VIOX ELECTRIC
Język

Stycznik AC VIOX KCC6-M Compact

Compact 2P/3P AC contactors for circuit switching and motor
sterowania.

  • 9–38 A AC-3 at 380/400 V
  • Napięcie znamionowe izolacji 690 V
  • IP40 housing protection, excluding terminal connections
  • Rail or screw mounting; two compact frame sizes

Przegląd

VIOX KCC6-M compact AC contactors provide 2-pole or 3-pole switching
for remote circuit control and AC motor applications. The series covers
9–38 A AC-3 at 380/400 V, with a rated insulation voltage of 690 V and
rail or screw mounting.

Cechy

  • Selectable 2P and 3P main-circuit configurations.
  • Compact housing for cabinet installations.
  • IP40 protection excluding terminal connections.
  • Simplified construction without unnecessary auxiliary-contact
    konfiguracjami.
  • Multiple AC coil voltage options for control-circuit matching.

Specyfikacja techniczna

Model Prąd AC-3 przy 380/400 V Moc silnika AC-3 przy 380/400 V Prąd AC-3 przy 660/690 V
KCC6-M09 9 A 4 kW 6.6 A
KCC6-M12 12 A 5.5 kW 8.9 A
KCC6-M18 18 A 7.5 kW 12 A
KCC6-M25 25 A 11 kW 18 A
KCC6-M32 32 A 15 kW 22 A
KCC6-M38 38 A 18.5 kW 22 A

Motor power values are the catalogue’s three-phase AC-3 selection
values. They should not be used as single-phase ratings for the 2P
version. Select pole count and duty to suit the actual circuit.

Parametr Specyfikacja
Bieguny główne 2P / 3P
Znamionowe napięcie izolacji Ui 690 V
Main-circuit operating voltages in the rating table 380/400 V; 660/690 V
Ochrona IP40, excluding terminal connections
AC coil voltage options 24, 36, 48, 110, 127, 220/230, 240, 380/400, 415, 440 V
Opcje częstotliwości cewki 50 Hz; 50/60 Hz
Control-circuit operating range 70%–120% Us
Release range 20%–65% Us
Kategoria instalacji III
Stopień zanieczyszczenia 3
Montaż Szyna lub śruba

Wymiar

Frame group Amax Bmax Cmax a b1 b2 Średnica otworu
09, 12, 18 33 74 74 24 56 65 4.5
25, 32, 38 45 80 83 35 48 65 4.5

Dimensions in mm. Match the frame group and pole configuration to the
supplied installation drawing.

KCC6-M contactor outline and mounting dimensions

Informacje o zamawianiu

Specify the KCC6-M model, 2P or 3P configuration, load voltage and
utilization category, control coil voltage and frequency, mounting
requirements and quantity when requesting a quotation.

Potrzebujesz wyceny produktu?
Zbudujmy to razem.

Prześlij nam model produktu, parametry techniczne, ilość oraz wymagania OEM. Nasz zespół przeanalizuje Twoje zgłoszenie i odpowie w ciągu jednego dnia roboczego.

Zapytanie ofertowe