VIOX ELECTRIC
Γλώσσα
Direct Factory · Industrial LED Indicator Light & Pilot Lamp Manufacturer (26 Models)

LED Panel Indicator Lights & Flash Buzzers AD16-22DS, AD16-16DS, AD16-22SM Audible Buzzers & AD22-22/30 Pilot Lamps (12V–380V AC/DC)

Η VIOX Electric κατασκευάζει 26 industrial LED indicator lights and panel pilot lamps—covering universal Ø22 mm AD16-22DS standard & high-brightness 5-color LEDs, compact Ø16 mm AD16-16DS, flashing audible buzzers (AD16-22SM / AD22-22MFD / 30MFD), and Ø30 mm heavy switchgear pilot lights rated for ≥30,000 hours.

26 ModelsAD16 · AD22 · Flash Buzzers
Ø16 / 22 / 305 IEC Colors · High-Brightness
12V – 380VAC/DC · ≥30,000h LED Life
VIOX AD16-22DS and AD22 Industrial LED Panel Indicator Lights and Buzzers
01 · Complete Published Indicator Light Lineup (26 Models)

Browse VIOX AD16-22DS, AD16-16DS, AD16-22SM Buzzers & AD22 Pilot Lamps

Filter our stocked LED signaling lineup by series below, or compare Ø16 / Ø22 / Ø30 mm panel cutouts and voltage options in the engineering table.

Complete VIOX AD16 and AD22 LED indicator light, buzzer, and specialty pilot lamp matrix
Series / Models Panel Cutout Colors & Function Voltage Range (AC/DC) Product Pages
AD16-22DS (Standard & High-Brightness)Ø22 mmRed · Green · Yellow · Blue · White12V · 24V · 110V · 220V · 380VΚόκκινο · Πράσινο · Κίτρινο
AD16-16DS Compact IndicatorØ16 mm5 IEC Colors · Space-Saving Barrel12V · 24V · 110V · 220VView AD16-16DS →
AD16-22SM / AD22-22MFD / 22MFNØ22 mmFlashing LED + 80–85 dB Piezo Buzzer12V · 24V · 110V · 220VAD16-22SM · AD22-22MFD
AD22-22DS / 22AS / 22DRY / 22DSVØ22 mmStandard, Shallow Body & Dual-Color12V · 24V · 110V · 220V · 380VAD22-22DS · AD22-22DRY
AD22-30DS / 30AS / 30MFD / 30MSDØ30 mmLarge-Lens Pilot & Heavy Flash Buzzer24V · 110V · 220V · 380VAD22-30DS · AD22-30MFD
Specialty Automotive / Toggle LampsPanel / Dash12V Toggle Light & Shift Indicator12V / 24V DCToggle Light · Shift Light
02 · Interactive Cutout, Function & Voltage Matcher

Match the Exact AD16 / AD22 Indicator Light or Buzzer to Your Door

Select your panel cutout diameter, signaling function, and control voltage to confirm the exact VIOX part series.

1. Panel Cutout Diameter
2. Signaling Function
3. Control Circuit Voltage
03 · IEC 60204-1 Color Coding & Panel Cutout Standard

5-Color Industrial Pilot Lamp Meaning & Ø16 / Ø22 / Ø30 mm Cutouts

Standardize panel-door signaling across switchgear and machinery for global UL/IEC compliance.

IEC 60204-15 Standard Pilot Light Colors · Operator Status Reference
Ø16 mm · Ø22 mm · Ø30 mm Circular Punch
RED · Emergency Fault · Overload Trip Hazardous Condition YELLOW · Warning Abnormal · Pre-Alarm Approaching Limit GREEN · Normal Safe State · Ready Motor / Line Running BLUE · Mandatory Reset Required Operator Intervention WHITE · Neutral Mains Power Present General Confirmation

Pilot Lamps vs. Mimic Semaphores

Use Ø22 mm LED pilot lamps for run, trip, and mains status. For substation mimic diagrams requiring 3-state (On/Off/45° Error) breaker feedback even without aux power, pair with VIOX mechanical semaphore switch position indicators.

Anti-Interference Against Ghost Glow

Long parallel AC control runs can induce 20–60V capacitive leakage that causes cheap LEDs to glow dimly when OFF. Specify VIOX anti-interference AD16/AD22 modules for clean dark-off state.

2-in-1 Visual + Audible Alarms

Save a second cutout by installing AD16-22SM ή AD22-22MFD flashing buzzers—delivering simultaneous bright red LED strobing and 80–85 dB audible warning in one Ø22 mm hole.

04 · Series-Level Cross-Reference Benchmark

VIOX AD16 / AD22 Indicator Lights vs. Schneider, ABB & Siemens

Universal Ø22 mm and Ø30 mm panel footprint compatibility for switchgear OEMs and electrical distributors.

Comparison of VIOX AD16 and AD22 LED indicator lights against Schneider Harmony, ABB, and Siemens SIRIUS
Signaling Tier Schneider / Siemens ABB / CHINT VIOX Direct Equivalent Εμπορική και OEM διαφοροποίηση
Ø22 mm Monolithic LEDSchneider XB7EV / XB5AV · Siemens 3SU1ABB CL2 · CHINT ND16-22DSAD16-22DS · AD22-22DS (Std & High-Bright)50%–70% lower OEM BOM; 5 IEC colors stocked
Ø22 / Ø30 mm Flash BuzzerSchneider XB5KS · Acoustic BeaconCHINT ND16-22SMAD16-22SM · AD22-22MFD · AD22-30MFDCombined flash + 85 dB buzzer in 1 hole
Ø16 mm Compact & Dual-ColorSchneider XB6 · Compact PilotPanel Console Mini LEDAD16-16DS · AD22-22DRY Dual-ColorCustom voltage & laser-marked legends

Πού καταλήγει αυτό στην πράξη

If an oil-and-gas specification legally requires ATEX Zone 1 explosion-proof or sole-source Schneider Harmony XB4 metal bezels with zero alternates, stay with that line. For panel builders, machinery OEMs, and electrical distributors needing universal Ø16/Ø22/Ø30 mm LED pilot lamps and flash buzzers at 50%–70% BOM savings, VIOX delivers direct factory supply.

05 · Direct Factory Proof · LED Indicator Light Manufacturer

Quotation Variables, 100% Burn-In & Brightness QC & OEM Supply

Transparent factory cost drivers, 24-hour LED aging, color-bin consistency, and mixed-color distributor boxes.

4 specification variables that determine VIOX indicator light factory unit pricing
Μεταβλητή προσφοράς Standard Baseline Engineered / OEM Option Factory Quote Impact
1. Brightness & FunctionΠρότυπο AD16-22DS steady LEDHigh-brightness ≥100 cd/m², dual-color AD22-22DRY, or flash buzzer AD16-22SMPiezo buzzer & high-output SMD die add minor delta
2. Cutout & VoltageØ22 mm · 24V AC/DC or 220V ACØ16 mm / Ø30 mm, 380V AC, or anti-interference high-threshold driverEliminates ghost glow on long control cables
3. Lens & TerminalStandard PC lens & screw clampCustom laser-etched symbols (arrows, text) & IP65 silicone gasketFast visual identification on OEM control desks
4. OEM Packaging & Batch10 pcs/inner box · VIOX export cartonMixed 5-color distributor kits, EAN barcodes & private-label boxesSamples 3–5 business days · Batch production 7–15 days

1. 100% 24h LED Burn-In QC

Continuous thermal burn-in screens out early LED or resistor drift before lamps leave the assembly line.

2. Color-Bin Uniformity

Tight wavelength binning ensures Red, Green, Yellow, Blue, and White lenses match evenly across multi-panel doors.

3. 2000V Dielectric & dB Audit

Hi-pot insulation testing and 80–85 dB buzzer loudness checks verify reliable fault signaling in noisy plants.

Evaluation Samples5–10 pcs/color dispatched in 3–5 business days for brightness & panel-fit tests.
Mixed-Color MOQMix all 5 colors, voltages & buzzers from $1,000–$1,500 · Lead time 7–15 days.
Export & WarrantyEXW / FOB Ningbo or Shanghai · 2–3 year factory replacement warranty.
06 · Interactive B2B Tool · 5-Step Indicator Light RFQ Builder

Generate Your Indicator Light & Buzzer RFQ Brief in 30 Seconds

Select series/cutout, lens colors, control voltage, and OEM packaging—copy or send directly to VIOX engineering.

1. Series & Cutout Size
2. Lens Color Mix
3. Rated Voltage
4. Technical Option
5. Supply & Branding
07 · Panel Signaling & Control Knowledge Hub

Control Panel Signaling Guides & Companion Hubs

Engineering references authored by VIOX control-panel specialists.

08 · Technical & OEM Sourcing FAQ

Indicator Light Cutout, IEC Color & Buzzer Questions

Cutout Size What is the difference between AD16-22DS, AD16-16DS, and AD22-30DS indicator lights?

The number after the dash specifies the circular panel mounting hole diameter: AD16-16DS fits a compact Ø16 mm cutout, AD16-22DS and AD22-22DS fit the universal Ø22 mm industrial cutout, and AD22-30DS fits heavy-duty Ø30 mm switchgear doors.

Flash Buzzer When should I use an AD16-22SM or AD22-22MFD flashing indicator light with buzzer?

Use AD16-22SM (Ø22 mm) or AD22-30MFD (Ø30 mm) whenever an overload trip, emergency stop, or tank high-level alarm requires both intermittent visual flashing and an audible alert (≥80 dB) from a single panel cutout.

IEC Colors What do Red, Yellow, Green, Blue, and White panel indicator lights mean under IEC 60204-1?

Under IEC 60204-1: Red indicates Emergency / Fault / Hazardous state; Yellow (Amber) indicates Abnormal / Caution; Green indicates Safe / Normal Operation; Blue indicates Mandatory Operator Action; and White indicates Neutral / Power On.

Ghost Glow Why do some 220V AC LED pilot lights glow dimly when turned OFF, and how do I stop it?

Long parallel control cables induce capacitive leakage voltage (20–60V AC) that can faintly illuminate low-threshold LEDs. Specify VIOX anti-interference (high-threshold) AD16/AD22 LED indicators to eliminate ghost glowing completely.

Cross-Reference Are VIOX AD16-22DS and AD22 pilot lamps drop-in replacements for Schneider XB4/XB5/XB7 and ABB CL2?

Yes. Universal Ø22 mm circular cutouts, lock-nut clamping (1–6 mm panels), finger-safe screw terminals, and 12V–380V AC/DC ratings allow direct drop-in replacement at 50%–70% lower OEM BOM cost.

OEM & Supply What factory QC tests and OEM packaging options does VIOX offer for indicator lights?

Every batch undergoes 24-hour LED burn-in, luminous intensity & color-bin matching, 2000V dielectric withstand, and buzzer dB checks. OEM options include custom laser-etched legend symbols, mixed-color kits, and private-label boxes.

Direct Factory & Distributor Signaling Supply

Need AD16-22DS Pilot Lamps, AD16-22SM Buzzers or Mixed-Color Kits?

Share your cutout size, voltage, color mix, and monthly volume. VIOX factory sales will reply with sample dispatch details and wholesale pricing within 24 hours.

26 Stocked AD16 & AD22 Models 100% 24h LED Burn-In & Bin QC Mixed-Color Distributor Kits Ready