VIOX ELECTRIC
زبان

VIOX VM6LE Series Photovoltaic IoT Reclosing MCCB (160A–1250A, 4P)

VIOX VM6LE Series 4-Pole Photovoltaic IoT Reclosing MCCB (160 A–1250 A, AC 400 V, Class B, up to 65 kA Icu) integrates anti-islanding grid-tie protection, 20–60 s automatic reclosing, stepless electronic overcurrent + 50–1000 mA leakage protection, high-precision metering, and RS485/Modbus/carrier communication.

Frame Range
160–1250 A (6 Frames · 4P)
PV Grid-Tie
Anti-Islanding · 20–60 s Reclosing
Breaking & Icw
50–65 kA Icu · Icw 5–8 kA/1s
Protocols
RS485 · Modbus · Carrier · Metering

نمای کلی

The VIOX VM6LE Series is a 4-pole photovoltaic grid-tie IoT reclosing molded case circuit breaker engineered for distributed commercial/utility solar interconnections. Covering 6 frames from 160 A to 1250 A (40 A–1250 A stepless adjustable, AC 400 V, Ui 1000 V, Uimp 8 kV, Class B), VM6LE provides mandatory anti-islanding disconnection during utility outages, automatic 20–60 s reclosing upon grid restoration, adjustable 50–1000 mA earth-leakage protection, high-precision metering (Code JL), and Modbus/RS485/carrier protocols.

ویژگی‌ها

  • Dedicated solar PV grid-tie anti-islanding protection with 20–60 s automatic reclosing (TD type).
  • 6 frames: VM6LE-160, 250, 400, 630, 800, and 1250 A (4P, stepless electronic current adjustment).
  • Breaking capacity up to 65 kA Icu / 42 kA Ics (400–630 A) and 50 kA Icu / 35 kA Ics (160–250 / 800–1250 A).
  • Integrated electronic earth-leakage protection: 50, 100, 200, 300, 400, 500, 800, and 1000 mA (IΔm 25% Icu).
  • Multiple communication protocols: Modbus (MB1 / MB2 English cost-control), RS485, carrier (Z/GZ), and utility protocols.
  • Optional metering (JL), temperature display (WD), PV function (GF), and cost-control (FK/FKV).

مدل‌ها

Frame SeriesStepless Adjustable In (A)لهستانی‌هاIcu / Ics (400 V)Icw & Dimensions W×L×H (mm)
VM6LE-16040–100 A · 64–160 A4P50 kA / 35 kA5 kA/1s · 120 × 180 × 112
VM6LE-25050–125 A · 100–250 A4P50 kA / 35 kA8 kA/1s · 142 × 240 × 100
VM6LE-400160–400 A4P65 kA / 42 kA8 kA/1s · 198 × 336 × 157
VM6LE-630252–630 A4P65 kA / 42 kA8 kA/1s · 198 × 336 × 157
VM6LE-800320–800 A4P50 kA / 35 kA8 kA/1s · 280 × 275.5 × 169
VM6LE-1250400–1000 A · 500–1250 A4P50 kA / 35 kA8 kA/1s · 280 × 275.5 × 169

مشخصات

Reclosing, Leakage & Insulation Data

پارامترمشخصات
Rated Ue / Ui / UimpAC 400 V / 1000 V / 8 kV
دسته‌بندی انتخابی (Selectivity category)Class B (Icw 5 kA/1s on 160 A; 8 kA/1s on 250–1250 A)
Residual current IΔn50, 100, 200, 300, 400, 500, 800, 1000 mA adjustable (AC type)
Residual breaking IΔm25% Icu
Automatic reclosing time20 s – 60 s (TD type)
پروتکل‌های ارتباطیRS485 Modbus (MB1/MB2), Carrier (Z/GZ), Utility Grid protocols

راهنمای انتخاب

موقعیت کدمعنیCatalog Value or Options
VM6LEسریPhotovoltaic IoT reclosing molded case circuit breaker (4P)
160–1250جریان فریم160, 250, 400, 630, 800, 1250 A
C / S / M / HHousing & breakingC/S = short-body reclosing; M/H = tall-body high breaking
JL / WD / GF / GZ / FKتوابعJL Metering · WD Temp · GF PV · GZ PV Carrier · FK/FKV Cost Control
MB1 / MB2Export protocolsMB1 Modbus RTU · MB2 Modbus English cost-control protocol

1. Meet PV Grid-Tie Rules

Use VM6LE at commercial rooftop PV points of common coupling (PCC) for automatic anti-islanding.

2. Minimize PV Downtime

20–60 s automatic reclosing restores solar export automatically once utility voltage stabilizes.

3. Choose Export Protocol

Specify MB1 or MB2 Modbus protocol for international solar SCADA & EMS integration.

4. Verify Cabinet Length

Check 180–336 mm length on reclosing frames before finalizing PV grid-tie box layouts.

نصب

سوالات متداول

What does anti-islanding protection do on VM6LE?

If the utility grid loses power or goes out of voltage/frequency bounds, VM6LE automatically disconnects the solar PV inverter to protect line workers, then auto-recloses 20–60 seconds after stable grid power returns.

Which communication protocol should international buyers order?

Specify MB1 (standard Modbus RTU) or MB2 (Modbus with English cost-control support) for international SCADA and EMS platforms.

What frame sizes does VM6LE cover?

Six 4-pole frames: 160 A, 250 A, 400 A, 630 A, 800 A, and 1250 A with stepless electronic current adjustment.

Does VM6LE include earth-leakage protection?

Yes. VM6LE integrates adjustable electronic residual-current protection from 50 mA to 1000 mA (IΔm = 25% Icu).

What is the difference between C/S and M/H on VM6LE?

C and S tiers use the compact short-body reclosing housing, while M and H tiers use the tall-body high-breaking housing up to 65 kA Icu.

Can VM6LE measure solar export energy?

Yes. Specify additional function code JL for integrated high-precision electrical metering.

2026 Technical Catalog · Online PDF
VIOX Full 18-Series MCCB & Intelligent Breaker Catalog
Open the complete 18-series catalog online for frame dimensions, time-current trip curves, wiring schematics, and factory order codes (PDF · 26.7 MB).
Open Full Catalog PDF ↗

نیاز به استعلام قیمت محصول دارید؟
بیایید با هم بسازیم.

مدل محصول، مشخصات فنی، تعداد و الزامات OEM خود را برای ما ارسال کنید. تیم ما درخواست شما را بررسی کرده و ظرف یک روز کاری پاسخ خواهد داد.

درخواست قیمت