VIOX ELECTRIC
اللغة

VIOX HR17 690VAC 250A Horizontal 3P Fuse Switch Disconnector

HR17 250A 3P VIOX YR:HR17-690VAC 250A Horizontal 3P Fuse Switch Disconnector is suitable for short circuit protection and overload protection of cable and power equipment of the distribution system. In the case of a short circuit, the current can be broken by the fuse link inside.

سلسلة VIOX
HR17
الجهد المقنن
690VAC
التيار المقنن
250 أمبير
قياسي
IEC 60269

نظرة عامة

HR17 250A 3P VIOX YR:HR17-690VAC 250A Horizontal 3P Fuse Switch Disconnector is suitable for short circuit protection and overload protection of cable and power equipment of the distribution system. In the case of a short circuit, the current can be broken by the fuse link inside. With the features of high isolating function and high durability, YR:HR17-250/3 Horizontal Fuse switch disconnector can withstand high short circuits.

690VAC 250A Horizontal 3P Fuse Switch Disconnector

الميزات

  • IEC60947-3
  • Rated voltage 690VAC and current capacity 250A for hrc fuse switch disconnector applications.
  • High interrupting performance (High Breaking Capacity) with rapid current-limiting fault clearing.
  • Engineered and tested in accordance with IEC 60269 standards.
  • Precision-engineered low-power-loss silver-plated contacts and high-temperature ceramic or flame-retardant housing.
  • Direct OEM replacement geometry for standardized industrial, solar PV, ESS, and EV protection panels.

المواصفات

HR17 Technical Specifications

Model / Size الجهد المقنن (فولت) التيار المقدر (أمبير) Power Frequency Withstand Voltage (V) Recommended Fuse Link Model/Size البُعد الكلي
A E H H1 B
YR:HR17-250/3 690V 250 أمبير 3000V NT1,NH1 240 184 115 290 114

Selection & Installation Notes

  • Verify system maximum voltage (690VAC) and prospective short-circuit fault current before selecting the fuse link or holder rating.
  • Apply ambient-temperature derating when operating inside sealed outdoor combiner boxes or high-density inverter cabinets above 40°C.
  • Always de-energize circuits before replacing cylindrical, blade, or bolted fuse links, and use insulated fuse pullers for NH/NT types.
  • Explore the complete VIOX Fuse & Fuse Holder catalog for matched holders, bases, and disconnectors.

الأسئلة الشائعة

What voltage and current ratings does the VIOX HR17 690VAC 250A Horizontal 3P Fuse Switch Disconnector support?

This VIOX HR17 series is rated for 690VAC with a current rating of 250A and High Breaking Capacity breaking performance. Refer to the technical specification table above for individual part numbers and ampere steps.

Which international standards apply to VIOX HR17 690VAC 250A Horizontal 3P Fuse Switch Disconnector?

The HR17 series is designed and verified to IEC 60269 requirements for safe overcurrent and short-circuit protection.

Where is the VIOX HR17 690VAC 250A Horizontal 3P Fuse Switch Disconnector typically installed?

It is engineered for hrc fuse switch disconnector circuits, protecting cables, busbars, semiconductors, battery modules, or string feeders against thermal overload and high-energy short-circuit faults.

Can VIOX supply matched fuse holders, bases, or OEM private-label packaging?

Yes. VIOX Electric supplies matched DIN-rail fuse holders, NH/NT fuse bases, disconnectors, and OEM/ODM bulk packaging with technical datasheets upon RFQ.

هل تحتاج إلى عرض سعر للمنتج؟
لنبنيها معاً.

أرسل لنا طراز المنتج، والتقييمات الفنية، والكمية، ومتطلبات الشركة المصنعة للمعدات الأصلية (OEM). سيقوم فريقنا بمراجعة طلبك والرد في غضون يوم عمل واحد.

طلب عرض أسعار