical team is available to answer your questions or provide hands-on support. For larger projects, we can dispatch an engineer to your site for on-the-ground ATS installation assistance.

Everything About Dual Power Automatic Transfer Switches

What is a Dual Power Automatic Transfer Switch?

A Dual Power Automatic Transfer Switch (ATS) is a vital electrical safety device designed to automatically transfer electrical loads between two power sources. It functions by continuously monitoring the primary power source and instantly switching to a backup source when power quality falls below acceptable parameters or when a complete outage occurs.

Dual Power Automatic Transfer Switches are essential components in modern electrical systems, protecting critical operations from power interruptions caused by utility outages, equipment failures, and maintenance activities. As electrical systems become more sophisticated and dependent on continuous power, the importance of reliable ATS solutions continues to grow.

Types de commutateurs de transfert automatique à double alimentation

Understanding the different types of Dual Power Automatic Transfer Switches is crucial for selecting the right power transfer solution:

  • Open Transition ATS: Brief interruption during transfer, cost-effective for non-critical loads
  • Closed Transition ATS: Momentary parallel operation of sources, ideal for sensitive equipment
  • Soft Loading ATS: Gradual load transfer to minimize electrical stress
  • Fast Transfer ATS: Millisecond switching for critical applications
  • Static Transfer Switch: Solid-state switching with no mechanical parts
  • Bypass Isolation ATS: Manual bypass capability for maintenance

How Dual Power Automatic Transfer Switches Work

The fundamental principle behind Commutateur de transfert automatique à double alimentation operation is continuous power monitoring and automatic source switching:

Monitoring Phase: The ATS continuously monitors voltage, frequency, and phase sequence of the primary power source. Advanced units monitor multiple parameters including voltage variations, frequency deviations, and phase rotation.

Detection Response: When power quality falls outside acceptable parameters, the ATS initiates the transfer sequence. This includes delays to prevent unnecessary switching due to brief disturbances.

Source Switching: The transfer switch automatically connects loads to the backup power source, ensuring continuous power supply to critical equipment.

Automatic Retransfer: Once primary power is restored and stabilized, the ATS automatically transfers loads back to the primary source after appropriate time delays.

Key Technical Parameters for Dual Power Automatic Transfer Switches

Understanding these critical specifications is essential for proper ATS selection:

Rated Current (Ie): The rated current ranges from 16 to 3200A depending on the application and switch series

Rated Voltage (Ue): Operating voltage typically ranges from 220V to 690V, with some models supporting AC400V and others AC220V/690V systems

Switching Time (ts): With a switching speed measured in milliseconds, ATSE is essential for environments that cannot tolerate power interruptions

Withstand Closing Current Rating (WCR): When applying a transfer switch consideration must be given to the withstand closing current rating to ensure system integrity and reliability

Tension de commande : Typically AC220V or DC24V for control circuit operation

Environmental Ratings: Operating temperature ranges typically from -25°C to +70°C with protection levels from IP20 to IP40

Dual Power Automatic Transfer Switch Selection Guide

When selecting the right Commutateur de transfert automatique à double alimentation, consider these critical factors:

Load Analysis: Different loads have varying power requirements. Motor loads have high starting currents, necessitating a higher capacity ATS

Transfer Time Requirements: The required transfer time varies depending on the application. Data centers require millisecond-level switching, while less critical loads can tolerate slightly longer transfer times

Application Type: Generally choose PC-level ATS for applications where power outages are not allowed and in particularly important power consumption occasions such as communication centers, banking and securities industries, hospitals, and airports

Mode de fonctionnement : Choose between self-injection and self-recovery (automatic return to normal power), self-injection but no self-recovery, or mutual backup operation modes

Conditions environnementales : Consider operating temperature, humidity, installation location, and protection level requirements

Conformité aux normes : Ensure compliance with relevant standards such as IEC60947-3, IEC60947-6, GB14048.3, and GB14048.11

Dual Power Automatic Transfer Switch Installation Best Practices

Proper installation is crucial for effective Commutateur de transfert automatique à double alimentation performance:

Sélection de l'emplacement : Install ATS in accessible location with adequate ventilation and protection from environmental hazards.

Source Coordination: Ensure proper coordination between utility supply, ATS, and backup generator systems.

Mise à la terre : Establish solid grounding connections according to local electrical codes and manufacturer specifications.

Control Wiring: Use appropriate control cables and maintain separation from power conductors to prevent interference.

Essais et mise en service : Perform comprehensive testing of all ATS functions before placing the system in service.

Dual Power Automatic Transfer Switch Maintenance and Testing

Un entretien régulier garantit des performances optimales du SPD :

Inspection visuelle : Vérifiez mensuellement l'absence de dommages physiques, de corrosion ou de connexions desserrées. Recherchez également les signes de contrainte thermique ou de détérioration.

Indicateurs d'état : Moniteur SPD Indicateurs d'état (généralement vert pour normal, rouge pour défaut). Remplacez immédiatement les appareils défectueux.

Essais électriques : Effectuer des tests électriques annuels pour vérifier SPD fonctionnalités et les niveaux de protection. Utiliser un équipement de test approprié conçu pour SPD essai.

Documentation: Tenir des registres de SPD installation, test et remplacement pour suivre les performances du système et planifier la maintenance.

Critères de remplacement : Remplacer DOCUP qui présentent des signes de dommages, échouent aux tests ou atteignent la fin de leur durée de vie spécifiée par le fabricant.

Dual Power Automatic Transfer Switch Maintenance and Testing

Regular maintenance ensures optimal ATS performance and involves a combination of regularly scheduled tests, visual inspections, and routine cleaning:

NFPA 110 Requirements: Transfer switches shall be subjected to a maintenance and testing program that includes inspection of connections, contact inspection and cleaning, mechanical and electrical operation tests, and replacement of contacts when required

Calendrier d'entretien : It is strongly recommended that scheduled comprehensive reviews are performed by a qualified technician quarterly with internal maintenance performed once a year

Liste de contrôle d'inspection visuelle : Check for loose or damaged wires, inspect contactors and relays for signs of wear, verify all connections are tight and secure, and look for evidence of overheating such as discolored insulation

Tests fonctionnels : Monitor automatic transfer switch operation and listen for any unusual noises that could indicate a problem. Conduct insulation resistance tests as required

Documentation: Maintain detailed records of all tests and maintenance tasks performed on the ATS, including thermal imaging reports and problem resolution activities

Exigences de sécurité : NFPA 99 and 110 specifically state maintenance and testing activities will be performed by qualified/competent personnel

Dual Power Automatic Transfer Switch Applications and Industries

Dual Power Automatic Transfer Switches are essential across numerous critical applications:

Healthcare Facilities: Essential for environments that cannot tolerate power interruptions, such as hospitals where life-safety and critical medical equipment depend on continuous power

Centres de données : Critical for data centers, communication stations, and server applications where data centers often have multiple power sources including utility grid, generators, and UPS systems

Fabrication industrielle : Essential for industrial production lines where power interruptions can cause costly downtime and equipment damage

Bâtiments commerciaux : Applied in power distribution and protection for residential, commercial, and industrial buildings

Emergency Services: Critical for fire protection systems where loads such as fire pumps, fire fans, and fire elevators need to ensure reliability of power supply

Systèmes d'énergie renouvelable : Can be used with renewable energy sources such as solar panels or wind turbines when compatible with specific voltage, frequency, and technical specifications

Future of Dual Power Automatic Transfer Switch Technology

Les Commutateur de transfert automatique à double alimentation industry continues to evolve with advancing technology:

Smart ATS Systems: Integration of IoT capabilities allows remote monitoring, predictive maintenance, and system optimization with real-time data analytics

Enhanced Control: Modern systems feature intelligent controllers with computer networking interfaces to realize remote control, remote adjustment, remote signaling, and telemetry functions

Intégration des énergies renouvelables : Next-generation ATS systems accommodate renewable energy sources and can be integrated with solar panels, wind turbines, and battery storage systems

Advanced Monitoring: Modern units feature LCD displays showing battery real-time voltage, working status of utility power, inverter and battery with fast transfer times of ≤10ms

Capacités de personnalisation : Manufacturers now offer customized production according to customers’ special requirements, including specific voltage and current specifications and personalized functional requirements

Always consult with a qualified electrical engineer to ensure the Commutateur de transfert automatique à double alimentation meets your specific power system requirements and local electrical codes. It is highly recommended to have a qualified technician or electrician install your dual power automatic transfer switch to ensure proper installation, sizing, and integration with your existing electrical system.

YUEQING: Dual Power Automatic Transfer Switch Manufacturing Hub

Yueqing, a county-level city in Zhejiang Province, China, is recognized as one of the world’s largest manufacturing hubs for electrical switching devices, including Dual Power Automatic Transfer Switches. Known as the “Electrical Capital of China,” this city in the Wenzhou region has gained prominence due to its extensive network of electrical component manufacturers and advanced ATS production capabilities.

La domination de la ville dans Commutateur de transfert automatique à double alimentation manufacturing is driven by its high concentration of specialized factories, such as VIOX Electric, which focus on producing high-quality electrical transfer switches. Yueqing boasts state-of-the-art ATS manufacturing facilities with automated production lines and strict quality control measures. Its proximity to major transportation hubs ensures efficient global distribution of Commutateur de transfert automatique à double alimentation products. Additionally, the industry emphasizes research and development, offering customized OEM/ODM ATS solutions while adhering to international standards like UL, CE, CSA, IEC, and RoHS certifications.

Request an VIOX ATS Sample

VIOX Electric is ready to assist you with your OEM ATS needs. We offer high-quality and cost-effective solutions.

Demander un devis maintenant