α RCBO ααΊααΆα§αααααααΆααα ααααα’αααα·αααΈαααααΆαααΆαααΆαααα ααααΆαα αααααα½αααΆαα½αααΆαααΆαααΆαααΎαα ααααα αααα»ααααααΆααααααα ααΆααΆααα½ααααα αΌααα»αααΆαααααΎαααΆαααα ααααΆαα αααααααα RCD/RCCB ααΆαα½αααΉααα»αααΆαααΆαααΆαααΆααααα»αααΎαααααα·α αα·αααΆαααααα ααααααααΈαααα MCB αα αααα»αα§ααααααααα½αααααααααΎαααΎαααααα DIN-railα.
αααααΆααααααΆα’ααααα·αα’αΆα ααααΎαααΎα RCBO αααααα’ααααΎαααααΆααα’αααααααα½ααα»αααΆαααα ααΆαααααΎαααΎα RCBO ααααΉαααααΌαααααΌαααααααΌαααααα ααΉα ααααααααααΆαααΆαααΈααααα»αααααααα½α:
- the αααααααα ααααΆαα αααα: αααααα RCD, ααααα·αααΆααααααααα½α, α ααα½ααααΌα, ααΆααααα αααααααΊα (Neutral), αα·αααΆαααΎαα’αΎα (Selectivity)
- the αααααααΎαα αααα: α ααααααααα, αααααααααΆααα αααα (Trip curve), αααααααΆαααΆααα αααα, ααα»αααααα, αα·ααααααααΆααααααΆααααααα
αααααΆααα’αααααΆααααααααΆαααααααΆ, α’αααααααΆαα’αααα·αααΈ, αααα»αα αα»αααα·αα§αααααααΎα (OEMs), αα·αα’αααα ααα αΆα, ααααΎαααΆαααααΎαααΎαααααα’αααα»αααΊααΆααααα α αΆααααααΎαααΈααααααΈ αα·αααααα»αα’αααα·αααΈ αααααΆααααααααΎαααΎαααααααααα ααααΆαα αααα, ααααα·αααΆααααααααα½α, α ααααααααα, ααααααα, ααΆαααααααα ααΆαααααααααααΌα, αα·ααααααααΆαααΆααα ααααααΆαααααΆααααααααααα.
ααααα·αααΎα’αααααααΌαααΆαααααααΆααααααααα’ααααααΆαααα»ααααααΆααα αααααΆαααααΎαααΎα VIOX ααααΆαααΆαααααααααΆα ααααα‘αααα½αα’αααΈ αααααααααααααα RCBO αα αααα»αααααααααα’αααα·αααΈ.
αααααΉαβαα
- ααααααααΆαααΆααααααΆααααΌα ααααΆααΉαααααα·αα ααααα’αααα·αααΈαααα. RCBO αααααα AC, A, F αα·α B α’αΆα α αΆαααααααΆαααα ααααααααα ααααα»ααααααΆα.
- 30 mA ααΊααΆααΌαα αααααΆααααΆαααΆαααΆαααααΆαααααα½ααααααα, ααααααααα 100 mA αα·α 300 mA ααααΌαααΆαααααΎααΆααααααΆαααααΆααααααααααααΆαααΎ ααΆαααΆαααΆαα’ααααΈααα α¬αααααα·ααΈααααΎαααΎαα’αΆαααααααΎα αααΆαααααα»ααααααα.
- ααααααα B, C αα·α D ααΊααΆαααααααααααΆαααΆααα ααααααΎα, αα·ααααααΆααΆααααααααα½αααα ααααααα ααααΆααααααα.
- ααααα·αα αααααααα RCBO ααααΌαααααΆαααΆααααΈαααααΆααααααΆααΆαα½αααΉαααααααααΎα, αα·ααααααααΆααααααα’ααααΎα§ααααααααααααΆααααααΆαα½ααααααα.
- αααααααΆαααΆααααααΆα αα αααα (Breaking capacity) ααααΌααααααααααΆαα ααααααααααΆααααααααΈααααΈ (Prospective short-circuit current) αα αααααα ααα»α ααα‘αΎαα.
- ααααΆααααΆαααααααα’αααα·αααΈ (EV chargers), α’ααΈαααΊααααααΆααααααααΊααααα’αΆαα·ααα (PV inverters), α§αααααααααααααααααα (VFDs) αα·ααααΆαααΈαααΌαααααα (Heat pumps) ααΆαααΆαα±ααααΆαααΆαααααΎαααΎααααααα RCD ααααααα»ααααααααα αααααΆαα ααααααα ααααΆααααααα DC α¬ααααααααααααα’αΆα αααααΆαααααααααα·ααααα·ααΆααααα RCD ααΌαα α.
αααααΈαααα½ααα·αα·ααααααααΆααααΆαααααΎαααΎα RCBO

| αααααΆααααΎαααΎα | α’αααΈαααααααΌααα·αα·ααα | αααααΎαααααααΆ | ααα α»αααΌαα |
|---|---|---|---|
| ααααααα ααααααα | ααΌαααΆααααααα ααααααα ααααΆααααα’αΆα ααΎαααΆα | αααααα AC, A, F, B | ααΆαααααΎααααΆαααααααα AC ααΎααααααΈαααααΆαααααα»αα’αα‘α·α ααααΌαα·αααααααα ααααΆααααΌαααΆααααααα A, F α¬ B |
| ααΆααααΎα | α
ααααααααα·ααααα·ααΆαααααααααααΆαααααα (Rated residual operating current), IΞn |
10 mA, 30 mA, 100 mA, 300 mA | ααΆαααααΎαααΎααα 10 mA αααααααΈααααααααααααααΆαα±ααααΆαααΆαααΆααααααΆα ααααααααΆαααΌαα ααα» (Nuisance trips) |
| ααΆαααααααα αα α»αααααα | α αααααα ααΆααααααΈ αα·ααααααααΆααααα»αα ααααααααααααα ααα | 6 A ααα 63 A αααααΆααΌαα ααααΎαααα»αααααααΈα α»αααααα | ααΆαααααΎααααΆαα RCBO αααααΆαααα αααααα ααααααααΆαα±ααααααααααΎααα·αααααΌαααΆαααΆαααΆαααααΉαααααΌα |
| αααααααααααΎααααΎα | α ααααα αΆααααααΎαααααααααα»α (Inrush current) | B, C, D | ααΆαααααΎααααΆααααααααααααααα B ααΎα§ααααααααααΆαα ααααα αΆααααααΎαααααα α¬ααααααααααααα D αααα»αααααΈαααα ααααααααααΆααααΆαααααα·αααΆαααα |
| αααααα | ααααααΆααααααααΌαααααΎααΆαααΆααααααΆα α αα·ααααα½ααα·αα·ααα | 1P+N, 2P, 3P+N, 4P | ααΆαααΆααααα αΌαααααΆααααααααΊα (Neutral) αααΆαααααααΈαααααΆαααΆαααα RCBO |
| αααααααΆαααααα | α ααααααααααΆαααααααααΉααα»ααα αααααααααΆααα ααα αΆαααααΎα (Prospective short-circuit current) | 6 kA, 10 kA, 16 kA αα·ααααααααΆαααα | ααΆααααααααααααα·α 6 kA α¬ 10 kA ααΆααααα·ααααααααΆαααΌαα |
| αααααααΆα αα·αααΆααααααΆαα | αααααααΆαααα·ααα αα·ααα·ααΆαααΆαααααΆαααααΎααααΆαα | IEC/EN 61009-1, IEC 62423 αααα»αααααΈαααα’αΆα α’αα»ααααααΆα | ααΆααααααααΆ RCBO ααααααααααααα»ααααααααααααααααΆαααααααααα·ααΆααΆαααα‘αΎα |
ααα αΆαααΈ 1α αααααααααααααααααΈα’αααα·αααΈαα»ααααααααΎαααΎα RCBO
αα»ααααααααΎαααΎααααΌααα ααΌαααααααα»αααΆαααΆαααααααααααααααΈα
- ααααααααααααααααααα α αααΆααααα½α (single-phase), α αααΆαααΈ (three-phase), ααΆα α¬ααααΆαααααααΊα (neutral)
- ααααααααααα»αα α’αααΌαααααΎα, ααααααα, ααααααααααααα , ααααα, αααΌααα, ααααΆααααΆαααααααα’αααα·αααΈ (EV charger), α’ααΈαααΊααααααΆααααααααΊααααα’αΆαα·ααα (PV inverter), αααααααααα (heat pump), α§ααααααααααΆααααΏααααΌααα (VFD) α¬ααααα»αα αααα»α
- α αααααα ααΆαααααΆααααααααΈ
- ααα αααααα αααα αα·ααΈααΆαααααααα‘αΎα ααΈαα»ααα ααΆααα»ααα·α αα·ααααααΆααα α»ααααααααΆα (derating factors)
- α ααααααααααΆααααααααΈααααΈαααααΆααα ααααΆααα ααα αΆαααΆααα
- α ααααααα ααααΆααααααααΉααα»αααΈααααα ααααααααΎαααα ααααΏαα’αα‘α·α ααααΌαα·α α¬α§αααααααΆα αααΎαααααααααΆααααΆαα½αααααΆ
- ααΎααααααΈαααααΆαααΆααααααΆααα αααααα»ααααα·ααΆα α¬αα½ααααα ααΆα ααααα‘ααααΈααααααΈαααααααααα¬αα
αααααΊααΆα ααα»α ααα RCBO αααααααΆαααααα·αααααΆαααΆαααΆαααααΎ RCCB αα½αααΆαα½α MCB α αααΎαα ααΆαα½αααΉα RCBO ααΆα ααααα‘ααααΈααααΆ ααΆαααα ααααΆαα ααααααΆααααααΆααΉαααΆααααααΆα αααααααααΈαα½αααα»ααααα αα·ααααααΆααααααΆα αααΆαααααα»ααααααα αααααΆααααΆααααααααααα ααΆαααααααα ααΌαααΎαααΆαααααΆααααα VIOX RCBO αααααΉα RCCB αα·α MCB.
ααα αΆαααΈ 2α ααααΎαααΎααααααα RCBO α±ααααΆαααααΉαααααΌα
αααααα RCBO αααα αΆαααΈαααααααααααα ααααααααα ααα (residual-current) αααα§αααααααααΌαααΆααα ααΆα‘αΎαααΎααααΈα αΆαααααααΆα αααααΊαα»αααααΆααΈαααααααα ααααααΎα (overcurrent curve) αααααα B/C/Dα.
| αααααα RCBO | ααΆαααααΎαα ααααααα ααααΆα | ααΆαααααΎααααΆααααααααΆα | ααΆααααα»ααααααααααααα»αααΆαααααΎαααΎα |
|---|---|---|---|
| ααΆα AC | α ααααααα ααααΆααααααα AC ααααααΈαα»α (Sinusoidal AC) | ααααααΈ AC αααααααααααΈαααααααΆαααα αααααααΌαααΆαα’αα»ααααΆα | αα·ααααααα·αααααααΆααααααα»αα’αα‘α·α ααααΌαα·αααααΎαααΆαα αααΎα |
| αααααα A | α ααααααα ααααΆααααααα AC ααααααΈαα»α αα·α DC α ααααΆαα (Pulsating DC) | ααααααΈααΌαα αααααΆαα§αααααα’αα‘α·α ααααΌαα·α, α§ααααααααααααΌαα αααα (Rectifiers), α§ααααααααααΆ LED, αααΆαααΈααααααα’αΆα, αα·αααααα»αα’αΆαααα»α αααα»α | ααΆααΌαα ααΊααΆααααα·αα’αααααααΆαααααΆααααααααααααΆααααααααΈα α»ααααααααααΎα ααα»αααααα αααα·ααααααααααΆαααααααΆααα ααααααα ααααΆααααααα DC αααΌα (Smooth DC) |
| αααααα F | α₯αα·ααΆαααααααα A ααΌααα½αααΉαα ααααααα ααααΆααααααΆααααααααα αααα»ααααααΆαααααΎαααΎα αα·αααΆααααααα’α₯αα·ααΆααααΆαα½αααααα»αα’αΆααααΊααααααααΆααααΆααααα½ααα½αα ααα½α | αααΆαααΈαααΌαααααα αααΆαααΈααααααα αα·αα§ααααααααα»αααααΏαα’αααααααΆααααΆααααα½α αααα»αααααΈαααααΆαααΆααααααΆαα | αααααααααΆααααΆαααααΆαααααα’αααααα·αα§ααααα |
| αααααα α | α ααααααααΆαα (AC) α ααααααααΆαααααααΎαααΆα ααααΆαα (pulsating DC) αααΆαααΆαα»αααααααααααα αα·αα ααααααα ααααΆαααααααα ααααααααΆαααααΌα (smooth DC) | ααΆαααΆααααααααααα’αααα·αααΈ (EV) α’αΆααααΊααααααΆααααααααΊααααα’αΆαα·ααα (PV) α§ααααα VFD α§ααααααααααααΆααααα α¬α§αααααα§ααααΆα αααα αααα’αΆα ααΆαααΆαααα ααααΆαα ααααααααΆαααααΌα (smooth DC) | ααΆααααααααααααΆα αα·αααΆααααααααα·αααααΆα; ααααΎαααΎααα ααααααααΆαααααΎααααΆαααα·αααΆαααααΌαα±ααααΆαααΆ |

ααΆα AC RCBO
RCBO αααααα AC ααααΎαα ααααααα ααααΆαααααααααααΆαααααΈαα»αα αα½αααΆα’αΆα αα ααααΆαααααααΆααα αααα»αααΆαααα‘αΎαα αΆααα α¬ααααααΈααΆαααα ααα»ααααααΆαααααΎααααΆααααααααΆααααΌαααΆαααααα·αααΆααααααααΆααα‘αΎααα αααα»ααααααα·ααΈααααΎαα αααααΆαααααα»αααΆα αααΎαααΆααααα»αα§ααααααααααααΌα (rectifiers) ααΆαααααααααααααΆαααα’αα‘α·α ααααΌαα·α ααααα (filters) αα·αααααΆααααΆαα’αΆααααΊααααα.
αα»αααααΎαααΎααααααα AC ααααΆαααααααααΆαααΆααΆαααααΎααααααΆααααααααααααα»αα ααΌααααααααααΆααααΆααααα»ααααααΆααααααΆαα αα·ααααααααααααα·ααααΆααααααΆααααααααααΎααααα»αααΌαααααΆαα’αα»ααααΆαα±ααααααΎααααΆααααΆα.
ααΆα A RCBO
RCBO αααααα A α’αΆα α αΆαααααααΆα ααααααα ααααΆααααααα AC ααααααΈαα»α αα·αα ααααααα ααααΆααααααα DC αααααΆαα ααααΆααα ααΆααααΌαααΆαααααααΎααααΆααααΆααΌαα αααααΆααααααααΈα α»ααααααααααααααααααααΎαααααΆααααΆααααα½α (single-phase) αααα»αααααααααΎα αααααΆαααααα»αααααΎααααΆαααααα»ααααα ααΆαα·ααααααα αα·αα§ααααΆα ααααααααΆαααΌα αααααααΆααααΆαααΆαα’αα‘α·α ααααΌαα·αα.
ααΆααΌαα αααααα A ααΊααΆαααααΎααααααΆααα»ααααα·ααΆαααΆααααααα AC αααααΆααααααααΈααααΎαααΆααααα αα α»αααααα ααα»ααααααΆαα·ααααααΆαααααααααΆααααααΆαααααααααααΈαααααα ααααα·αααΎα’αΆα ααΆαα ααααααα ααααΆααααααα DC αααΌα α¬α ααααααα ααααΆααααααΆααααααααααααα ααααααααα F α¬αααααα B α’αΆα ααΉαα αΆαααΆα αααααΌαααααΎααααΆααα.
RCBO αααααα F
RCBO αααααα F ααααΌαααΆαααααΎααααΆαααααα»αααααΈαααααααα»αα’αΆα αααααΎααααΆαααΆαα ααααααα ααααΆαααΎαααΈαααααααΆααααααααααα A ααΆαα·αααα§ααααααααααααΎααααΆαα Inverter ααααΆααααΆααααα½αα α§ααΆα ααααα½αααΆα αααΆαααΈαααΌαααααα (heat pumps) αααΆαααΈααααααα’αΆα α§ααααααααΆαααΈααααααΆαα αα·αα§αααααααααΎααααΆαααααααΆαααααΏαα’αααα.
ααααΎααααΆαααααααα F αα αααααααααα»αα αα»αααα·αα§ααααα αααααααααα αα ααααααααααααα α¬αααααααααααα·αααα»αααΌαααααΆααααααΌαα±ααααααΎααΌα ααααα αα»ααααααααΆαααααααααααΈαααΌααα α¬α§αααααααααΎααααΆααααΆααα’αααα»αααααααααΌαααΆααααααα F αααααααααααααααα·α.
αααααα B RCBO
RCBO αααααα B α’αΆα α αΆαααααααΆα ααααααα ααααΆαααΆααααα»αααααα·αααΌααααΌααΆαααΆα αα½αααΆαααααΆαααΆα DC αααΌααααααα ααΆααααΌαααΆααααα·α αΆαααΆααααΎααααΆααααΆααΉαααΆαααααααΆααα§αααααααΌα ααΆ ααααΆααααΆαααααααα’αααα·αααΈ (EV chargers) αααααααα Inverter ααΆααααααααΊααααα’αΆαα·ααα (PV inverters) α§ααααααααααααααααααα αα·αααααααααα§ααααΆα αααα α¬αααααααΆααααααα½αα ααα½αα.
α ααα»α ααααΆαααα·αααααααα·αααααΉαααααααααααα·ααααααααα αααα½ααα·αααααΆααααΊααΆααΎα§ααααααααα’αΆα αααααΎαα ααααααα ααααΆααααα’αΆα ααααΎα±ααα§ααααααααααα AC α¬αααααα A ααΌα αα»αααΆα α¬ααα’αα (saturate) ααΆααααα¬ααα αααααΆααααΆαααΆααααααααααα’αααα·αααΈ αααααααααΆαααααΉαααααΌαα’αΆα ααΆαααααα B, αααααα A αααααΆααα»αααΆαα αΆαααααααΆα ααααααα ααααΆα DC 6 mA, αααααα A-EV α¬α§αααααα αΆαααααααΆα ααααααααΆααααααα½ααααα αΌααααα»αααααΆααααΆα αααα’αΆαααααααΎα§ααααα αα·ααααααααααααα·αααα»αααΌαααααΆαα αααααΆααααααααΆααααα’α·αααααααα’αααΈααΆαααααΎααααΆαααααααΆααααααααα’αααα·αααΈ ααΌαααΎα ααΆαααααΎαααΎα RCD αααααΆααααααΆααααΆαααααααα’αααα·αααΈ (EV): αααααα B αααααΉα αααααα F αααααΉα αααααα EV.
ααα αΆαααΈ 3: ααααΎαααΎαααααα·αααΆααααααααα½α (Sensitivity) αααα RCBO
ααααα·αααΆααααααααα½ααααα RCBO ααΊααΆα
ααααααααα·ααααα·ααΆααααααααααααΆαααααα αααααΆααΌαα
ααααΌαααΆααααααααΆ IΞn. ααΆαααααααααα·αα
ααααααααααααααα»αααΆαααΆαααΆαααΆαααα
ααααΆαα
ααααααααΌαααααΎααΆαααΆααααααΆα
α (Trip).
| ααΆααααΎα | αα½ααΆααΈααααααΆ | ααΆαααααΎααααΆααααΌαα | ααΆααααα»αααααααααααααΆαα |
|---|---|---|---|
| 10 mA | ααΆαααΆαααΆααααααΆαααααα·αααΆααααααααα½αααααα | ααααααΈαα·ααα ααααααααααΆαααααΎα ααααααα·αααααααααααΆααΆα α¬α§ααααααααααΆαα αΆαα·αααααααααααα»αααΌαααααΆαααΆαααΆαααααα | ααΆαααΉαααΆαααΆαααΆααααααΆα ααααα ααααα (Nuisance tripping) αααααΆαααΆαααα ααααΆαα ααααααααααΆ |
| 30 mA | ααΆαααΆαααΆααααααααααααΆαααα»αααα | ααααααΈα α»αααααα ααααααα ααααααΈαααα αααα αα·αααααααΈαααα ααααΆα α¬ααΆαα·αααααααααΆα αααΎαααα | αα ααααααΌααα·αααΌαααΈααΆαααα ααααΆαα ααααα’αααα·αααΈαααααΎαα‘αΎαααααα |
| 10 mA | ααΆαααΆαααΆααα αααααααΆαααΎ (Upstream) α¬ααΆαααΆαααΆαα§ααααα | ααααααΈα ααα αΆα ααΆααααα αααααααααααααΎαααΎα αα·αααααα»ααα·ααααα½αα ααα½α | ααΆααΌαα αα·ααααααΆααΆααααα½ααααααΆααααΆαααΆαααΆααα»αααααα ααααααΈα α»ααααααααααα·α 30 mA ααααα |
| 300 mA | ααΆαααΆαααΆαα αΆαα·αααα’ααααΈααα αα·αααΆαααΆαααΆααα αααααααΆαααΎ (Upstream) | ααΆαααΆαααΆααα ααααΆααα ααα αΆααα α¬ααααΆααα ααα αΆααα αα»αααααΆααααααααααααα TT αα·αααΆαααΆαααΆαα’ααααΈαααααΆαααΆαααααα | ααΆαααΆαα±ααααΆαααΆααααααααααα½αααΆαα½αα§ααααααα αααααααΆαααααα (downstream devices) |
αααααΆααααααααΈα α»αααααααααααΆαααΆαααΆαααΆαααΆαααΆααααα’αααα·αααΈαααααΆααααα»ααα ααααα 30 mA ααααΌαααΆαααααΎααααΆαααααΆαααΌααααΌααΆααα αααα»αααΆαααα‘αΎαααΆααααααααΆα IECα αααααΆαααΆαααΆααααα ααΆαααααΎαααΎαα α»ααααααααααΌαααα’αα»ααααααΆααααααααααααα·αααα»ααααα»α ααααααααα α»αααΈ (earthing system) αααααααααααααααΈ αα·αααΆαααΆααααααα αΆαα·αααα.
ααααααααααααΆααααααΌα ααΆ 100 mA αα·α 300 mA ααΆααααααΆααααΌαααΆαααααΎαααΎααααααΆααααΆαααΆαααΆααα αααααααΆαααΎ (upstream protection) ααΆαααΆαααααααα αΆαα·αααα’αααα·ααα α¬ααΎααααΈαααααΎαααΆααα»αααααΆαααααααααΆααααα·ααααα·ααΆα (discrimination) ααΆαα½αα§ααααα 30 mA αα αααααααΆααααααα αα αααα»ααααααααΆααααα α§ααααααα αααααααΆαααΎαααααΆααα»αααΆααααααΆαααα (time-delayed) α¬αααααα selective α’αΆα ααΉαααααΌαααΆα ααΎααααΈααΆααΆααΆ RCBO αα αααααααΆααααααααΆα ααα»αα.
αααααΆααααΆααα·ααΆααααΆαααα’α·αααααααα’αααΈααΆααααααααα½α (sensitivity) ααΌαααΎαααΆαααααΆααααα VIOX ααααΈααΈ ααααααααΎαααΎαααΆααααααααα½α RCCB ααααΉαααααΌα.
ααα αΆαααΈ 4α ααααΎαααΎαα ααααααααα (Rated Current)
α ααααααααααααα RCBO ααΊααΆα ααααααααααααααΆαααΆαααΎαα αααα (overcurrent section) ααααΌαααΆααα ααΆα‘αΎαααΎααααΈαααα»αααΆαααααααααΆααααααααααααααααααααΆααααααα ααΆααααΌαααααααΎαααΎααααααα’ααααΎααααααΈααΆααααΌα αα·ααααααα’ααααΎααααααΆααααααΆααααα§αααααα’αααα·αααΈαααααα.
αααααΆααααΆααα ααΆααααααΈααΆααααααααΆα IEC αααααα·ααααΆααΌαααααΆαααΊα
IB β€ In β€ IZ
ααααααααΆα
IB= α αααααα ααΆαααααΆααααααα»ααααα»α= α ααααααααααααα RCBOIZ= αααααααΆααααα»αα ααααααααααααααααΎα αααααΆααααΈααΆαααα‘αΎα αα·ααααααΆααα α»ααααααααΆα (derating factors)
αααααΆααααααΆ ααααα·αα αααααααα RCBO ααααΌαααααααααααααααααΆαααααααΆααααααα»ααααααΆαααααα ααα»αααααα·αααααΌααααααααααα αΌααααααααααααΎααα·αααααΌαααΆαααΆαααΆαααααΉαααααΌααααααα.
α ααααΆαααΆαααααΎα αααΆαααααααΌα ααΆ βαααα 2.5 mmΒ² ααααΎααΉα 20 A ααΆαα·α αα β α¬ βαααα 1.5 mmΒ² ααααΎααΉα 16 A ααΆαα·α αα β ααααα·αααΆααα·αα·αααααΎαα·ααΈααΆαααααααα‘αΎα ααααααα’ααΈααΌα‘αα ααΆαααΆααααΆαααα»α ααΈαα»ααα ααΆααα»ααα·α αααααααααααα·αααα»ααααα»α αα·ααααααΆααα α»ααααααααΆαααααααααΎαα ααααΌαααΆααααΆαααααααΊααΆααΌαα ααα»αααααααα±ααααΆααααα αΆααααα ααααΆαααα αααα»αααΌααααΎαααΆαααααααα.
ααα αΆαααΈ 5α ααααΎαααΎααααααααααΆααα αααα (Trip Curve): B, C, α¬ D
αααααααααΆααα ααααααΊαααα·ααα ααΎαααααααΆαααΆαα ααααααΎααααα RCBOα ααΆαα·αααααΆα’αααΈααααα·ααααααααΆαααΆααα ααααααααααΆαααα·αααααΆαα αα αααααΆαααΆαααααα ααααααααΈ (short-circuit) α¬αααααααααααααΆαα ααααα ααα‘αΎαααααα (high-inrush)α.
| ααααααα (Curve) | αα½αααααΆαααΆααααααΆα αααααΆαα (Instantaneous trip range) | ααααα»αααααααΆ | α αΆαα·ααααααα»αααΆαααααΎαααΎα |
|---|---|---|---|
| ααααααα B | αααα αα α£ αα
α₯ αα αααα»α |
ααααα»αααα (Resistive loads), ααααααααααααΎαααααααΊ, ααααααΈα α»αααααααααααΆαα αααααααα (inrush) ααΆα | α’αΆα ααΆαααΆαααΆα αα ααααααααα·αα αΆαααΆα α (nuisance trip) αα ααΎαααΌααα, αααααααααα, α¬ααααα»ααααααΆααααααααΆαα’αααα·αααΈααααα (large capacitive loads) |
| ααααααα C | αααα αα α₯ αα
α‘α αα αααα»α |
αααααααααααΎαααΌαα , αααΌαααααΌα α, ααΌαααααΎαααΆαα·ααααααα, ααααα»ααααααΆαα ααααααααααααα | αα ααααααΌαααΆα αα ααααα±ααααΆαααΏααααααααααΆαααααα»αααααααααααΆαααΆαααααα αααα (fault conditions) |
| ααααααα D | αααα αα α‘α αα
α’α αα αααα»α |
αααααααααα, αααΌααααααααΆαα ααααααααααααα, ααααα»αα§ααααΆα αααα | ααΆαααΆαα±ααααΆαααΆααααααααααΆααααααααα»αααααααααααΌαα ααααααα α»α (fault-current) αα·αααΆααααααααααα·ααα»α (loop-impedance)α |

ααααΎαααΎαααααααααααααα’ααααΎααααααααα ααααα αΆααααααΎαααααααααα»α αα·αα ααααααα α»ααααααΆααα αααα»αααααααΈα RCBO ααααααααααααα D α’αΆα αααααααΆααααα αΆααΆαααΆααααααΆα αααααα·αα αΆαααΆα ααααα»ααααα αΆααααααΎαααααΎαααΆα ααα»ααααααΆααα’αΆα αααααΆααααααΆααααααααΆαααα α»αααααα ααααα·αααΎααΆααααααααααααΈαααααααα α αΎαα ααααααααααΆααααααααΈααααΈααΆαααααα·αααΆααααα.
αααααΆααααΆααααααααααα’α·ααααααα ααΌαααΎαα’ααααααααα VIOX ααααΈααΈ ααΆααααααΉαα’αααΈαααααααααααΎααααΎα.
ααα αΆαααΈ 6α ααααΎαααΎαααΆαααααααα ααΆαααααααααααΌα (Pole Configuration) αα·αααΆααααα αααααααΊα (Neutral Arrangement)
ααΆααααααα αααααααααΆααα αααα»αααααααΈαααααααΌαααΆαααΆα ααααΌαααααααααΆααααααααααα αΆαααααααΆα αααααααααα (residual-current sensing system) αααα RCBOα ααΆααααααΆααααααααΊααα·αααααΉαααααΌα ααΊααΆααΌαα ααα»ααΌαα αααα»ααα½αααααΆαααΆααααααΆα αααααα·αααΆαααααα.
| ααΆαααααααα ααΆαααααααα | ααΆαααααΎααααΆααααααααΆα | α’αααΈαααααααΌααααααααααΆαα |
|---|---|---|
| RCBO αααααα 1P+N | ααααααΈα α»ααααααααααααααααααααΎαα αααΆααααα½α (Single-phase final circuits) | ααΎααααα’ααααΆααααΉα (Neutral) ααααΌαααΆαααΆααααααΆα α α¬αααααΆααααΆααααΆαα·α αα α αΎαααΎαααΌαααααααααΎαααΆαααΆαααΆαααΆαααΎαα αααααααα¬αα |
| α§αααααααΆαααΆα RCBO αααααα 2P | ααααααΈααααΎαααααΆααααΆααααα½α (Single-phase) αααααααΌαααΆαααΆααααααΆα αααΆααααααααααΎα αα·αααααα’ααααΆααααΉα | ααΎαααΌαααΆααααΈαααααΌαααΆαααΆααααααΆα αα¬α’αα αα·αααααααααΆαα’αα»ααααααΆαααΆαααΆαααΎαα αααα |
| α§αααααααΆαααΆα RCBO αααααα 3P | ααααααΈααααΎαααΈααααΆααααΆα (Three-phase) αααααααΆαααααα’ααααΆααααΉα | ααααααααΎαααΆααααΈααααΆααααΆαααααααΆααα§αααααααα |
| α§αααααααΆαααΆα RCBO αααααα 3P+N α¬ 4P | ααααααΈααΈα αααΆααααααΆαααααααΊα (Neutral) | ααααααΊαααααΌαααααααααΆααα§αααααα αΆαααααααΆα ααααααα ααααΆα (Residual-current sensor) α αΎαα’αα»ααααααΆαααΆαααααΆαααααα’αααααα·α |

ααΆαααααααααααα’αααααα·αα’αΆα
ααΆαααΆααα»αααααΆα. 1P+N α’αΆα
ααΆααααααΆααΆαααΌαααααα‘αΆααααααΆαααΆαααΆαααΆααα½αααΆαα½αααααααΊααααααΆααα»αααΆαα, ααααΌαααααααΊαααΆα
ααααα‘αα, α¬ααΆααααα
αααααααααα’αΆαααααααΎααΆααα
ααΆα ααααΌααααααααααααΆααααααΆααααΆαααααααααΎα, αααααΆαααααΆαααα
α
ααα»α
αααααΆαα, ααΆααααααααααααααααΊα αα·ααααααΉααα·ααααααααα·αααααΆαα·α
αα
α.
α αααΆααααααΆααααααΆααααααααΊα
αα»αααααΎααααααΊααα½αααααΆαααΆαααααααΈ RCBO ααααα ααΆααααααα ααααα·αααΎααααα‘αΆαααααααααΈαα½ααααα‘αααααα·αααΆααααααααααΊαααααααααΈαα½αααα RCBO ααΉαααΎαααΎαα’αα»αααααΆαα ααααα αΎαααΉαααΆα αααααΎαα αααα»αααααΈα’αΆαααααααΆαααα ααΆαααΆαα‘αααααααΊαα’αΆα αααααΎαααααααααααααααααΆαα±αααααα ααα‘α αα·αααΆαααααα·ααααΆααα»αα’αααΈαα»ααααα·ααΆααααα»ααααααααΆαα.
ααα αΆαααΈ 7α αα·αα·ααααααααααΆαααΆααα αααα (Breaking Capacity)
αααααααΆαααΆααααααΆα α (Breaking capacity) ααΊααΆα ααααααααααΆααααααααΈααααΈα’αα·ααααΆααα RCBO α’αΆα ααΆααααααΆα αααΆααααααααααααααααααααααααΆααααααα ααΆααΌαα ααΆααααΌαααΆααααααΆααααΆα―αααΆ kA ααΌα ααΆ 6 kA, 10 kA α¬ 16 kAα.
α αααΆααααΊααΆαααΆαα αααΆααααΆααα
αααααααΆαααΆααααααΆα
ααααα RCBO β₯ α
ααααααααααΆααααααααΈααααΈαααααααΉααα»ααα
α
ααα»α
ααα‘αΎα
α ααααααααααΆααααααααΈααααΈαααααααΉααα»ααα αα·αα αααα αΌαααΆααα α¬ααααααααααα’αΆα ααΆαααααα·ααααααααΆααα α α»ααααα ααααααααααΈα α»ααααααααααααα αααααΆααΌαα ααα»ααα RCBO ααααα·α 6 kA α’αΆα ααααΎααααΆααααΆααααα»αααΌααααΎααα½α ααα»αααααα·ααααααααααΆαααααααΆααααΌααααΎααα½ααααα.
αα ααααααααααα RCBO ααΌααα·αα·αααααΎαα
- αααααΆαααααΆαααααααααΆαααΆααααααΆα αααααααΈααααΈαααααΆαααααα
- ααααααααααααααα»ααααααΆαααααααααααΆαααααααααα
- αααααααΆαααα·ααααααααΆααααααα
- αααααΌαααΆαααΆαααΆαααααα»ααα»ααα αααααααΆαααΎ (upstream) α¬αααααΌαααΆααααααααααα½α
- ααΎααΈααΆααααα‘αΎαααΆαααααα·αααα α»α (fault level) αααααΆαααααΆ α¬ααΆααααααααα¬αα
αααααΆααααΆααααααααΆαααααααααααΎα ααα»α ααΆααααΆαα ααΌαααααΎααααΆαα VIOX ααααα»ααααααααααααααΆαααΆααααααΆα ααααα RCBO αααααΆααααΆαααααΎαααΎαααααα·α 6 kA, 10 kA αα·α 16 kA.
ααα αΆαααΈ 8α αα·αα·αααααΎααααααααΆα αα·ααααααΆαααααΆααααα·ααα
αααααΆααααΈααααΆααααααα’ααααΎαααααααΆα IEC, RCBO αααααΆααααααΎααααΆαααααα»αααα ααααΆα αα·ααααααα·ααΈααααααααααΆ ααΆααΌαα ααααΌαααΆαααααΆαααααΆααααΆαα½αααΉα IEC/EN 61009-1, αααααααααααααααΎα§αααααααΆααααααααΈαααααΆαα ααααααα ααααΆα (residual-current) ααΆαα½αααΉαααΆαααΆαααΆαααΎαα αααα (overcurrent) αα½ααααα αΌαααααΆα α§αααααααΆαααΆαα ααααααα ααααΆααααααα F αα·ααααααα B ααααααΌαααΆαααααΆαααααΆααααΆαα½αααΉα IEC 62423 αααα»αααααΈαααα’αΆα α’αα»ααααααΆαα.
αα»αααααΎαααΎαααα·ααααααααα’ααααΎα αααααΎααααα»αααΆααΆα‘α»ααααα½ααα»αα ααΌααα·αα·αααααΎαααΆααααααΆααααΆαααααααααΎααα·ααα αα·ααααααΉααα·αααααααα αα ααααααααααΆααα
- αααααααΆαααα
- ααα»α αα·αααααααααααααΆαααααα (Rated voltage and frequency)
- ααΆαααααααα αα α»αααααα
- ααααααα ααααααα
- α ααααααααα·ααααα·ααΆααααααααααααΆαααααα (Rated residual operating current)
- αααααααααΆαααααΎααααΎα
- αααααααΆαααααα
- ααΆαααααααα ααΆαααααααααααΌα
- ααααΆααααΆααααααΆααααααααααΎααα α ααα»α αααααΆαα (Terminal wiring diagram)
- ααΈαα»ααα ααΆαααααα·ααααα·ααΆα αα·αααααα·ααααααααααΆαααα‘αΎα
- αα·ααα αααααααααααΆα/αααααααα»α (Line/load) ααααα·αααΎααΆαααΆααααααΆαα
ααααα·αααΎαααααααααααΌαα±ααααΆααα·ααααΆααααααααΆαα·ααΆααααΆααααΆαα½α αα»ααααααααΆααΆααααααΆααααΆααααααααΆα IEC ααΊαααααααααΆαααααααα ααΌααααααααααΆααααΆαα’αα»αααααααααααΌααααααΈααααΆα αα·ααααααααα αα αααααααααααααα.
ααΆαααααΎαααΎα RCBO ααΆαααΆαααααΎααααΆαα
| αααααα·ααΈ | α ααα»α α αΆααααααΎαααΌαα | α’αααΈαααααααΌααα·αα·ααααα»ααααααααΎαααΎαα α»αααααα |
|---|---|---|
| ααααααΈααααΎαααααααΊ | αααααα A, 30 mA, ααααααα B α¬ C α’αΆαααααααΎα ααααα αΆααααααΎα (Inrush current) | ααΆαααα ααααΆαα αααααα·αα ααααα αΆααααααΎααααα LED driver, αααααααααααα·αααα»ααααα»α, ααΆααααα αααααα»αααααααΈ |
| ααααααΈααααΈααααΎαααΌαα | αααααα A, 30 mA, ααααααα B α¬ C | α§ααααααααααααΉαααΆααΉααααααΆαα ααΆααααααΌααααα»αα ααααααα ααααΆα αα·αααααα·αααα αααααααααΎα |
| ααααααΈαααααΆααααααααΆα α¬α§αααααααααΎααααΆαααααα»ααααα | αααααα A α¬αααααα F, 30 mA | ααΆαααααααααααααααααααααα’αα‘α·α ααααΌαα·α ααΆαα»αααα αα»αααααααα α¬α ααααα αΆααααααΎααααααααΌααα |
| ααααααΈαααααΆααααααααααΉα α¬ααΈααΆαααααααΆαααααΎα | 30 mA α¬ααααααα 10 mA ααΆαααΆααααααααΆααααΆαα | αααααααααααα·ααααΆααααααΆααααααααααΎααααα»ααααα»α α αΆαα·αααααααΆαααΆα αα ααααααααα·αα αΆαααΆα α αα·αααΆαααα ααααΆαα ααααααααα§ααααα |
| ααααααΈαααααΆααααααΎααααΆαααααα αααα | αααααα A, 30 mA ααΌαα | ααΆααααααΆααααΉαααααΎα, ααααααααΎαααα, α§αααααα ααα, ααΆαααΆαααΆααααααααΆααααα |
| αααΆαααΈαααΌαααααα α¬α§αααααααααΎααααΆαααααααα Inverter | αααααα F α¬ αααααα B αααα»αααααΈαααααΆαααΆααααααααΆααααΆαα | αααααΌαααΆαααααα’αααααα·α, ααΌαααΆααααααα ααααααα ααααΆα, ααααααααααΆαα αΆααααααΎαααααΎαααΆα |
| ααααααΈααΆααααααΆαααααα’αααα·αααΈ (EV) | αααααα B, αααααα A-EV, α¬αααααα A αααααΆααα»αααΆαα αΆαααααααΆ DC 6 mA α’αΆαααααααΎααΆααα ααΆ | αααααααΆαααααΆααααΆα, α§ααααα RDC-DD ααΆααααα»α, αααααααααααα·αααα»ααααα»α, ααΆααααααααααα½αααΆαα½α RCD αα αααααααΆαααΎααααααααΈ |
| αααααα ααααααααΆαα (AC) ααα’αΆααααΊααααααΆααααααααΊααααα’αΆαα·ααα (Solar PV) | αααααα A α¬ αααααα B α’αΆαααααααΎααΆααα ααΆ αα·αααΆαααααΆαααααα’αΆααααΊαααα | ααΆααααα½ααα·αα·αααα ααααααα ααααΆαααααα’αΆααααΊαααα, ααααααααααααΆααααααααααΌ (transformerless topology), αααααααααααα·αααα»ααααα»α |
| ααααααΈα ααα αΆαααΆααααααααααΆαααΎ (Upstream) | 100 mA α¬ 300 mA, ααΆααΏααααααΎαααααα selective/time-delayed ααΆααααααΌαααΆα | ααΆαααΆαααΆαα’ααααΈααα, ααΆααααααααααΆααααααΆαααΆα αα αααα (discrimination), αα·α RCBO 30 mA αα αααααααΆαααααα (downstream) |
ααΆααΆααααααΊααΆα ααα»α α αΆααααααΎαααα»ααααα αα·ααααααΆααΆααααα½αααααα ααααΆαααΆαααα‘αΎαααααα’αααααα·αα§ααααα α¬αααααααααααα·ααααααααΎααααα»ααααα»ααααααα.
ααα α»αααΌαα αααα»αααΆαααααΎαααΎα RCBO
ααα α»αααΈ α‘α ααΆαααααΎαααΎααααααα’ααααΎαααααΆααα’αααααααα½ααα»α
RCBO αααααΆααααααΆαααααΆαα 32 A αα·ααααααΆααααααΆααΆα’αΆα ααααΎααΆααααααααααααΈαααααΆααααααΆαα 32 A αααααα ααααααααα ααααααα ααααΆα (Residual-current type) ααααααα (Curve) αααααααΆαααΆααααααΆα α (Breaking capacity) ααααα·αααα»α αα·αααΆαααΆαααΆαααααα αααα αα»αααααααααΌαααααΆαααΆααααΈαααααΆααααααΆααΆαα½αααΉαααΆαααα‘αΎαα.
ααα α»αααΈ α’α ααΆαα αΆαααα»ααααααα AC ααΆα’αΆα ααααΎααΆααααααααΈαααααα
α§αααααααααΎααααΆα αααΎαααΆααααα»αααΌαα§ααααααααααααΌαα αααα (Rectifiers) ααααα (Filters) αα·αααΆαααααααααααααΆααααααααααΌα (Switching power supplies)α ααααα·αααΎα§αααααααΆαααααα’αΆα αααααΎαα αααα DC αααααΆαα ααααΆαα α¬α ααααααα ααααΆαααααααααααααα·ααααααΆααααααΈαα»α (Non-sinusoidal) ααααααααα AC α’αΆα ααΉααα·αααααααα‘αΎαα.
ααα α»αααΈ α£α ααΆαααααΎααααΆαααααααα B αααααααΈαααααα
αααααα B ααΆαααααααααΌααααΌααΆαααΆαααΆααα αα ααααα ααα»ααααααΆαα·ααααααΆαααααΎαααααα’αααα»αααΆαααααααααααααα·α αα α¬αα·ααααααααααααΆαααααααααααααΈαααααα ααΌαααααΎααΆαααααΆααααααααΈααααααααααααααα ααααααα ααααΆααααααΌαα±ααααααΎααα»ααααα ααΌα ααΆαααα»αααααΈααααααα’αααα·αααΈ (EV) ααααααααααΆααααααααΊααααα’αΆαα·ααα (PV) α§ααααα VFD α¬αααααα·ααΈα§ααααΆα αααααα½αα ααα½αα.
ααα α»αααΈ α€α ααΆααα·αα’αΎααΎααΉαα ααααααα ααααΆαααααααΆ
α§αααααα’αα‘α·α ααααΌαα·α ααααααααΎααααααΆαααααααααα α§αααααααΆαααΆαααΆαααΎαα‘αΎαααα»α (Surge protective devices) αα·αααααα (Filters) αα»αααααα’αΆα ααααα±ααααΆαα ααααααα ααααΆαααααααΆα ααααα·αααΎα§αααααααΆα αααΎαααααΌαααΆαααΆαααααα αΌαααααΆαα ααΎα§αααααααΆαααΆααααα½α α ααααααα ααααΆαααααααααΌααααα»αααααΆα’αΆα αααααΆαα±ααααΆαααΆαααΆααααααΆα αααααα·αα αΆαααΆα α αααααΈααΆαα·αααΆαααα α»ααααααααααΆααααααααααΆααααΆαα½αααΎαα‘αΎααααααα.
αααααΆααααΆααααα αααααΆαα ααααααα ααααΆα (leakage current) αα·αα ααααααααα (residual current) ααΌαααΎαααΆαααααΆααααα VIOX α ααααααα ααααΆα αααααΉα α αααααααααα αααααΉα α ααααα α»αααΈ.
ααα α»αααΈ α₯α ααΆαααααΎαααΎαααα α RCBO αααααααΎαααααΉαααααααααΎα
ααΆαααααΎαααΎαααα ααααααα’αΆα αα½αααΆαααΆαααΆαααΆα αα ααααααααα·αα αΆαααΆα α ααα»ααααααΆααα’αΆα αααΆααααααα»αααΆαααΆαααΆαααααααααΎαααΈααΆααααα»αααΎαααααα·ααααααα ααΌαααααΎα αααααα ααΆααααααααΈ αα·ααααααααΆααααα»αα ααααααααααααααααΎααααααΆααααααααΌαααΆααΌαααααΆαα.
ααα α»αααΈ α¦α ααΆαααααΎαααΎαααααααααααααα D αααααααΆαααΆααααααααααΆααα ααααααααααΆαα (fault-current)
α§αααααααααααααααααα D α’αΆα ααααΆααααααΉαα αααααααααααΆαααααααααΆα ααα»ααααααΆααΆαααΆαα±ααααΆαα ααααααααααΆαααααααααααΆαααααααΆααααΆαααΆααα ααααααααααααααααααΆαααα·αααααααααααααα·αααααΆαα ααααα·αααΎααΆααααααααααα·αα ααααααααααΆαα (fault loop impedance) αααααααα ααααααααααααα D α’αΆα ααΉααα·αααΆααα αααααα αααααΆααααα αΆααΌα ααΆαααααΉααα»ααααααα.
ααα α»αααΈ α§α ααΆαααΆααααα αΌαααααΆααααααααΊα (Neutrals)
ααααααΈ RCBO ααΈαα½ααααααΌααααααααΆααααααααΎα (line) αα·αααααααΊα (neutral) α±αααα ααΆαα½αααααΆα ααΆαααααΎααααααΊααα½αααααΆ ααΆαααα αΈααααααΊα α¬ααΆαααααΎαααΆαααΊαααααα·αααααααΉααααααααΆαααΆα ααΊααΆααΌαα ααα»ααΌαα αααααααΎα±αα RCBO ααΆα αα αααααααα»αα’αα‘α»ααααααΆααα±ααααααΎαααΆαα.
RCBO vs RCCB ααΌα MCB
αα·ααΈααΆαααααααΆααααΈαα’αΆα ααααΉαααααΌαα.
| ααΆααααα αααΈααΆαα (Layout) | αααααΆαα | αααααααα |
|---|---|---|
| RCCB + MCB α αααΎα | α ααα½αα§ααααααα·α ααΆααα»α αα·ααααααααααΆααα ααα αΆαααΆααααααααααΆααααααΆαα | ααΆαααα ααααΆαα ααααα’αααα·αααΈαα½αα’αΆα ααααΎα±ααααΆα αααααααΈααΆα αααΎααααα»αααααααα½α |
| RCBO αααα»ααα½αααααααΈ | ααΆαααααΎαααΎαααααααΈααΆαααα’αααααΎα αα·αααΆααααααααΈααΆααααα α»αααΆααααααΆααααα½α | α ααα½αα§αααααα αααΎαααΆααα»α αα·αααΆααααα ααααα Neutral αααααΆααααααααααααΆα |
ααααΎαααΎα RCBO αα ααααααααΆααα ααΆααααΌαααΆαααΆαααααααααΆαααααΆαααααααααΎα ααΆαααΆαααΆαααααααΈααΆα ααααα‘αα ααΆααααααααΆααααα αΆααΆααααααΆααααα½α α¬ααΆαααΆαααΆααα½ααααα αΌαααααΆαααααΆαααα αααΌα α ααααΎαααΎα RCCB ααΌααα½αααΉα MCB αα αααααααααααααα αα ααααααααααααα αα ααΆααααααααα αααΆα α¬ααααΆααααααααααααΆααα ααα αΆαααΆαααααααααΆαααΆαααΆαα ααααααα ααααΆαααΆαααα»αα.
αααααΈαααα½ααα·αα·ααααααααααα αα αααααα α»αααααααααααΆαα RCBO
αα»ααααααααΎααΆααααααΆαα·α ααΌααααααΆααααααααΆααααα’α·αααΆαααααα
- αααααα RCBOα AC, A, F, B α¬αααααΌαααΆααα·ααααααααΆαα EV/PV
- ααααα·αααΆααααααααα½α (Sensitivity)α 10 mA, 30 mA, 100 mA, 300 mA α¬αααααααΆααααΆααααΆααααααα
- α ααααααααα (Rated current)α ααααΌαααααΆααΆαα½αααααα»α αα·ααααααααΆααααα»αα ααααααααααααααααΎα
- αααααααααΆααααααΆα α (Trip curve)α B, C α¬ D
- αααααααΆαααΆααααααΆα α (Breaking capacity)α ααααΎααΉα α¬αααααααΆαα ααααααααΆααααααΈ (Short-circuit current) αααα’αΆα ααΎαααΆα
- α ααα½ααααΌα (Poles)α 1P+N, 2P, 3P, 3P+N α¬ 4P ααΆααααααΌαααΆα
- ααΆααααα αααααααΊα (Neutral arrangement)α ααααααΊαααΆααα»αααΆααααΆααααααΆα α, ααααααΊααααααΆααααααΆαα α¬ααΆααα ααΆααΆααααΆααααΆααααα»αα αα»αααα·α
- ααα»α αα·αααααααααααααΆαααααα (Rated voltage and frequency)
- αααααΌαααΆααααααααΆα αα·ααα·ααααΆαααααα
- ααΆαααααααΆααα ααα»α αααααΆααααΆαα½ααααααααααααΆαααααΆαα (Busbar) ααααΌα’αααα·αααΈ
- αα·ααα ααααααααααΎαα αΌα/α αα αα·αααααΆααααΆααααααΆαα
- ααΆααααααΌααααα»αααα ααααααα ααααΆα αα·αααΆαααααΎαααΎαααααΆααααααΆαααΆααααααΆα α (Selectivity) αααΆαα§αααααααΆαααΎ αα·αααΆαααααα
αααααΆααααΆαααΆααααααααα·ααα αα·αααΆαααααΎαααΎααααΌααα ααΌααααααααααα·ααααααααααΆαααα‘αΎαααΆαα½αααΉααααααΉααα·αααααααα αα ααααα (Datasheet) ααΆααααααααααα RCBOα ααα»ααααααααα, α αααααααα»αααααααΈ, ααααα·αααααααααΎα, ααααα·αααααα α»α (Fault level), ααααααααααα»α αα·ααααααΌαααΆααααααααααααα·αααα»αααΌαααααΆαα ααααα·αααΎα’ααααααα»αααΆααααααΌα’αααα·αααΈ α¬αααααααααααααααααΆαααααααα OEM ααΌααα·αα·αααααΎα αα½αααα·ααα RCBO αααα VIOX αααααΉααααααΈαααα½ααα·αα·αααααΆαααααΎαααΎαααΆαααΎα.
αααα½ααααα½αααΉαααΆαα
ααΎαααααα RCBO αα½αααΆαααααα’αααα»ααααααΆααααααααΈα’αααα·αααΈααααααααΎα?
αααααΆααααααααΈα α»ααααααααααααααααα’αααα·αααΈααααααααΎαααΆα αααΎα αααααα A ααΆααΏααααΆα ααα»α α αΆααααααΎααααααΆαααααααααΆααααααα AC ααΈαααααααΆα’αΆα α αΆαααααααΆα ααααααα ααααΆααααααα DC αααααΆαα ααααΆαα (Pulsating DC) ααααΌα ααΆα ααααααα ααααΆααααααα AC ααααααΈαα»α (Sinusoidal AC)α αααααΆαααΆαααΆααααα αααααα F α¬αααααα B α’αΆα ααΉαααααΌαααΆααααααΆααα§ααααααααααααΎααααΆαα Inverter, ααααΆααααΆαααααααα’αααα·αααΈ (EV chargers), Inverter αααααΆααααααααααααΌα‘αΆ (PV inverters) α¬ααααα»ααααααααααααα’αΆα αααααΎααααααααααααα ααααααα ααααΆααα»ααααααΆα.
ααΎ RCBO αααααα A ααα’ααΆααααααα AC αααα¬?
αααααα A α’αΆα α αΆαααααααΆαααα ααααααα ααααΆαααΆαα αααΎαααΆααααααα AC ααΌα ααααααΆααΆααΌαα αααααα·ααααΆααααααΆααααααααΈαααααΆαααααα»αααΆααααΏαα’αα‘α·α ααααΌαα·αα ααααα·ααααααΆααααααΆααΆααααααααΈααΆααα’αααα»αααααααααΌαααΆααααααα A αααααααααααααααα·ααααα ααα»αααααααααα AC αα·ααα½αααααΌαααΆαααααΎααααΆαααααα»αααααΈαααααααα»α α¬αααααααααααα·αααα»ααααα»ααααααΌαα±ααααααΎαααααα A, F α¬ B αααααα.
ααΎαααα»ααα½αααααΎαααΎα RCBO ααααα·α 10 mA α¬ 30 mA?
ααααα·α 30 mA ααααΌαααΆαααααΎααααΆαααααΆαααΌααααΌααΆααααααΆααααΆαααΆαααΆαααααααααααα»αααααα ααΎααααααΈα α»ααααααα ααααα·α 10 mA αααααααΌαααΆααααααααα½ααααααααΆα ααα»ααααααΆαααΉαααΆα αααααΎααααααααΆαααΌαα ααα»α αααΆααααΆαα ααΌα ααααααΆααΆααΌαα ααααΌαααΆααααααΆαα»ααααααΆαααααααα·ααΈαααααΆαα αΆαα·αααααααααα·ααα α¬ααΆαααΆαααΆααααα»αααααααααααΆααα ααΆα’αα»ααααΆαα±ααααααΎααααααα.
ααΎα’αααΈααΆααΆααα»αααααΆαααΆα RCBO ααααα·α 30 mA αα·α 300 mA?
RCBO ααααα·α 30 mA ααααΌαααΆαααααΎααΆααΌαα αααααΆααααΆαααΆαααΆαααΆααααα’αααα·αααΈααααα»αααααα ααΎααααααΈα α»ααααααα α§αααααααααα·α 300 mA ααΆααΌαα ααααΌαααΆαααααΎαααααΆααααααααααααΆαααΆααα αααααααΆαααΎ (Upstream) ααΆαααΆαααΆαα’αααα·ααα α¬αα»αααααΆαααααααΆαααΆααααααααΎαααΎα α αΎααα·ααα½αααααΌαααΆαα αΆαααα»αααΆααΆα§ααααααααα½ααααααααΆαααααααΆααααααααΈα α»ααααααααααααααΌαα±ααααΆαααααα·α 30 mA αααααα.
ααΎαααα»ααα½αααααΎ RCBO ααααααααααααα B α¬αααααα C?
ααααΎααααααααααααα B αααααΆααααααααΈαααααΆαα ααααα αΆααααααΎαααΆα ααΌα ααΆααααΎαααααααΊααΆαα αααΎα α¬ααααα»ααααααααααααααΆα (Resistive loads)α ααααΎααααααααααααα C αααααΆααααααααΈαααααΆαα ααααα αΆααααααΎαααααα ααΌα ααΆααααααΈααααΈααααΎαααΌαα α¬αααΌαααααΌα αα ααΆαααααΎαααΎαα α»αααααααα ααααααΌααααααααααΆααααααΌαααΆαααααΆααααααααΆαααα α»αααααα.
ααΎ RCBO ααααααααααααα D ααααΌαααΆαααααΎααααΆαααα αααααΆ?
RCBO ααααααααααααα D ααααΌαααΆαααααΎαααααΆααααααα»ααααααΆαα ααααα αΆααααααΎαααααα (High-inrush loads) ααΌα ααΆαααααααααΌ α¬αααΌααααααα ααΆαα½αααααααΌαααΆαααααΎαααΎαααααΎααααΆαα αα»αααααΆααααΆααα·αα·ααααααααΆααααΆ α ααααααααααΆααααα α»α (Fault current) ααΆαααααα·αααααααααααααααΆαα ααΎααααΈααΆααααααΆα αα§αααααααΆαααααΉαααααΌααααα»αααααααααααααα ααααααααΈ (Short-circuit)α.
ααΎ RCBO αα½αααΆααααααααΆαααΆααααααΆα αα αααα (Breaking capacity) ααααα·αααΆ?
αααααααΆαααΆααααααΆα αα αααααααα RCBO ααααΌαααααααΎ α¬ααααΆαα ααααααααααΆααααααΈαααααααΉααα»α (Prospective short-circuit current) αα α ααα»α ααα‘αΎαα αααααααΌαα αα½αααΆα 6 kA, 10 kA αα·α 16 kA ααα»ααααααΆαααααΎαααΎαααααΉαααααΌαααΊα’αΆαααααααΎααααα·αααα α»αααΆαααααααα.
ααΎαααα»αα’αΆα αααα½α MCB ααΆαα½α RCBO ααΆααα?
ααΆααΉαααΆααααΊα’αΆα ααααΎααΆα ααααα·αααΎ RCBO αααααΆαααΆααααΈααααΆααΉαααααα·αα ααααααααααααΈ, ααααααα, αααααααΆαααΆααααααΆα αα αααα, ααα»α, ααΆαααααααα ααΆαααααααααααΌα, αααααααα Busbar αα·ααααααΌαααΆαααΆαααΆαα ααααααα ααααΆαα ααΆαα·ααααααΆααΆααααα½ααααααααΆαααααααααΆαααααααααΌαααααα αα»αααααΆααααΆααααααα·αααΆαααααα αα·αααααααΆααααα’α·αααααΆααααααΆααααααααααΎαααΆαααΆαααΌα ααααΆα.
α ααα»α’αααΈααΆαααΆ RCBO ααΆααααααΆα αα αααααααααααΆαααα α»αααΆααααααα?
ααΌαα ααα»ααΌαα αα½αααΆα ααΆααααααΌααααα»αα ααααααα ααααΆα, ααααΎα, ααΆαΰΉΰΈͺΰΈ·ΰΉΰΈΰΈ‘αα»αααΆαααα’ααΈααΌα‘αα, ααΆαααΆααααα αΌαααααΆααααααααΊα (Mixed neutrals), ααΆαααααΎααααΆααααααααΊααα½αααααΆ (Shared neutrals), α§αααααα’αααα·αααΈααΆααααα αΆ, ααΆαααα ααααΆαααΈ VFD α¬ααααα (Filter), ααΆαααα ααααΆαααΈα§αααααααΆαααΆαααΆαααΎαα‘αΎαααα»α (Surge protective device) α¬ααΆαααααΎααααΆαααααααα RCD αα·αααααΉαααααΌααααααΆααααααα»ααααα.
ααΎ RCBO ααΆαααΆααααααΆααααΉαααΆααααα’αααα·αααΈαααα¬αα?
RCBO α’αΆα αααααααΆαααΆαααΆαα ααααααα ααααΆα ααααα½αααΆαααααααα αΆαα·αααααααΆααααα’αααα·αααΈ αα ααααααα ααααααα ααααΆαα α»αααΈ α¬ααΆαααααΌαααααααααααααα·αααΆαααααααα»αα ααΆαα»αα’αΆα αα»αααααΆααααΆαααααααααααΆααααααΆααααααΆαααΆαααααα»αααααα ααΌα ααΆααααΈααα»αααααααΆαααααααααααααΎα (Line) αα·αααααα’ααααΆααααΉα (Neutral) αααα»αααααααα½α αααα αααααα ααααΆααα»αααααΆαα.
ααααα αα·αα―αααΆαααααα αα ααααα
- ααααα VIOX αααααΆαααααΆααααααΌαααΆααα·αα·αααα‘αΎααα·αα ααααααααΎαααΎα RCBO α±ααααΆαααααΉαααααΌα
- αααααΆαααααΌαα αα RCD αα·α RCBOα α§αααααααΆαααΆαα ααααααα ααααΆα (Residual-current device)
- IEC/EN 61009-1α α§αααααααΆααααααααΈααααΎαααΆααααα ααααααα ααααΆα αααααΆααα»αααΆαααΆαααΆαααΎαα αααααα½ααααα αΌαααααΆ αααααΆααααααΎααααΆαααααα»αααα ααααΆα αα·αααΆαααααΎααααΆααααααααααααΆ
- IEC 60755α αααααΌαααΆαααΌαα αααααΆααα§αααααααΆαααΆααααααααΎαααΆααααα ααααααα ααααΆα αα·αααααααααααααααα RCD
- IEC 62423α α§αααααααΆαααΆαα ααααααα ααααΆααααααα F αα·ααααααα B αααα»αααααΈαααα’αΆα α’αα»ααααααΆα