The VIOX VOPD3-63VA (63 A) and VOPD3-100VA (100 A) are heavy-duty three-phase DIN-rail voltage and current protectors with simultaneous per-phase L1/L2/L3 digital readouts. Providing 1% full-scale voltage accuracy, fixed phase-loss protection, voltage unbalance monitoring (20–99 V), and full P1/U1–U12/C1–C5 menu programmability, they safeguard 3-phase motors, pumps, compressors, and commercial switchboards.

Model VIOX
VOPD3-63VA / VOPD3-100VA
Napětí
3×220/380 V AC (140–300 V L-N)
Aktuální
63 A / 100 A Adjustable
Formát
91 × 102 × 52 mm (5-Module)

Přehled

The VIOX VOPD3-63VA (63 A) and VOPD3-100VA (100 A) are heavy-duty three-phase DIN-rail voltage and current protectors with simultaneous per-phase L1/L2/L3 digital readouts. Providing 1% full-scale voltage accuracy, fixed phase-loss protection, voltage unbalance monitoring (20–99 V), and full P1/U1–U12/C1–C5 menu programmability, they safeguard 3-phase motors, pumps, compressors, and commercial switchboards.

Funkce

  • Supports both 3×220 V + N (3P+N) and 3×380 V (3P without N) three-phase distribution architectures.
  • Full three-phase protection: over-voltage (U1), under-voltage (U5), over-current (C1: 1–63 A / 1–100 A), phase unbalance (U10: 20–99 V), and fixed phase-loss protection.
  • 1% full-scale voltage measurement accuracy with independent ±9.5% three-phase voltage (U9) and current (C4) calibration.
  • Rated insulation voltage Ui 450 V, IP20 enclosure, Pollution Degree 3, 100,000 electrical & mechanical operations.
  • Automatic recovery after configurable delay (1–500 s) with continuous over-current lockout option (C5).

Specifikace

VOPD3-63VA / VOPD3-100VA Technical Specifications

ParametrSpecifikace
Rated Supply Voltage3×220 V (3P+N) or 3×380 V (3P) · Operating AC 140–300 V L-N, 50/60 Hz
Možnosti jmenovitého prouduVOPD3-63VA: 0.5–63 A · VOPD3-100VA: 1–100 A (default 30 A)
Over-Voltage / Hysteresis230–300 V (default 270 V) · Recovery 225–295 V (default 265 V) · 5 V hysteresis
Under-Voltage / Hysteresis140–210 V (default 170 V) · Recovery 145–215 V (default 175 V) · 3 V hysteresis
Phase Unbalance & Phase LossUnbalance 20–99 V (10 s trip delay) · Phase-Loss Protection permanently ON
Measurement Accuracy & Ui1% full-scale voltage accuracy · Ui 450 V
Life & Environment100,000 electrical & mechanical cycles · IP20 · -5°C to +40°C · ≤2000 m
Rozměry91 (W) × 102 (H) × 52 (D) mm · 35 mm DIN rail

VOPD3-63VA / VOPD3-100VA Programmable Menu Parameters

KódParametrRozsahFactory Default
P1Power-On Delay1–500 s10 s
U1 / U2Over-Voltage Trip / Recovery230–300 V / 225–295 V270 V / 265 V
U3 / U4Over-Voltage Recovery Delay / Action Time1–500 s / 0.1–30 s30 s / 1.0 s
U5 / U6Under-Voltage Trip / Recovery140–210 V / 145–215 V170 V / 175 V
U7 / U8Under-Voltage Recovery Delay / Action Time1–500 s / 0.1–30 s30 s / 1.0 s
U93-Phase Voltage Calibration-9.5% to +9.5%0%
U10 / U11 / U12Voltage Unbalance Trip / Recovery / Enable20–99 V / 5–94 V / ON–OFF20 V / 20 V / OFF
C1 / C2 / C3Over-Current Trip / Recovery Delay / Action Time0.5–63 A (or 1–100 A) / 1–500 s / 0.1–30 s30 A / 30 s / 1.0 s
C4 / C53-Phase Current Calibration / Continuous Lockout-9.5% to +9.5% / OFF, 1–200% / OFF

Wiring & Setup Guide

  • IMPORTANT — Bottom-IN, Top-OUT wiring: connect incoming supply cables to the bottom IN terminals and load cables to the top OUT terminals (reverse of single-phase top-entry models).
  • Maintain strict phase matching (L1–L1, L2–L2, L3–L3, N–N). For 3P 380 V systems without neutral, connect L1/L2/L3 only.
  • Install inside a ventilated distribution panel on a 35 mm DIN rail by a qualified electrician with upstream isolation.
  • Explore the complete VIOX Voltage Protectors catalog for matched DIN-rail switchgear.

ČASTO KLADENÉ DOTAZY

Why does VOPD3-63VA/100VA wire Bottom-IN and Top-OUT?

Unlike single-phase VOPD1 models (top-entry), the 3-phase VOPD3-VA terminal layout feeds incoming 3P+N supply into the bottom IN terminals and exits to the load from the top OUT terminals. Always verify terminal labels on the housing before energizing.

Does VOPD3-63VA protect against phase loss?

Yes. Phase-loss protection is permanently enabled (ON), and voltage unbalance protection (U10–U12) can be configured between 20 V and 99 V.

Potřebujete cenovou nabídku produktu?
Pojďme to vybudovat společně.

Zašlete nám model produktu, technické parametry, množství a požadavky OEM. Náš tým vaši žádost posoudí a odpoví do jednoho pracovního dne.

Požádat o cenovou Nabídku