ASTP-Y Time Relay

The VIOX ASTP-Y Analog Timer is a reliable and precise time delay relay designed for industrial automation systems and mechanical devices. This device counts down the set time and then switches the relay contacts, maintaining this position until reset. It features a time range of 0-60 seconds, adjustable via an analog dial, and is suitable for various applications requiring accurate timing control.

Send your requirements, we will quote for you within 12 hours​

VIOX ASTP-Y Analog Timer

Overview

The VIOX ASTP-Y Analog Timer is a reliable and precise time delay relay designed for industrial automation systems and mechanical devices. This device counts down the set time and then switches the relay contacts, maintaining this position until reset. It features a time range of 0-60 seconds, adjustable via an analog dial, and is suitable for various applications requiring accurate timing control.

Key Features

  • Precise Timing Control: Adjustable time range from 0 to 60 seconds with an analog dial.
  • Reliable Operation: Switches relay contacts after the set time and maintains the position.
  • Dual Relay Outputs: Two relay outputs with a maximum load of 5A each.
  • Easy Installation: Includes PF083A base for DIN rail mounting.
  • Visual Indicators: Front panel work indicator for easy monitoring.
  • Durable Construction: Designed for long-lasting performance with high mechanical and electrical life.
  • Wide Voltage Range: Operates on 230 VAC with a tolerance of +/-10%.

Specifications

CLASSIFICATION TIMER TIMER
MODEL ASTP-N ASTP-Y AH2-N AH2-Y
APPEARANCE
DIMENSIONS 61H×49W×70D 88H×58W×68D 61H×49W×70D 88H×58W×68D
MOUNTING
& SOCKET

SURFACE(-N) PF083A(E) PS-08 PF083A(E) PS-08
FLUSH(-Y) US-08 P3G-08 US-08 P3G-08
FULL TIMING RANGE SEC:1,3,6,10,12,30,60
MIN:3,6,12,30,60
HR:3,6,12,24
SEC:1,3,6,12,30,60
MIN:3,6,12,30,60
HR:3,6,12,24
RATED VOLTAGE DC(V):12,24 AC(V):12,24,110,220,240, 50/60Hz DC(V):12,24 AC(V):12,24,110,220,240, 50/60Hz
INDICATOR OPERATING Time Operating ON-UP Two indicator Lamp ON-UP
CONTACT MODEL ASTP-N1/ ASTP-Y1 ASTP-N2/ ASTP-Y2 ASTP-N/ ASTP-Y AH2-N1/ AH2-Y1 AH2-N2/ AH2-Y2 AH2-N/ AH2-Y
TIME LIMIT 1C 5A 5A 5A 5A
TIME LIMIT 2C 5A 5A
INSTANTANEOUS 1C 5A 5A
LIFE MECHANICAL 5×10times 5×10times
ELECTRICAL 10times 10times
ACCURACY REPEAT ERROR ±1% max ±1% max
SETTING ERROR ±10% max ±10% max
VOLTAGE ERROR ±1% max ±1% max
TEMP. ERROR ±2% max ±2% max
RESET TIME 0.1 sec max 0.1 sec max
CONSUMED POWER 2VA 3VA
AMBIENT TEMPERATURE -10℃~+55℃ -10℃~+55℃
AMBIENT HUMIDITY 48~85%RH 48~85%RH
WEIGHT 220g 220g
CONNECTION DIAGRAMS & TIMING CHART 39A 39B 39C 39D 39E 39F

Applications

The VIOX ASTP-Y Analog Timer is ideal for a variety of applications in industrial automation and mechanical devices. It is suitable for use in control panels, machinery, and other systems requiring precise timing control. The timer’s robust design and reliable performance make it an excellent choice for both commercial and industrial environments.

Technical Data

  • Power Supply: 230 VAC +/-10%
  • Output: Relay
  • Max. Load: 5A
  • Time Range: 0-60 seconds
  • Dimensions: 40×50 mm
  • Assembly: DIN Rail, In the table
  • Resolution: Analog Dial
  • Degree of Protection: IP 40
  • Mechanical Life: 5×106 times
  • Electrical Life: 105 times
  • Accuracy: Repeat Error: ±1% Max., Setting Error: ±10% Max., Voltage Error: ±1% Max., Temp. Error: ±2% Max.
  • Reset Time: 0.1 Sec. Max.
  • Consumed Power: 2VA
  • Ambient Temperature: -10℃ to +55℃
  • Ambient Humidity: 48% to 85% RH
  • Weight: 220g

Connection Diagram

The VIOX ASTP-Y Analog Timer features a straightforward connection diagram for easy installation. The device starts counting the set time when the power supply voltage is applied, then switches the relay contacts and remains in this position. Relay A1 operates according to the set time on the panel, while Relay A2 operates according to the timer power supply.

Output Modes

When the power supply voltage is applied, the device starts counting the set time and then switches the relay contacts, maintaining this position. Relay A1 works according to the set time on the panel, and Relay A2 works according to the timer power supply. Below is the operation diagram:

 