Tổng quan
The VIOX VM6LE Series is a 4-pole photovoltaic grid-tie IoT reclosing molded case circuit breaker engineered for distributed commercial/utility solar interconnections. Covering 6 frames from 160 A to 1250 A (40 A–1250 A stepless adjustable, AC 400 V, Ui 1000 V, Uimp 8 kV, Class B), VM6LE provides mandatory anti-islanding disconnection during utility outages, automatic 20–60 s reclosing upon grid restoration, adjustable 50–1000 mA earth-leakage protection, high-precision metering (Code JL), and Modbus/RS485/carrier protocols.
Đặc trưng
- Dedicated solar PV grid-tie anti-islanding protection with 20–60 s automatic reclosing (TD type).
- 6 frames: VM6LE-160, 250, 400, 630, 800, and 1250 A (4P, stepless electronic current adjustment).
- Breaking capacity up to 65 kA Icu / 42 kA Ics (400–630 A) and 50 kA Icu / 35 kA Ics (160–250 / 800–1250 A).
- Integrated electronic earth-leakage protection: 50, 100, 200, 300, 400, 500, 800, and 1000 mA (IΔm 25% Icu).
- Multiple communication protocols: Modbus (MB1 / MB2 English cost-control), RS485, carrier (Z/GZ), and utility protocols.
- Optional metering (JL), temperature display (WD), PV function (GF), and cost-control (FK/FKV).
Mô hình
| Frame Series | Stepless Adjustable In (A) | Cực | Icu / Ics (400 V) | Icw & Dimensions W×L×H (mm) |
|---|---|---|---|---|
| VM6LE-160 | 40–100 A · 64–160 A | 4 P | 50 kA / 35 kA | 5 kA/1s · 120 × 180 × 112 |
| VM6LE-250 | 50–125 A · 100–250 A | 4 P | 50 kA / 35 kA | 8 kA/1s · 142 × 240 × 100 |
| VM6LE-400 | 160–400 A | 4 P | 65 kA / 42 kA | 8 kA/1s · 198 × 336 × 157 |
| VM6LE-630 | 252–630 A | 4 P | 65 kA / 42 kA | 8 kA/1s · 198 × 336 × 157 |
| VM6LE-800 | 320–800 A | 4 P | 50 kA / 35 kA | 8 kA/1s · 280 × 275.5 × 169 |
| VM6LE-1250 | 400–1000 A · 500–1250 A | 4 P | 50 kA / 35 kA | 8 kA/1s · 280 × 275.5 × 169 |
Thông số kỹ thuật
Reclosing, Leakage & Insulation Data
| Tham số | Đặc điểm kỹ thuật |
|---|---|
| Rated Ue / Ui / Uimp | AC 400 V / 1000 V / 8 kV |
| Danh mục chọn lọc | Class B (Icw 5 kA/1s on 160 A; 8 kA/1s on 250–1250 A) |
| Residual current IΔn | 50, 100, 200, 300, 400, 500, 800, 1000 mA adjustable (AC type) |
| Residual breaking IΔm | 25% Icu |
| Automatic reclosing time | 20 s – 60 s (TD type) |
| Giao thức giao tiếp | RS485 Modbus (MB1/MB2), Carrier (Z/GZ), Utility Grid protocols |
Hướng dẫn lựa chọn
| Code Position | Ý nghĩa | Catalog Value or Options |
|---|---|---|
| VM6LE | Loạt | Photovoltaic IoT reclosing molded case circuit breaker (4P) |
| 160–1250 | Dòng điện khung | 160, 250, 400, 630, 800, 1250 A |
| C / S / M / H | Housing & breaking | C/S = short-body reclosing; M/H = tall-body high breaking |
| JL / WD / GF / GZ / FK | Chức năng | JL Metering · WD Temp · GF PV · GZ PV Carrier · FK/FKV Cost Control |
| MB1 / MB2 | Export protocols | MB1 Modbus RTU · MB2 Modbus English cost-control protocol |
1. Meet PV Grid-Tie Rules
Use VM6LE at commercial rooftop PV points of common coupling (PCC) for automatic anti-islanding.
2. Minimize PV Downtime
20–60 s automatic reclosing restores solar export automatically once utility voltage stabilizes.
3. Choose Export Protocol
Specify MB1 or MB2 Modbus protocol for international solar SCADA & EMS integration.
4. Verify Cabinet Length
Check 180–336 mm length on reclosing frames before finalizing PV grid-tie box layouts.
Cài đặt
- Observe the front manual-operation lock warning: do not force-invert manual opening/closing during reclosing cycles.
- Specify 4P neutral option A (3P+N conventional) or B/C/D per local utility interconnection code.
- Pair with VIOX AC/DC SPDs và VM7DC 1500 V DC MCCB.
- Explore complete Năng lượng mặt trời & Lưu trữ năng lượng Đừng là một "kẻ côn đồ." Đừng "giết người đưa tin.".
Câu hỏi thường gặp
What does anti-islanding protection do on VM6LE?
If the utility grid loses power or goes out of voltage/frequency bounds, VM6LE automatically disconnects the solar PV inverter to protect line workers, then auto-recloses 20–60 seconds after stable grid power returns.
Which communication protocol should international buyers order?
Specify MB1 (standard Modbus RTU) or MB2 (Modbus with English cost-control support) for international SCADA and EMS platforms.
What frame sizes does VM6LE cover?
Six 4-pole frames: 160 A, 250 A, 400 A, 630 A, 800 A, and 1250 A with stepless electronic current adjustment.
Does VM6LE include earth-leakage protection?
Yes. VM6LE integrates adjustable electronic residual-current protection from 50 mA to 1000 mA (IΔm = 25% Icu).
What is the difference between C/S and M/H on VM6LE?
C and S tiers use the compact short-body reclosing housing, while M and H tiers use the tall-body high-breaking housing up to 65 kA Icu.
Can VM6LE measure solar export energy?
Yes. Specify additional function code JL for integrated high-precision electrical metering.