Surge Protective Device (SPD) Manufacturer 15 VIOX VSP Series · Type 1/2/3, 690V Wind, PV 2000VDC & Dedicated SCB
VIOX Electric manufactures 15 specialized VSP surge protection series—from graphite spark-gap Type 1 (VSP-X) and 25 kA Type 1+2 (VSP-T25/B+C, including 690 V/760 V wind) to ultra-slim VSP-40N, ultra-low-Up VSP-40GX, 600–2000 V DC Solar PV, built-in fuse VSP-RT, and coordinated VSP-SSD SCB backup disconnectors.
15 VIOX VSP Surge Protection & SCB Series
Filter by IEC protection class or DC solar rating. Each series page includes full pole ratings, wiring rules, and CAD dimensional drawings.
VIOX VSP-20 / VSP-40
AC Type 2 · 20kA / 40kA- Σειρά VIOX
- VSP-20 / VSP-40
- Ονομαστική τάση
- AC 275V / 320V / 385V / 440V
- Surge Rating
- In 10/20 kA · Imax 20/40 kA
- Πρότυπο
- IEC 61643-11 · TUV / CE / CB
VIOX VSP-60 / VSP-80 / VSP-100 / VSP-160
AC Type 2 · 60kA – 160kA- Σειρά VIOX
- VSP-60 / VSP-80 / VSP-100 / VSP-160
- Ονομαστική τάση
- AC 385V / 440V
- Surge Rating
- In 30–100 kA · Imax 60–160 kA
- Πρότυπο
- IEC 61643-11 · TUV / CE / CB
VIOX VSP-T15/B+C
AC Type 1+2+3 · 12.5kA Black- Σειρά VIOX
- VSP-T15/B+C
- Ονομαστική τάση
- AC 275V (L-N) / 255V (N-PE)
- Surge Rating
- Iimp 6.25 / 8 / 12.5 kA (10/350μs)
- Πρότυπο
- IEC 61643-11 · T1+T2+T3 · CE / CB
VIOX VSP-T25/B+C
AC Type 1+2 · 25kA Heavy Duty- Σειρά VIOX
- VSP-T25/B+C
- Ονομαστική τάση
- AC 275V / 350V / 440V
- Surge Rating
- Iimp 25 kA (10/350μs) · Imax 50 kA
- Πρότυπο
- IEC 61643-11 · T1+T2 · CE / CB
VIOX VSP-40/G600 – G2000
Solar PV DC Type 2 · 600V–2000V- Σειρά VIOX
- VSP-40/G600 – G2000
- Ονομαστική τάση
- 600V / 1000V / 1500V / 2000V DC
- Surge Rating
- In 20 kA · Imax 40 kA (8/20μs)
- Πρότυπο
- IEC 61643-31 · EN 50539-11 · TUV / CE
VIOX VSP-15T/G1000 / G1500
Solar PV DC Type 1+2 · 1000V / 1500V- Σειρά VIOX
- VSP-15T/G1000 / G1500
- Ονομαστική τάση
- 1000V DC / 1500V DC
- Surge Rating
- Iimp 6.25 kA (10/350μs) · Imax 40 kA
- Πρότυπο
- IEC 61643-31 · T1+T2 PV · CE / CB
VIOX VSP-SSD50X / VSP-SSD80 / VSP-SSD160
SPD Backup SCB · T1 & T2- Σειρά VIOX
- VSP-SSD50X / VSP-SSD80 / VSP-SSD160
- Ονομαστική τάση
- AC 440V (50/60 Hz)
- Surge Rating
- T1 Iimp 30kA · T2 Imax 80kA / 160kA
- Πρότυπο
- IEC 61643-11 Coordinated · CE / CB
VIOX VSP-T25/B+C (690V / 760V)
690V / 760V AC · Wind & Inverter- Σειρά VIOX
- VSP-T25/B+C (690V / 760V)
- Ονομαστική τάση
- AC 690V / 760V (IT / TN-C)
- Surge Rating
- Iimp 25 kA · Imax 50/120 kA
- Πρότυπο
- IEC 61643-11 · T1+T2 · 690V/760V
VIOX VSP-X15 / VSP-X30 / VSP-X50
AC Type 1 · Graphite 15–50kA- Σειρά VIOX
- VSP-X15 / VSP-X30 / VSP-X50
- Ονομαστική τάση
- AC 275V / 320V / 385V / 440V
- Surge Rating
- Iimp 15 / 30 / 50 kA (10/350μs)
- Πρότυπο
- IEC 61643-11 · Type 1 · 50kA Ifi
VIOX VSP-T25
AC Type 1 · 25kA Standard Gray- Σειρά VIOX
- VSP-T25
- Ονομαστική τάση
- AC 275V / 320V / 385V / 440V
- Surge Rating
- Iimp 25 kA (10/350μs) · In 25 kA
- Πρότυπο
- IEC 61643-11 · Type 1 · CE / CB
VIOX VSP-40N
Ultra-Slim · 18mm=2P / 36mm=4P- Σειρά VIOX
- VSP-40N
- Ονομαστική τάση
- AC 275V / 320V / 385V
- Surge Rating
- In 20 kA · Imax 40 kA (8/20μs)
- Πρότυπο
- IEC 61643-11 · TUV / CE / CB
VIOX VSP-10C
AC Type 3 · 10kA Fine Protection- Σειρά VIOX
- VSP-10C
- Ονομαστική τάση
- AC 385V (Un 220/230V)
- Surge Rating
- Uoc 10 kV (T3) · Up 1.5 kV
- Πρότυπο
- IEC 61643-11 · Type 3 · TUV / CE
VIOX VSP-40D / VSP-40E
18mm 1+NPE · Dual-Direction Wiring- Σειρά VIOX
- VSP-40D / VSP-40E
- Ονομαστική τάση
- AC 275V (L-N) / 255V (N-PE)
- Surge Rating
- In 20 kA · Imax 40 kA (8/20μs)
- Πρότυπο
- IEC 61643-11 · Type 2 · CE / CB
VIOX VSP-40GX
Ultra-Low Up · 0.8–1.2kV- Σειρά VIOX
- VSP-40GX
- Ονομαστική τάση
- AC 275V / 320V / 385V / 440V
- Surge Rating
- In 20 kA · Imax 40 kA (8/20μs)
- Πρότυπο
- IEC 61643-11 · Up ≤0.8kV · CE / CB
VIOX VSP-X15RT / VSP-20RT / VSP-80RT / VSP-100RT
Built-In Fuse · Rail & Industrial- Σειρά VIOX
- VSP-X15RT / VSP-20RT / VSP-80RT / VSP-100RT
- Ονομαστική τάση
- AC 275V / 320V / 385V / 440V
- Surge Rating
- T1+2 12.5kA · T2 40kA / 80kA / 100kA
- Πρότυπο
- IEC 61643-11 · Built-In Replaceable Fuse
Compare All 15 VSP Series by IEC Class & Waveform
Every AC, Solar PV DC, built-in fuse, and SCB backup disconnector mapped by waveform rating and direct datasheet link.
| VSP Series | IEC Class & Waveform | Key Surge & Voltage Rating | Best-Fit Engineering Role | Σελίδα προϊόντος |
|---|---|---|---|---|
| AC Type 1 & Type 1+2 Lightning Arresters (10/350µs Direct Lightning Zones) | ||||
| VSP-X15 / X30 / X50 | AC Type 1 (10/350µs) | Graphite Spark-Gap · Iimp 15/30/50 kA · Zero Leakage | Main service entrance with external LPS / heavy lightning exposure | View VSP-X → |
| VSP-T25 | AC Type 1 (10/350µs) | Pluggable Gray · Iimp 25 kA · Uc 275–440 V | Industrial main switchboards requiring pluggable Type 1 serviceability | View VSP-T25 → |
| VSP-T25/B+C | AC Type 1+2 (10/350 + 8/20) | Heavy-Duty Black · Iimp 25 kA · Imax 50 kA | Commercial & factory incomers combining direct lightning + surge clamping | View VSP-T25/B+C → |
| VSP-T25/B+C (690V/760V) | AC Type 1+2 High-Voltage | 690 V / 760 V AC · Iimp 25 kA · Imax 50/120 kA | Wind turbine converters, mining & 690 V industrial MCCs | View 690V/760V → |
| VSP-T15/B+C | AC Type 1+2+3 Combined | Iimp 6.25/8/12.5 kA · Uoc 20 kV · Up 1.25 kV | Compact commercial/residential main panels needing single-device T1+T2+T3 | View VSP-T15/B+C → |
| AC Type 2 & Type 3 Surge Protectors (8/20µs Distribution, Compact & Fine Clamping) | ||||
| VSP-20 / VSP-40 | AC Type 2 (8/20µs) | Pluggable · In 10/20 kA · Imax 20/40 kA | Standard sub-distribution boards, OEM panels & commercial feeders | View VSP-20/40 → |
| VSP-40N (Ultra-Slim) | AC Type 2 Compact | 40 kA in 18 mm 2P / 36 mm 4P (50% narrower) | Space-constrained DIN consumer units & dense automation cabinets | View VSP-40N → |
| VSP-40D / VSP-40E | AC Type 2 Dual-Mode Base | 18 mm 1+NPE · Mirrored N/PE terminals · 40 kA | Modular panel builds eliminating wire crossovers in compact boxes | View VSP-40D/40E → |
| VSP-40GX (Low-Up) | AC Type 2 Ultra-Low Up | Up 0.8–1.2 kV · In 20 kA · Imax 40 kA | PLC cabinets, CNC drives, servers & medical electronics | View VSP-40GX → |
| VSP-60 / 80 / 100 / 160 | AC Type 2 High-Capacity | Imax 60 kA – 160 kA · Uc 385/440 V | High-exposure industrial plants, telecom towers & overhead feeders | View VSP-60–160 → |
| VSP-10C | AC Type 3 Fine Protection | 18 mm 2P · Uoc 10 kV · Up 1.5 kV · Uc 385 V | Terminal-level fine protection directly upstream of sensitive instruments | View VSP-10C → |
| Solar PV DC Surge Protectors (IEC 61643-31 · 600V – 2000V DC) — Dedicated DC SPD Hub → | ||||
| VSP-15T/G1000 / G1500 | Solar PV DC Type 1+2 | 1000 V / 1500 V DC · Iimp 6.25 kA · Type Y 3P | Utility & C&I combiner boxes / inverters with external lightning rods | View VSP-15T PV → |
| VSP-40/G600–G2000 | Solar PV DC Type 2 | 600 / 1000 / 1500 / 2000 V DC · 40 kA (U/Y) | Rooftop, C&I, and next-gen 2000 V DC utility solar & BESS combiner boxes | View VSP-40 PV → |
| Built-In Fuse SPD & Dedicated SPD Backup Disconnector (SCB) | ||||
| VSP-RT Series | Built-In Replaceable Fuse SPD | VSP-X15RT/B+C · 20RT · 80RT / 100RT | Rail transit & unmanned cabinets with integrated internal replaceable fuse | View VSP-RT → |
| VSP-SSD50X / 80 / 160 | Dedicated SPD Backup (SCB) | T1 Iimp 30 kA (50X) · T2 Imax 80/160 kA | Passes lightning surges without nuisance trip; clears ≥3 A MOV faults | View VSP-SSD SCB → |
Match VSP Series, Pole Wiring & SCB Backup
Select your earthing system and lightning exposure zone to get the exact VSP series, pole topology, and coordinated VSP-SSD backup disconnector.
1. Power System & Earthing Architecture
2. Lightning Exposure / Protection Goal
10/350µs vs. 8/20µs Waveforms & Why SPDs Fail
Even a properly rated SPD fails in the field if installation leads exceed 0.5 meters or if backup protection nuisance-trips during a surge.
Rule 1 · TT & RCD Boards Require 3P+NPE (MOV + GDT)
A 4P MOV-only SPD on a TT grid leaks micro-amps to PE and risks sustained fault current if N-PE rises. Specify 3P+NPE (3+1) for galvanic N-PE isolation.
Rule 2 · Coordinate Backup With VSP-SSD SCB or VSP-RT
Standard MCBs nuisance-trip on lightning surges. Pair Type 1/T1+2 with VSP-SSD50X, Type 2 with VSP-SSD80/160—or use VSP-RT with an integrated replaceable fuse (Backup Protection Guide →).
Rule 3 · Cold-Site Voc Check for 600V–2000V Solar PV
PV string open-circuit voltage climbs in freezing weather. Ensure Ucpv ≥ 1.2 × Voc_STC using VSP-15T/G1000–G1500 (Type 1+2) or VSP-40/G600–G2000 (Type 2).
MOV Thermal Runaway
Aged varistors draw 3 A–10 A power-frequency leakage—too small to trip a 63 A backup breaker, yet hot enough to ignite the enclosure.
VSP-SSD SCB (≥3 A trip) or VSP-RT built-in fuse.Residual Voltage Exceeds PLC Limit
A 1.8 kV SPD plus 1 m of connecting wire delivers 2.8 kV to a 1.5 kV-rated PLC power supply—destroying electronics despite an intact SPD.
VSP-40GX (0.8–1.2 kV) and VSP-10C Type 3 fine protection.Zero DIN Space in Retrofits
Legacy distribution boards lack 4–8 modules of spare rail width for a separate SPD plus external backup disconnector.
VSP-40N fits 40 kA 2P in 18 mm (4P in 36 mm), or deploy all-in-one VSP-RT with built-in fuse.DC Arc Failure in 1500V–2000V PV
AC-rated MOV cartridges cannot extinguish sustained high-voltage DC fault arcs inside outdoor solar combiner boxes.
VSP-15T/G1500 και VSP-40/G600–G2000 (IEC 61643-31).VIOX VSP vs. DEHN, Phoenix Contact, ABB & Schneider
Drop-in 35 mm DIN-rail cross-reference for panel builders, solar EPCs, and distributors seeking direct factory BOM savings with full IEC 61643 compliance.
| Ρόλος Προστασίας | DEHN / Phoenix Contact | ABB / Schneider Electric | VIOX VSP Equivalent | Key Engineering Advantage |
|---|---|---|---|---|
| AC Type 1 Spark-Gap | DEHNventil M2 · Phoenix FLT-SEC-P-T1 | ABB OVR T1 · Schneider iPRD1 | VSP-X15 / X30 / X50 (Graphite Spark-Gap) | Zero standby leakage, 50 kA follow-current extinguishing |
| AC Type 1+2 (25kA / 12.5kA) | DEHNshield / DEHNventil · VAL-MS-T1/T2 | ABB OVR T1+2 · Schneider iQuick PRD | VSP-T25/B+C · VSP-T15/B+C (incl. 690V/760V) | Pluggable modules + dedicated 690V/760V wind/industrial option |
| AC Type 2 (20kA–40kA) | DEHNguard DG M TT/TNS · VAL-MS 230 | ABB OVR T2 40 · Schneider iPRD40r / iPF | VSP-20/40 · VSP-40N (Slim) · VSP-40GX (Low-Up) | Direct factory BOM savings; 18 mm 2P & 0.8 kV Low-Up options |
| Solar PV 600V–2000VDC | DEHNguard M YPV SCI · VAL-MS 1000/1500DC | ABB OVR PV T2 / T1-2 · Schneider iPRD-DC | VSP-15T/G1000–G1500 · VSP-40/G600–G2000 | Complete 600 V–2000 V DC coverage across T1+T2 and T2 |
| Dedicated Backup (SCB) | External gG fuse or SCB | Dedicated SPD backup module | VSP-SSD50X / 80 / 160 SCB · VSP-RT Built-In Fuse | Matched impulse coordination + space-saving built-in fuse |
Πού καταλήγει αυτό στην πράξη
If a utility or nuclear project legally mandates sole-source DEHN or Phoenix Contact with zero equivalents permitted, stay with that specified brand. Where IEC 61643-11 / 61643-31 performance governs—and you need full Type 1/2/3 + 2000 V DC PV + SCB backup coverage with direct OEM private-label supply—VIOX VSP is built to be your factory platform.
SPD Quotation Variables, 100% Factory QC & OEM Program
Direct manufacturing for electrical distributors, solar EPCs, and panel OEMs. Explore full factory capabilities on VIOX SPD Manufacturer →.
| Μεταβλητή προσφοράς | Standard Baseline | Engineered / Heavy-Duty Option | Factory Quote Impact |
|---|---|---|---|
| 1. Surge Technology & Rating | VSP-20/40 AC Type 2 (20 kA / 40 kA MOV) | VSP-X Graphite Spark-Gap Type 1, VSP-T25/B+C (25 kA Iimp), or VSP-160 | High-energy spark-gap / 34–40 mm MOV discs drive core unit cost |
| 2. Voltage & Pole Topology | 2P / 4P 275 V–385 V AC | 690 V/760 V Wind AC, 1500 V–2000 V DC Solar PV, or 3P+NPE GDT | Multi-stage DC arc-quenching & high-voltage GDT add delta |
| 3. Remote Signaling & Backup | Visual green/red status window only | FM dry-contact remote alarm (11/12/14) + VSP-SSD SCB or VSP-RT fuse | Modest add-on for SCADA monitoring & coordinated backup |
| 4. OEM Branding & Batch | VIOX standard catalog housing & carton | Custom laser/pad logo, private-label cartridge colors, custom carton & EAN | Mixed-series trial orders & OEM production quoted by BOM quantity |
100% U1mA & Leakage Screen
Every MOV varistor chip and finished plug-in cartridge is 100% screened for varistor voltage (U1mA) and micro-amp leakage current before assembly.
8/20µs & 10/350µs Impulse Lab
Batch-level surge impulse testing verifies In, Imax, Iimp, and residual clamping voltage Up across all 15 VIOX VSP series.
Thermal Disconnector Audit
Low-melting-point solder disconnectors and spring-loaded arc-cutoff mechanisms are thermal-aged to guarantee safe end-of-life isolation.
OEM Branding & One-PO Kitting
Custom front-panel laser branding, private-label cartons, and consolidated kitting with VIOX MCB, Θρυαλλίδα, και Προστατευτικά τάσης.
Generate Your VSP Surge Protection RFQ Brief
Configure series, earthing poles, SCB backup, remote alarm, and OEM scope to prefill our engineering quote form in one click.
1. Target VSP Series
2. Poles & Earthing
3. Backup Protection & Remote Alarm
4. Remote Signaling & OEM Branding
Technical Guides for SPD Selection & Panel Design
Deep-dive engineering references on SCB backup coordination, RCD placement, AC vs. DC PV safety, IEC 61643 standards, and multi-stage cascading.
SPD Backup Protection: Fuse, MCB, or SCB? How to Choose and Size
Διαβάστε τον οδηγό → Earthing & RCDShould an SPD Go Before or After the RCD? BS 7671 & TT 1+1 Trap
Διαβάστε τον οδηγό → AC vs. Solar PV DCAC SPD vs. DC SPD: Key Differences & Why They Are Not Interchangeable
Διαβάστε τον οδηγό → Cascading DesignSPD Coordination & Cascading Guide: 4 Engineering Verification Gates
Διαβάστε τον οδηγό → Πρότυπα IECIEC 61643 SPD Standards Explained: Part 01 vs. 11 vs. 21 vs. 31 vs. 41
Διαβάστε τον οδηγό → B2B ProcurementSPD Price Guide: Type, Voltage, kA Rating & Factory RFQ Factors
Διαβάστε τον οδηγό →VSP Surge Protector & SCB FAQ
Engineering answers on Type 1 vs. Type 2 waveforms, VSP-SSD SCB backup coordination, TT/TN-S earthing, 0.8 kV low-Up clamping, and 2000 V DC PV sizing.
IEC Classes When do I need a Type 1 (10/350µs) or Type 1+2 SPD instead of a standard Type 2 (8/20µs) SPD?
Install a Type 1 or Type 1+2 SPD (VSP-X15/X30/X50 graphite spark-gap, VSP-T25, VSP-T25/B+C, or VSP-T15/B+C) at the main service entrance whenever a building has an external lightning protection system (LPS) or overhead supply lines exposed to direct 10/350µs lightning currents.
Use Type 2 SPDs (VSP-20/40, VSP-40N, VSP-40GX, VSP-60–160) on sub-distribution boards for indirect switching and induced 8/20µs surges.
SCB Backup Why should I pair an SPD with a dedicated VSP-SSD SCB backup protector instead of a standard MCB?
Standard MCBs can nuisance-trip under high lightning impulse currents (leaving the board unprotected) or fail to clear small power-frequency fault currents (≥3 A) when an MOV ages.
VIOX VSP-SSD50X (for Type 1 / T1+T2, Iimp 30 kA) and VSP-SSD80 / SSD160 (for Type 2, Imax 80 / 160 kA) pass rated lightning impulses without tripping while instantly disconnecting ≥3 A power-frequency thermal faults.
Γείωση How do I choose between 3P, 4P, and 3P+NPE (3+1) SPD wiring for TN-C, TN-S, and TT systems?
Use 3P SPDs on TN-C (L1, L2, L3 + PEN). On TT systems and TN-S boards protected by upstream RCDs, specify a 3P+NPE (3+1) circuit using a gas discharge tube (GDT) between N and PE so zero leakage current flows to earth and upstream RCDs never nuisance-trip.
Low-Up / T3 What makes VSP-40GX (Up 0.8–1.2kV) and VSP-10C Type 3 different from standard Type 2 SPDs?
Standard 40 kA Type 2 SPDs clamp around 1.5–1.8 kV. Sensitive PLC power supplies, medical electronics, and CNC drives have 1.5 kV impulse withstand (Category I/II). VSP-40GX achieves ultra-low residual voltage (0.8–1.2 kV), while VSP-10C Type 3 (Uoc 10 kV) provides fine terminal clamping directly ahead of sensitive loads.
Solar PV DC How do I size Ucpv for 600V, 1000V, 1500V, and 2000V DC solar PV systems?
The SPD maximum continuous operating voltage (Ucpv) must exceed the string maximum open-circuit voltage corrected for coldest site temperature (Ucpv ≥ 1.2 × Voc_STC). VIOX VSP-15T/G1000–G1500 (Type 1+2) and VSP-40/G600–G2000 (Type 2) cover 600 V, 1000 V, 1500 V, and 2000 V DC arrays.
Συμβατότητα Are VIOX VSP series SPDs mechanically compatible with DEHN, Phoenix Contact, ABB, and Schneider panels?
Yes. All 15 VIOX VSP series mount on standard 35 mm EN 60715 DIN rails using 18 mm modular pitches (plus ultra-slim 18 mm 2P / 36 mm 4P in VSP-40N) with pluggable cartridges and optional FM remote signaling contacts for drop-in replacement and OEM supply.
Need Type 1+2, Solar PV 2000V DC or SCB Backup SPDs?
Share your rated voltage (AC/DC), earthing system, surge class, or Tier-1 part number for direct factory cross-reference, CAD drawings, and BOM pricing.
Request SPD Quote →