VIOX FCT18-AKR Pulse Delayed Timer Relay with Control Signal
The VIOX FCT18-AKR Pulse Delayed Timer Relay provides precise ON-delay timing triggered by a rising edge signal. Features a remarkably wide 0.1s-100 day range, <0.5% error, NPN/PNP control, 1/2 SPDT contacts, DIN rail mount, and universal AC/DC 12-240V power. For demanding industrial applications.
Send your requirements, we will quote for you within 12 hours
- TEL:+8618066396588
- Whatsapp:+8618066396588
- Email:sales@viox.com
Introduction
The VIOX FCT18-AKR is a high-precision pulse delayed timer relay designed for industrial automation systems that require accurate timing control. With its ON-delay (rising edge triggering) functionality, this timer relay provides reliable operation for a wide range of applications where precise timing is crucial. The FCT18-AKR stands out for its exceptional versatility, offering time ranges from as short as 0.1 seconds to as long as 100 days, making it suitable for both rapid-response processes and long-term time-dependent operations.
Key Features and Benefits
Versatile Timing Function
The FCT18-AKR operates as an ON-delay timer with rising edge triggering, where the operating time is precisely controlled by the S (signal) input. When the Un (power supply) is applied and the S signal is triggered, the relay R activates after the pre-set time T has elapsed. This timing function is ideal for applications requiring delayed activation of equipment or processes.
Wide Time Range Selection
One of the most impressive aspects of the FCT18-AKR is its extensive time range flexibility:
- 0.1-1s: For quick response applications
- 1-10s: Ideal for short process delays
- 0.1-1m: Perfect for minute-based timing needs
- 1-10m: Suitable for medium-duration processes
- 0.1-1hr: For hour-based operations
- 1-10hr: Extended hour timing
- 0.1-1day: Daily cycle operations
- 1-10day: Multi-day timing requirements
- 3-30day: Monthly operational cycles
- 10-100day: Extended long-term timing
This remarkable range eliminates the need for multiple timing relays in systems with varying timing requirements, simplifying inventory management and reducing costs.
Adjustable Ratio Setting
The FCT18-AKR features precise ratio adjustment from 10% to 100% (in 5% increments), allowing for fine-tuning of the timing period within each selected range. This level of precision ensures that the relay can be calibrated to meet exact timing requirements for any application.
Universal Power Supply Compatibility
With a wide power supply range from 12V to 240V AC/DC, the FCT18-AKR offers exceptional installation flexibility, making it compatible with virtually any industrial power system worldwide. This universal power capability reduces inventory needs and simplifies specification.
Reliable Performance
The FCT18-AKR is engineered for reliability with:
- Time error less than 0.5%
- Time deviation of only 0.1%
- Repeat accuracy of 0.5%
- Strong anti-interference capability for stable operation in electrically noisy environments
Easy Installation and Setup
Installation and configuration are straightforward with:
- Easy-to-set time and ratio using the intuitive dial controls
- DIN rail mounting (EN/IEC 60715 compatible)
- Clear wiring diagrams provided on the side of the product
- Compact dimensions: 90mm × 18mm × 64mm
Durable Design
Built for industrial environments, the FCT18-AKR offers:
- Operating temperature range from -20°C to +60°C (-40°F to +85°F)
- Temperature coefficient of 0.05%/°C at 20°C (0.05%/°F at 68°F)
- Mechanical life of 1×10⁷ operations
- Electrical life of 1×10⁵ operations
- IP20 protection rating
- Pollution level 2 rating
Technical Specifications
Model Identification
The FCT18-AKR product code is structured as follows:
FCT18-AkR X Y Z
Where:
- Function: AkR – ON-delay timing function
- Output Type:
- 1: 1CO contact (1 SPDT)
- 2: 2CO contacts (2 SPDT)
- Supply Voltage:
- A: AC 230V
- D: DC 24V
- W: AC/DC 12-240V
- Control Signal:
- N: NPN
- P: PNP
Detailed Specifications
Parameter | FCT18-AkR1 | FCT18-AkR2 |
---|---|---|
Input Terminal | A1-A2 | A1-A2 |
Voltage range | AC 230V / DC24V / AC/DC 12-240V | AC 230V / DC24V / AC/DC 12-240V |
Power consumption | AC 3.5VA / DC 2.0W | AC 3.5VA / DC 2.0W |
Voltage tolerance | -15% ~ +10% | -15% ~ +10% |
Supply indication | Green LED | Green LED |
Relay indication | Red LED | Red LED |
Time ranges | 0.1s-100days | 0.1s-100days |
Time setting | Button | Button |
Time deviation | 0.1% | 0.1% |
Repeat accuracy | 0.5% | 0.5% |
Temperature coefficient | 0.05%/°C, at 20°C (0.05%/°F, at 68°F) | 0.05%/°C, at 20°C (0.05%/°F, at 68°F) |
Output contact | 1*SPDT | 2*SPDT |
Rated current | 1*16A | 2*16A |
Mechanical life | 1*10⁷ | 1*10⁷ |
Electrical life | 1*10⁵ | 1*10⁵ |
Ambient temperature | -20 … +60°C / -40 … +85°C | -20 … +60°C / -40 … +85°C |
Mounting | DIN rail EN/IEC 60715 | DIN rail EN/IEC 60715 |
IP Rating | IP20 | IP20 |
Stripping length | 7mm (0.28in) | 7mm (0.28in) |
Installed altitude | ≤2200m | ≤2200m |
Pollution level | 2 | 2 |
Max cable size | AWG13-20 0.4N·m | AWG13-20 0.4N·m |
Dimension | 90mm*18mm*64mm | 90mm*18mm*64mm |
Weight | about 90g | about 90g |
Standards | GB/T 14048.5, IEC60947-5-1, EN6812-1 | GB/T 14048.5, IEC60947-5-1, EN6812-1 |
Wiring Configurations
The FCT18-AKR can be wired in both NPN and PNP configurations:
NPN Configuration
- Connect power supply to terminals Un
- Connect control signal S
- Output connections: OA1 (DC+ / AC L) and OA2 (DC- / AC N)
- Terminal connections: 11, 12, 14, 21, 22, 24
PNP Configuration
- Connect power supply to terminals Un
- Connect control signal S
- Output connections: OA1 (DC+ / AC L) and OA2 (DC- / AC N)
- Terminal connections: 11, 12, 14, 21, 22, 24
Dimension
Applications
The FCT18-AKR pulse delayed timer relay is ideal for a wide range of industrial and commercial applications:
Manufacturing Automation
- Conveyor systems with timed operations
- Sequential machine operations
- Production line timing control
- Assembly line process coordination
Building Management
- HVAC system timing controls
- Lighting control systems
- Security system entry/exit delays
- Pump and motor control timing
Energy Management
- Power sequencing for equipment startup
- Load shedding timing
- Generator startup sequencing
- Energy conservation timing cycles
Water Treatment
- Pump cycle timing
- Filtration system timing
- Chemical dosing delays
- Backwash cycle control
Agriculture
- Irrigation timing systems
- Livestock feeding equipment timing
- Greenhouse climate control timing
- Aquaculture system timing
General Industrial Applications
- Motor start timing
- Process sequencing
- Time-based safety interlocks
- Equipment warm-up delays
Installation and Setup Guide
Mounting Instructions
- Mount the FCT18-AKR on a standard 35mm DIN rail according to EN/IEC 60715.
- Ensure adequate ventilation around the unit.
- For optimal performance, install in a location free from excessive vibration, dust, and corrosive gases.
Wiring Steps
- Strip wires to 7mm (0.28in) length.
- Connect power supply to the A1-A2 terminals.
- Connect control signal to the S terminal.
- Connect output devices to appropriate contact terminals.
- Ensure all connections are tight and secure.
Time Setting Procedure
- Select the appropriate time range using the main selector dial.
- Fine-tune the time value using the ratio setting dial (10%-100%).
- Apply power and verify correct operation by checking the LED indicators.
Troubleshooting Tips
Relay Not Activating
- Check power supply connections and voltage.
- Verify control signal is properly connected.
- Ensure time setting is appropriate for the application.
- Check for loose terminal connections.
Timing Inaccuracy
- Verify operating temperature is within specified range.
- Check for electromagnetic interference sources nearby.
- Ensure voltage stability within specified tolerance.
- Recalibrate time settings if necessary.
LED Indicators Not Working
- Check power supply connections.
- Verify voltage is within specified range.
- Contact support if indicators remain non-functional.
Maintenance and Care
The FCT18-AKR is designed for minimal maintenance. However, for optimal performance:
- Periodically check terminal connections for tightness.
- Keep the unit clean from dust and debris.
- Operate within specified environmental conditions.
- Record timing performance periodically to detect any drift.
Compliance and Certification
The FCT18-AKR timer relay is manufactured in compliance with:
- GB/T 14048.5
- IEC60947-5-1
- EN6812-1
These standards ensure reliable performance, electrical safety, and electromagnetic compatibility.
Warranty and Support
VIOX stands behind the FCT18-AKR with comprehensive warranty coverage and technical support. For detailed warranty information and technical assistance, please contact our customer service department or visit our website.
Conclusion
The VIOX FCT18-AKR pulse delayed timer relay represents the ideal solution for applications requiring precise timing control with versatile range options. Its wide operating voltage range, exceptional accuracy, and robust industrial design make it suitable for demanding environments across multiple industries. Whether your application requires millisecond precision or multi-day timing cycles, the FCT18-AKR delivers reliable performance to keep your systems running smoothly.
For more information about the VIOX FCT18-AKR or to discuss your specific application requirements, please contact our technical support team who can provide expert guidance on implementation and configuration.