VIOX ELECTRIC
Ngôn ngữ

VIOX VM6LE Series Photovoltaic IoT Reclosing MCCB (160A–1250A, 4P)

VIOX VM6LE Series 4-Pole Photovoltaic IoT Reclosing MCCB (160 A–1250 A, AC 400 V, Class B, up to 65 kA Icu) integrates anti-islanding grid-tie protection, 20–60 s automatic reclosing, stepless electronic overcurrent + 50–1000 mA leakage protection, high-precision metering, and RS485/Modbus/carrier communication.

Frame Range
160–1250 A (6 Frames · 4P)
PV Grid-Tie
Anti-Islanding · 20–60 s Reclosing
Breaking & Icw
50–65 kA Icu · Icw 5–8 kA/1s
Protocols
RS485 · Modbus · Carrier · Metering

Tổng quan

The VIOX VM6LE Series is a 4-pole photovoltaic grid-tie IoT reclosing molded case circuit breaker engineered for distributed commercial/utility solar interconnections. Covering 6 frames from 160 A to 1250 A (40 A–1250 A stepless adjustable, AC 400 V, Ui 1000 V, Uimp 8 kV, Class B), VM6LE provides mandatory anti-islanding disconnection during utility outages, automatic 20–60 s reclosing upon grid restoration, adjustable 50–1000 mA earth-leakage protection, high-precision metering (Code JL), and Modbus/RS485/carrier protocols.

Đặc trưng

  • Dedicated solar PV grid-tie anti-islanding protection with 20–60 s automatic reclosing (TD type).
  • 6 frames: VM6LE-160, 250, 400, 630, 800, and 1250 A (4P, stepless electronic current adjustment).
  • Breaking capacity up to 65 kA Icu / 42 kA Ics (400–630 A) and 50 kA Icu / 35 kA Ics (160–250 / 800–1250 A).
  • Integrated electronic earth-leakage protection: 50, 100, 200, 300, 400, 500, 800, and 1000 mA (IΔm 25% Icu).
  • Multiple communication protocols: Modbus (MB1 / MB2 English cost-control), RS485, carrier (Z/GZ), and utility protocols.
  • Optional metering (JL), temperature display (WD), PV function (GF), and cost-control (FK/FKV).

Mô hình

Frame SeriesStepless Adjustable In (A)CựcIcu / Ics (400 V)Icw & Dimensions W×L×H (mm)
VM6LE-16040–100 A · 64–160 A4 P50 kA / 35 kA5 kA/1s · 120 × 180 × 112
VM6LE-25050–125 A · 100–250 A4 P50 kA / 35 kA8 kA/1s · 142 × 240 × 100
VM6LE-400160–400 A4 P65 kA / 42 kA8 kA/1s · 198 × 336 × 157
VM6LE-630252–630 A4 P65 kA / 42 kA8 kA/1s · 198 × 336 × 157
VM6LE-800320–800 A4 P50 kA / 35 kA8 kA/1s · 280 × 275.5 × 169
VM6LE-1250400–1000 A · 500–1250 A4 P50 kA / 35 kA8 kA/1s · 280 × 275.5 × 169

Thông số kỹ thuật

Reclosing, Leakage & Insulation Data

Tham sốĐặc điểm kỹ thuật
Rated Ue / Ui / UimpAC 400 V / 1000 V / 8 kV
Danh mục chọn lọcClass B (Icw 5 kA/1s on 160 A; 8 kA/1s on 250–1250 A)
Residual current IΔn50, 100, 200, 300, 400, 500, 800, 1000 mA adjustable (AC type)
Residual breaking IΔm25% Icu
Automatic reclosing time20 s – 60 s (TD type)
Giao thức giao tiếpRS485 Modbus (MB1/MB2), Carrier (Z/GZ), Utility Grid protocols

Hướng dẫn lựa chọn

Code PositionÝ nghĩaCatalog Value or Options
VM6LELoạtPhotovoltaic IoT reclosing molded case circuit breaker (4P)
160–1250Dòng điện khung160, 250, 400, 630, 800, 1250 A
C / S / M / HHousing & breakingC/S = short-body reclosing; M/H = tall-body high breaking
JL / WD / GF / GZ / FKChức năngJL Metering · WD Temp · GF PV · GZ PV Carrier · FK/FKV Cost Control
MB1 / MB2Export protocolsMB1 Modbus RTU · MB2 Modbus English cost-control protocol

1. Meet PV Grid-Tie Rules

Use VM6LE at commercial rooftop PV points of common coupling (PCC) for automatic anti-islanding.

2. Minimize PV Downtime

20–60 s automatic reclosing restores solar export automatically once utility voltage stabilizes.

3. Choose Export Protocol

Specify MB1 or MB2 Modbus protocol for international solar SCADA & EMS integration.

4. Verify Cabinet Length

Check 180–336 mm length on reclosing frames before finalizing PV grid-tie box layouts.

Cài đặt

Câu hỏi thường gặp

What does anti-islanding protection do on VM6LE?

If the utility grid loses power or goes out of voltage/frequency bounds, VM6LE automatically disconnects the solar PV inverter to protect line workers, then auto-recloses 20–60 seconds after stable grid power returns.

Which communication protocol should international buyers order?

Specify MB1 (standard Modbus RTU) or MB2 (Modbus with English cost-control support) for international SCADA and EMS platforms.

What frame sizes does VM6LE cover?

Six 4-pole frames: 160 A, 250 A, 400 A, 630 A, 800 A, and 1250 A with stepless electronic current adjustment.

Does VM6LE include earth-leakage protection?

Yes. VM6LE integrates adjustable electronic residual-current protection from 50 mA to 1000 mA (IΔm = 25% Icu).

What is the difference between C/S and M/H on VM6LE?

C and S tiers use the compact short-body reclosing housing, while M and H tiers use the tall-body high-breaking housing up to 65 kA Icu.

Can VM6LE measure solar export energy?

Yes. Specify additional function code JL for integrated high-precision electrical metering.

2026 Technical Catalog · Online PDF
VIOX Full 18-Series MCCB & Intelligent Breaker Catalog
Open the complete 18-series catalog online for frame dimensions, time-current trip curves, wiring schematics, and factory order codes (PDF · 26.7 MB).
Open Full Catalog PDF ↗

Cần báo giá sản phẩm?
Hãy cùng chúng tôi thực hiện dự án này.

Gửi cho chúng tôi mã sản phẩm, các định mức kỹ thuật, số lượng và yêu cầu OEM. Đội ngũ của chúng tôi sẽ xem xét ứng dụng của bạn và phản hồi trong vòng một ngày làm việc.

Yêu cầu báo giá