VIOX ELECTRIC
언어

VIOX 690VAC 160A NT00 HRC Fuse

NT00 VIOX 690VAC 160A NT00 HRC Fuse is generally designed to cover a wide range of protection for most of industrial applications with different operating class such as gG/gL, aM and aR. This square body with blade terminals fuse was made in a standardized configuration for global.

VIOX 시리즈
NT00
정격 전압
690VAC
정격 전류
160A
준
IEC60269-1 / IEC60269-2

개요

NT00 VIOX 690VAC 160A NT00 HRC Fuse is generally designed to cover a wide range of protection for most of industrial applications with different operating class such as gG/gL, aM and aR. This square body with blade terminals fuse was made in a standardized configuration for global acceptance. 690VAC 160A NT00 HRC Fuse is available in multiple ampere ratings from 4A up to 160A, which helps match specific requirements in various industrial applications, such as motors, transformers, low voltage distribution, control circuits and so on.

특징

  • IEC60269-1
  • IEC60269-2
  • Rated voltage 690VAC and current capacity 160A for low-voltage hrc industrial fuse applications.
  • High interrupting performance (High Breaking Capacity) with rapid current-limiting fault clearing.
  • Engineered and tested in accordance with IEC60269-1 / IEC60269-2 standards.
  • Precision-engineered low-power-loss silver-plated contacts and high-temperature ceramic or flame-retardant housing.

사양

NT00 Technical Specifications

Model/Size 정격 전압(V) 정격 전류(A) 전체 차원
A D E H H1 H2
NT00 500/690 (4~100), 125, 160 78 49 29 56 15 45

NT00 Ratings & Dimensions Table 2

Model/Size 정격 전압(V) 정격 전류(A) 전체 차원
YR:Sist101 690 160 Fig.2

Selection & Installation Notes

  • Verify system maximum voltage (690VAC) and prospective short-circuit fault current before selecting the fuse link or holder rating.
  • Apply ambient-temperature derating when operating inside sealed outdoor combiner boxes or high-density inverter cabinets above 40°C.
  • Always de-energize circuits before replacing cylindrical, blade, or bolted fuse links, and use insulated fuse pullers for NH/NT types.
  • Explore the complete VIOX Fuse & Fuse Holder catalog for matched holders, bases, and disconnectors.

자주 묻는 질문

What voltage and current ratings does the VIOX 690VAC 160A NT00 HRC Fuse support?

This VIOX NT00 series is rated for 690VAC with a current rating of 160A and High Breaking Capacity breaking performance. Refer to the technical specification table above for individual part numbers and ampere steps.

Which international standards apply to VIOX 690VAC 160A NT00 HRC Fuse?

The NT00 series is designed and verified to IEC60269-1 / IEC60269-2 requirements for safe overcurrent and short-circuit protection.

Where is the VIOX 690VAC 160A NT00 HRC Fuse typically installed?

It is engineered for low-voltage hrc industrial fuse circuits, protecting cables, busbars, semiconductors, battery modules, or string feeders against thermal overload and high-energy short-circuit faults.

Can VIOX supply matched fuse holders, bases, or OEM private-label packaging?

Yes. VIOX Electric supplies matched DIN-rail fuse holders, NH/NT fuse bases, disconnectors, and OEM/ODM bulk packaging with technical datasheets upon RFQ.

제품 견적이 필요하신가요?
함께 만들어 갑시다.

제품 모델, 기술 정격, 수량 및 OEM 요구 사항을 보내주십시오. 당사 팀에서 귀하의 애플리케이션을 검토한 후 영업일 기준 1일 이내에 답변해 드리겠습니다.

견적 요청하기