VIOX FCT18-ST Start-Delta Timer Relay
The VIOX FCT18-ST Start-Delta Timer Relay is designed for precise control of three-phase motor starting. Features adjustable timing (0.1s – 40min), <0.5% error, 2xSPDT contacts, and DIN rail mounting. Supports AC/DC 12-240V. Reduces inrush current and provides smoother acceleration.
Send your requirements, we will quote for you within 12 hours
- TEL:+8618066396588
- Whatsapp:+8618066396588
- Email:sales@viox.com
Overview
The VIOX FCT18-ST is a specialized start-delta timer relay designed primarily for controlling the starting sequence of three-phase motors. This DIN rail-mounted device provides precise timing control for the star-delta (also known as wye-delta) starting method, which is widely used to reduce inrush current and provide smoother motor acceleration in industrial applications.
Key Features and Benefits
- Specialized Design: Specifically engineered for controlling the delay ON time of motors in star/delta configuration
- Versatile Time Ranges: Adjustable from as quick as 0.1 seconds to as long as 40 minutes
- Wide Power Supply Compatibility: Operates across 12 to 240 VAC/DC power systems
- User-Friendly Setup: Easy configuration with wiring diagrams conveniently located on the side of the product
- Exceptional Precision: Time error less than 0.5% for reliable operation
- Robust Performance: Strong anti-interference capability to ensure stable functioning in noisy electrical environments
Technical Specifications
Model Identification
The model numbering system FCT18-ST 2 W breaks down as follows:
Position | Code | Meaning |
---|---|---|
1. Function | ST | Star-delta relay |
2. Type of output | 2 | 2CO contacts |
3. Supply voltage | W | AC/DC12-240V |
Other supply voltage options include:
- A: AC230V
- D: DC24V
Input and Power Specifications
Parameter | Specification |
---|---|
Input Terminal | A1-A2 |
Voltage range | AC 230V / DC24V / AC/DC 12-240V |
Power consumption | AC 3.5VA / DC 2.0W |
Voltage tolerance | -15% ~ +10% |
Supply indication | Green LED |
Relay indication | Red LED |
Timing Specifications
Parameter | Specification |
---|---|
Time ranges | 0.1s-40min |
Time setting | Via rotary button |
Time deviation | 0.1% |
Repeat accuracy | 0.5% |
Temperature coefficient | 0.05%/°C, at=20°C (0.05%/°F, ≈68°F) |
Output Specifications
Parameter | Specification |
---|---|
Output contact | 2×SPDT (Single Pole Double Throw) |
Rated current | 2×16A |
Mechanical life | 1×107 |
Electrical life | 1×105 |
Environmental and Physical Specifications
Parameter | Specification |
---|---|
Operating temperature | -20 … +60 °C / -40 … +85 °C |
Mounting | DIN rail EN/IEC 60715 |
IP Rating | IP20 |
Stripping length | 7mm (0.28in) |
Installed altitude | ≤2200m |
Pollution level | 2 |
Max cable size | AWG13-20 0.4N·m |
Dimension | 90mm×18mm×64mm |
Weight | about 90g |
Standards | GB/T 14048.5, IEC60947-5-1, EN6812-1 |
How the FCT18-ST Timer Relay Works
Timing Function
The FCT18-ST provides precise timing control for star-delta motor starting with the following sequence:
- When power (Un) is applied to the relay, the timing sequence begins
- The first relay (R1, terminals 11-14) activates immediately, placing the motor in star configuration
- After the preset time T1 elapses, R1 deactivates, creating a brief pause in the motor circuit
- Following this brief pause, the second relay (R2, terminals 21-24) activates, switching the motor to delta configuration for continued operation
Time Setting Options
The FCT18-ST offers 10 different time range settings to accommodate various motor sizes and application requirements:
- 0.1-1s: For very small motors or testing purposes
- 1-10s: Common setting for small to medium motors
- 0.1-1m: For medium-sized motors
- 1-10m: For larger motors requiring gradual acceleration
- 1.5-15m: For specialized applications with extended ramp-up requirements
- 2-20m: For very large motors or high-inertia loads
- 2.5-25m: For heavy-duty industrial applications
- 3-30m: For extreme heavy-duty applications
- 3.5-35m: For specialized industrial processes
- 4-40m: Maximum range for the most demanding applications
Ratio Setting Feature
One of the unique advantages of the FCT18-ST is its adjustable ratio setting, which allows fine-tuning of the timing function. The ratio setting can be adjusted from 10% to 100% in 5% increments, providing precise control over the star-to-delta transition timing. This feature enables optimal motor starting performance across various load conditions.
Applications of FCT18-ST Start-Delta Timer Relay
Industrial Motor Control
The primary application of the FCT18-ST is controlling three-phase motors using the star-delta starting method. This technique is widely used in industrial settings to reduce starting current and provide smoother acceleration for motors typically ranging from 5HP (3.7kW) to 100HP (75kW) and beyond. Common applications include:
- Conveyor systems
- Pumping stations
- HVAC equipment
- Compressors
- Industrial fans and blowers
- Material handling equipment
- Machine tools
- Production line machinery
Benefits of Star-Delta Starting with FCT18-ST
Using the FCT18-ST timer relay for star-delta starting offers numerous advantages:
- Reduced Starting Current: Typically limits inrush current to about 33% of direct-on-line starting
- Minimized Voltage Dips: Prevents power quality issues during motor startup
- Extended Motor Life: Reduced mechanical and thermal stress during starting
- Lower Energy Costs: Efficient starting sequence reduces peak demand charges
- Compliance with Utility Requirements: Meets regulations limiting starting current
- Smoother Acceleration: Gradual application of torque protects connected machinery
Installation and Wiring
Mounting Instructions
The FCT18-ST is designed for easy installation on standard 35mm DIN rails according to EN/IEC 60715. The compact dimensions (90mm×18mm×64mm) make it ideal for installation in control panels with limited space. With an IP20 protection rating, the relay should be installed in appropriate enclosures to protect against dust and moisture.
Wiring Diagram
The FCT18-ST features a straightforward wiring configuration:
- A1: DC+ / AC L (Line)
- A2: DC- / AC N (Neutral)
- Terminals 11-14: First relay output (Star configuration)
- Terminals 21-24: Second relay output (Delta configuration)
For proper operation, connect the power supply to terminals A1-A2, and connect the star and delta contactors to the respective relay outputs. Detailed wiring diagrams are provided on the side of the product for easy reference during installation.
Dimension
Configuration and Operation
Time Range Selection
To set up the FCT18-ST for your specific application:
- Select the appropriate time range using the top rotary dial
- Fine-tune the timing within the selected range using the second rotary dial
- Set the desired ratio using the bottom rotary dial
Operational Indicators
The FCT18-ST includes two LED indicators to provide at-a-glance status information:
- Green LED: Illuminates when power is supplied to the relay
- Red LED: Illuminates when the relay is activated
Troubleshooting and Maintenance
Common Issues and Solutions
Issue | Possible Cause | Solution |
---|---|---|
No LEDs illuminate | No power to the relay | Check power supply connections at A1-A2 |
Timer does not activate outputs | Incorrect time settings | Verify time range and ratio settings |
Erratic operation | Electrical interference | Improve wiring separation, add suppression devices |
Motor fails to start in delta | Incorrect transition timing | Adjust time settings for appropriate motor size |
Maintenance Requirements
The FCT18-ST is designed for long-term reliability with minimal maintenance. With a mechanical life of 10 million operations and an electrical life of 100,000 operations, the relay provides dependable service in demanding industrial environments. Periodic inspection of terminal connections is recommended to ensure secure wiring.
Advantages of VIOX FCT18-ST Over Competitors
Superior Technical Features
- Exceptional Timing Accuracy: With a time error less than 0.5% and a temperature coefficient of just 0.05%/°C, the FCT18-ST provides more precise control than standard timer relays
- Wide Voltage Range: The flexible 12-240 VAC/DC power supply compatibility eliminates the need for multiple relay models in varied installations
- Enhanced EMC Performance: Strong anti-interference capability ensures reliable operation even in electrically noisy industrial environments
Practical Design Advantages
- Intuitive Configuration: Clear markings and accessible controls simplify setup and adjustment
- Compact Size: The space-saving 18mm width design (just one module wide) conserves valuable DIN rail space
- On-Device Documentation: Integrated wiring diagrams eliminate the need for separate installation instructions
Industries and Applications
Key Industry Applications
- Manufacturing: Production machinery, assembly lines, material handling systems
- Water/Wastewater: Pump control for treatment facilities and distribution systems
- HVAC: Air handling units, cooling towers, and large ventilation systems
- Mining: Conveyor systems, crushers, and processing equipment
- Oil & Gas: Pump stations, compressors, and processing equipment
- Food & Beverage: Processing equipment, mixing systems, and packaging machinery
Application Examples
Example 1: Industrial Water Pump
For a 30HP water pump in a municipal water system, the FCT18-ST can be configured with a 5-second timing to provide a smooth transition from star to delta starting. This reduces water hammer effects in the piping system while limiting starting current to protect the electrical infrastructure.
Example 2: Conveyor System
In a mining operation with heavy-duty conveyors, the FCT18-ST can be set with a longer transition time of 10-15 seconds to gradually accelerate the loaded belt, preventing material spillage and reducing mechanical stress on the drive components.
Compliance and Certification
The FCT18-ST complies with international standards including:
- GB/T 14048.5
- IEC60947-5-1
- EN6812-1
These certifications ensure the relay meets stringent requirements for industrial control equipment in terms of performance, safety, and electromagnetic compatibility.
Conclusion
The VIOX FCT18-ST Start-Delta Timer Relay represents a high-quality, versatile solution for motor starting applications across numerous industries. With its precise timing control, robust construction, and user-friendly design, this relay provides reliable performance in demanding industrial environments while extending motor life and reducing electrical stress during startup.
For additional information or to discuss your specific application requirements, please contact our technical support team or request a detailed product datasheet.