Global Electrical Standards Finder
Trace the route from an international IEC product standard to its EN, UL, CSA or GB counterpart—and see the market-access evidence typically required.
IEC · EN · UL · CSA · GB
Build a market pathway
Choose the exact product family before comparing certification systems.
Orientation only. Final requirements depend on ratings, construction, end use, current editions and the responsible authority.
MCB para União Europeia
AC circuit-breakers for household and similar installations, generally up to 125 A. Industrial or higher-voltage applications may instead fall under IEC 60947-2.
-
International foundationIEC 60898-1IEC product standard
-
Target-market standardEN 60898-1EN adoption of IEC
-
Market access routeMarcação CEEU Low Voltage Directive 2014/35/EU; EMC and RoHS legislation may also apply.
Evidence pack to prepare
- Risk assessment
- Relatórios de teste
- Technical construction file
- EU Declaration of Conformity
- Ratings, markings and local-language instructions
One product name can lead to different compliance systems
IEC standards often form the international technical baseline. Europe commonly adopts them as EN standards, China as GB or GB/T standards, while the United States and Canada frequently use a separate UL/CSA framework. Similar function does not mean automatic equivalence.
IEC, EN, UL and GB product crosswalk
Base standard families for orientation. Confirm current editions, amendments and product-specific scope before testing or certification.
| Produto | IEC foundation | European route | United States route | China route |
|---|---|---|---|---|
| MCBDisjuntor miniatura | IEC 60898-1 | EN 60898-1 | UL 489 | GB/T 10963.1 |
| RCCBDisjuntor de Corrente Residual | IEC 61008-1 | EN 61008-1 | UL 943 (GFCI function) | GB/T 16916.1 |
| RCBODisjuntor de Corrente Residual com Proteção contra Sobrecorrente | IEC 61009-1 | EN 61009-1 | UL 489 + UL 943 (GFCI circuit breaker) | GB/T 16917.1 |
| Disjuntor em caixa moldadaMoulded Case Circuit Breaker | IEC 60947-2 | EN 60947-2 | UL 489 | GB/T 14048.2 |
| SPDTipo 1 ou Tipo 2 | IEC 61643-11 | EN 61643-11 | UL 1449 | GB/T 18802.11 |
| PV SPDPhotovoltaic Surge Protective Device | IEC 61643-31 | EN 61643-31 | UL 1449 | GB/T 18802.31 |
| DC MCBDirect Current Miniature Circuit Breaker | IEC 60898-2 / IEC 60947-2 | EN 60898-2 / EN 60947-2 | UL 489 (DC rated) | GB/T 10963.2 / GB/T 14048.2 |
| Isolador DCDC Switch-Disconnector | IEC 60947-3 | EN 60947-3 | UL 98 / UL 98B (PV) | GB/T 14048.3 |
| ContactorElectromechanical Contactor | IEC 60947-4-1 | EN 60947-4-1 | UL 60947-4-1 | GB/T 14048.4 |
| ReléElectromechanical Control Relay | IEC 61810-1 / IEC 60947-5-1 | EN 61810-1 / EN 60947-5-1 | UL 61810-1 / UL 60947-5-1 | GB/T 21711.1 / GB/T 14048.5 |
| Bloco TerminalTerminal Block for Copper Conductors | IEC 60947-7-1 | EN 60947-7-1 | UL 1059 | GB/T 14048.7 |
| Caixa de distribuiçãoDistribution Board / Consumer Unit | IEC 61439-3 + IEC 61439-1 | EN 61439-3 + EN 61439-1 | UL 67 / UL 50E | GB/T 7251.3 + GB/T 7251.1 |
Market-access systems covered
The finder separates national standards from certification and placing-on-market obligations.
União Europeia
EN adoption of IEC
Reino Unido
BS EN adoption
Estados Unidos
ANSI/UL product safety
Canadá
CSA / harmonized UL-CSA
China
GB / GB/T national standards
Austrália / Nova Zelândia
AS/NZS adoption of IEC
Índia
IS / IEC adoption
Brasil
ABNT NBR / IEC adoption
Saudi Arabia
SASO / IEC adoption
United Arab Emirates
UAE.S / IEC adoption
How to use this finder responsibly
A standard number is only the beginning of a compliance decision. The actual route changes with voltage, current, breaking capacity, use category, enclosure, installation system and whether the item is a component or complete assembly.
- Define the product.Fix ratings, construction, intended use and installation environment.
- Confirm the edition.Check current national adoption, amendments, deviations and transition dates.
- Confirm market access.Identify legislation, mandatory certification, local representative and labelling obligations.
- Build the evidence pack.Align test reports, critical components, drawings, risk assessment and production controls.
Standards and certification questions
Is an IEC certificate automatically accepted in every country?
No. IEC provides an international technical foundation, but national adoption, deviations, documentation and certification rules still apply.
Are IEC and UL standards equivalent?
Usually not. They can address similar functions while using different construction rules, ratings, tests, markings and installation assumptions.
Does CE marking mean a notified body certified the product?
Not necessarily. For many low-voltage products, the manufacturer carries out the applicable conformity process, prepares the technical file and declaration, and assumes responsibility for the CE marking.
Why can the application context change the standard?
A household MCB and an industrial circuit breaker may perform a related function but fall under different IEC standard families. DC and photovoltaic applications introduce further rating and switching requirements.
Primary reference authorities
- IEC Webstore — international product standards
- European Commission — Low Voltage Directive
- UL Solutions — product safety and certification
- OSHA — Nationally Recognized Testing Laboratory program
- China National Standards information service
Last editorial review: Agosto 2026. Always verify current official publications and regulations before placing a product on the market.
Planning one product for several markets?
Share the target countries, product ratings and intended application. VIOX can help organize the standard pathway and product configuration before quotation.