VIOX ELECTRIC
언어

VIOX VSP-T25/B+C 690V / 760V High-Voltage AC Type 1+2 Industrial & Wind SPD (25kA)

The VIOX VSP-T25/B+C (690 V / 760 V) is a high-voltage AC Type 1 + Type 2 lightning and surge arrester specifically built for 690 V AC wind turbines, utility-scale solar central inverter AC outputs, heavy industrial VFDs, and mining switchboards. Rated for Uc 690 V / 760 V AC, Iimp 25 kA (10/350 μs), Imax 50/120 kA (8/20 μs), Up ≤2.0 kV, and 50 kA Isccr.

VIOX 시리즈
VSP-T25/B+C (690V / 760V)
정격 전압
AC 690V / 760V (IT / TN-C)
Surge Rating
Iimp 25 kA · Imax 50/120 kA
준
IEC 61643-11 · T1+T2 · 690V/760V

개요

The VIOX VSP-T25/B+C (690 V / 760 V) is a high-voltage AC Type 1 + Type 2 lightning and surge arrester specifically built for 690 V AC wind turbines, utility-scale solar central inverter AC outputs, heavy industrial VFDs, and mining switchboards. Rated for Uc 690 V / 760 V AC, Iimp 25 kA (10/350 μs), Imax 50/120 kA (8/20 μs), Up ≤2.0 kV, and 50 kA Isccr.

특징

  • Dedicated high-voltage AC ratings: Uc 690 V and 760 V AC for 690 V industrial motors, wind turbines, and 800 V-class solar inverter AC panels.
  • Type 1 + Type 2 dual protection: Iimp 25 kA (10/350 μs), In 25/50 kA, and Imax 50/120 kA (8/20 μs).
  • Low Up 2.0 kV protection level with high-energy MOV + GDT hybrid architecture and zero residual leakage current.
  • 50,000 A short-circuit rating (Isccr) with optional 11/12/14 remote alarm signaling across 1P–4P configurations.

사양

VSP-T25/B+C (690V / 760V) Electrical & Mechanical Specifications

매개변수사양
SPD ClassificationType 1 + Type 2 (T1+T2) High-Voltage AC · IEC 61643-11
Max Continuous Operating Voltage (Uc)690 V AC / 760 V AC
Lightning Impulse Current (Iimp, 10/350 μs)25 kA
Nominal / Max Discharge Current (8/20 μs)In 25 / 50 kA · Imax 50 / 120 kA
전압 보호 수준(Up)2.0 kV · Response Time: 25 ns
Short-Circuit Rating & LeakageIsccr 50,000 A · Ipe: NONE · Recommended SCB: VSP-SSD50X
Dimensions & Terminals36 mm/pole (90 × 92 mm) · 6–35 mm² (2.5 N·m) · Black PBT UL94 V-0

VSP-T25/B+C (690V / 760V) Available Poles & Dimensions

폴란드1P2P3P4P
Dimensions (W × H × D)36 × 90 × 92 mm72 × 90 × 92 mm108 × 90 × 92 mm144 × 90 × 92 mm

치수 및 설치

VIOX VSP-T25/B+C 690V / 760V High-Voltage AC Type 1+2 Industrial & Wind SPD (25kA) Dimensional Drawing (mm)
VSP-T25/B+C (690V / 760V) Outline & DIN-Rail Mounting Dimensions (unit: mm)
  • Designed for 3-phase 690 V AC IT/TN-C industrial networks, wind nacelle cabinets, and utility PV inverter AC combiner panels.
  • Use ≥16 mm² phase and earth wiring with shortest possible lead length.
  • Explore the complete VIOX Surge Protection Devices (SPD) catalog for matched AC, Solar PV DC, and SCB backup protection.

자주 묻는 질문

Can a 440V SPD be used on a 690V AC solar inverter output or wind turbine?

No. A 440 V SPD will immediately conduct and fail catastrophically on a 690 V AC system. Always specify Uc 690 V or 760 V (VSP-T25/B+C-690/760V).

제품 견적이 필요하신가요?
함께 만들어 갑시다.

제품 모델, 기술 정격, 수량 및 OEM 요구 사항을 보내주십시오. 당사 팀에서 귀하의 애플리케이션을 검토한 후 영업일 기준 1일 이내에 답변해 드리겠습니다.

견적 요청하기