IEC 61643-11 & 61643-31 Direct SPD Manufacturer

Surge Protective Device (SPD) Manufacturer 15 VIOX VSP Series · Type 1/2/3, 690V Wind, PV 2000VDC & Dedicated SCB

VIOX Electric manufactures 15 specialized VSP surge protection series—from graphite spark-gap Type 1 (VSP-X) and 25 kA Type 1+2 (VSP-T25/B+C, including 690 V/760 V wind) to ultra-slim VSP-40N, ultra-low-Up VSP-40GX, 600–2000 V DC Solar PV, built-in fuse VSP-RT, and coordinated VSP-SSD SCB backup disconnectors.

15 VSP SeriesAC T1/T2/T3, Solar PV & SCB
25kA / 160kAIimp (10/350µs) · Imax (8/20µs)
Up to 2000V DC0.8 kV Low-Up · 690/760V Wind
VIOX VSP-20 / VSP-40 AC Type 2 Pluggable Surge Protection Device (20kA / 40kA)
02 · Engineering Comparison Matrix

Compare All 15 VSP Series by IEC Class & Waveform

Every AC, Solar PV DC, built-in fuse, and SCB backup disconnector mapped by waveform rating and direct datasheet link.

Complete 15-series VIOX VSP surge protective device and SCB backup disconnector lineup
VSP Series IEC Class & Waveform Key Surge & Voltage Rating Best-Fit Engineering Role Σελίδα προϊόντος
AC Type 1 & Type 1+2 Lightning Arresters (10/350µs Direct Lightning Zones)
VSP-X15 / X30 / X50 AC Type 1 (10/350µs) Graphite Spark-Gap · Iimp 15/30/50 kA · Zero Leakage Main service entrance with external LPS / heavy lightning exposure View VSP-X →
VSP-T25 AC Type 1 (10/350µs) Pluggable Gray · Iimp 25 kA · Uc 275–440 V Industrial main switchboards requiring pluggable Type 1 serviceability View VSP-T25 →
VSP-T25/B+C AC Type 1+2 (10/350 + 8/20) Heavy-Duty Black · Iimp 25 kA · Imax 50 kA Commercial & factory incomers combining direct lightning + surge clamping View VSP-T25/B+C →
VSP-T25/B+C (690V/760V) AC Type 1+2 High-Voltage 690 V / 760 V AC · Iimp 25 kA · Imax 50/120 kA Wind turbine converters, mining & 690 V industrial MCCs View 690V/760V →
VSP-T15/B+C AC Type 1+2+3 Combined Iimp 6.25/8/12.5 kA · Uoc 20 kV · Up 1.25 kV Compact commercial/residential main panels needing single-device T1+T2+T3 View VSP-T15/B+C →
AC Type 2 & Type 3 Surge Protectors (8/20µs Distribution, Compact & Fine Clamping)
VSP-20 / VSP-40 AC Type 2 (8/20µs) Pluggable · In 10/20 kA · Imax 20/40 kA Standard sub-distribution boards, OEM panels & commercial feeders View VSP-20/40 →
VSP-40N (Ultra-Slim) AC Type 2 Compact 40 kA in 18 mm 2P / 36 mm 4P (50% narrower) Space-constrained DIN consumer units & dense automation cabinets View VSP-40N →
VSP-40D / VSP-40E AC Type 2 Dual-Mode Base 18 mm 1+NPE · Mirrored N/PE terminals · 40 kA Modular panel builds eliminating wire crossovers in compact boxes View VSP-40D/40E →
VSP-40GX (Low-Up) AC Type 2 Ultra-Low Up Up 0.8–1.2 kV · In 20 kA · Imax 40 kA PLC cabinets, CNC drives, servers & medical electronics View VSP-40GX →
VSP-60 / 80 / 100 / 160 AC Type 2 High-Capacity Imax 60 kA – 160 kA · Uc 385/440 V High-exposure industrial plants, telecom towers & overhead feeders View VSP-60–160 →
VSP-10C AC Type 3 Fine Protection 18 mm 2P · Uoc 10 kV · Up 1.5 kV · Uc 385 V Terminal-level fine protection directly upstream of sensitive instruments View VSP-10C →
Solar PV DC Surge Protectors (IEC 61643-31 · 600V – 2000V DC) — Dedicated DC SPD Hub →
VSP-15T/G1000 / G1500 Solar PV DC Type 1+2 1000 V / 1500 V DC · Iimp 6.25 kA · Type Y 3P Utility & C&I combiner boxes / inverters with external lightning rods View VSP-15T PV →
VSP-40/G600–G2000 Solar PV DC Type 2 600 / 1000 / 1500 / 2000 V DC · 40 kA (U/Y) Rooftop, C&I, and next-gen 2000 V DC utility solar & BESS combiner boxes View VSP-40 PV →
Built-In Fuse SPD & Dedicated SPD Backup Disconnector (SCB)
VSP-RT Series Built-In Replaceable Fuse SPD VSP-X15RT/B+C · 20RT · 80RT / 100RT Rail transit & unmanned cabinets with integrated internal replaceable fuse View VSP-RT →
VSP-SSD50X / 80 / 160 Dedicated SPD Backup (SCB) T1 Iimp 30 kA (50X) · T2 Imax 80/160 kA Passes lightning surges without nuisance trip; clears ≥3 A MOV faults View VSP-SSD SCB →
03 · Interactive Engineering Selector

Match VSP Series, Pole Wiring & SCB Backup

Select your earthing system and lightning exposure zone to get the exact VSP series, pole topology, and coordinated VSP-SSD backup disconnector.

1. Power System & Earthing Architecture

2. Lightning Exposure / Protection Goal

04 · Coordination & Field Failure Modes

10/350µs vs. 8/20µs Waveforms & Why SPDs Fail

Even a properly rated SPD fails in the field if installation leads exceed 0.5 meters or if backup protection nuisance-trips during a surge.

IEC 61643 Waveform Energy & ≤0.5m Lead Inductance Rule Type 1 (10/350µs) ≈ 20× Energy of Type 2 10/350µs (VSP-X / T25) 8/20µs (VSP-40) Effective Clamping: Up + ΔU Every 1 m of wire adds ~1.0 kV inductive drop during 20 kA surge. Keep total L + PE lead ≤ 0.5 m Use Kelvin V-wiring or VSP-40GX SCB BACKUP COORDINATION (VSP-SSD50X · VSP-SSD80 · VSP-SSD160): VSP-SSD50X pairs with Type 1/T1+2 (30 kA Iimp); VSP-SSD80/160 pairs with Type 2 (80/160 kA Imax). Passes full lightning surge without nuisance trip, yet opens instantaneously on ≥3 A MOV fault current.

Rule 1 · TT & RCD Boards Require 3P+NPE (MOV + GDT)

A 4P MOV-only SPD on a TT grid leaks micro-amps to PE and risks sustained fault current if N-PE rises. Specify 3P+NPE (3+1) for galvanic N-PE isolation.

Rule 2 · Coordinate Backup With VSP-SSD SCB or VSP-RT

Standard MCBs nuisance-trip on lightning surges. Pair Type 1/T1+2 with VSP-SSD50X, Type 2 with VSP-SSD80/160—or use VSP-RT with an integrated replaceable fuse (Backup Protection Guide →).

Rule 3 · Cold-Site Voc Check for 600V–2000V Solar PV

PV string open-circuit voltage climbs in freezing weather. Ensure Ucpv ≥ 1.2 × Voc_STC using VSP-15T/G1000–G1500 (Type 1+2) or VSP-40/G600–G2000 (Type 2).

Failure Mode 01

MOV Thermal Runaway

Aged varistors draw 3 A–10 A power-frequency leakage—too small to trip a 63 A backup breaker, yet hot enough to ignite the enclosure.

VSP Fix: Low-temp thermal disconnector + mechanical flag + VSP-SSD SCB (≥3 A trip) or VSP-RT built-in fuse.
Failure Mode 02

Residual Voltage Exceeds PLC Limit

A 1.8 kV SPD plus 1 m of connecting wire delivers 2.8 kV to a 1.5 kV-rated PLC power supply—destroying electronics despite an intact SPD.

VSP Fix: Specify ultra-low-Up VSP-40GX (0.8–1.2 kV) and VSP-10C Type 3 fine protection.
Failure Mode 03

Zero DIN Space in Retrofits

Legacy distribution boards lack 4–8 modules of spare rail width for a separate SPD plus external backup disconnector.

VSP Fix: VSP-40N fits 40 kA 2P in 18 mm (4P in 36 mm), or deploy all-in-one VSP-RT with built-in fuse.
Failure Mode 04

DC Arc Failure in 1500V–2000V PV

AC-rated MOV cartridges cannot extinguish sustained high-voltage DC fault arcs inside outdoor solar combiner boxes.

VSP Fix: Dedicated DC arc-quenching VSP-15T/G1500 και VSP-40/G600–G2000 (IEC 61643-31).
05 · Series Cross-Reference

VIOX VSP vs. DEHN, Phoenix Contact, ABB & Schneider

Drop-in 35 mm DIN-rail cross-reference for panel builders, solar EPCs, and distributors seeking direct factory BOM savings with full IEC 61643 compliance.

Series-level cross-reference of VIOX VSP SPDs against DEHN, Phoenix Contact, ABB, and Schneider Electric
Ρόλος Προστασίας DEHN / Phoenix Contact ABB / Schneider Electric VIOX VSP Equivalent Key Engineering Advantage
AC Type 1 Spark-Gap DEHNventil M2 · Phoenix FLT-SEC-P-T1 ABB OVR T1 · Schneider iPRD1 VSP-X15 / X30 / X50 (Graphite Spark-Gap) Zero standby leakage, 50 kA follow-current extinguishing
AC Type 1+2 (25kA / 12.5kA) DEHNshield / DEHNventil · VAL-MS-T1/T2 ABB OVR T1+2 · Schneider iQuick PRD VSP-T25/B+C · VSP-T15/B+C (incl. 690V/760V) Pluggable modules + dedicated 690V/760V wind/industrial option
AC Type 2 (20kA–40kA) DEHNguard DG M TT/TNS · VAL-MS 230 ABB OVR T2 40 · Schneider iPRD40r / iPF VSP-20/40 · VSP-40N (Slim) · VSP-40GX (Low-Up) Direct factory BOM savings; 18 mm 2P & 0.8 kV Low-Up options
Solar PV 600V–2000VDC DEHNguard M YPV SCI · VAL-MS 1000/1500DC ABB OVR PV T2 / T1-2 · Schneider iPRD-DC VSP-15T/G1000–G1500 · VSP-40/G600–G2000 Complete 600 V–2000 V DC coverage across T1+T2 and T2
Dedicated Backup (SCB) External gG fuse or SCB Dedicated SPD backup module VSP-SSD50X / 80 / 160 SCB · VSP-RT Built-In Fuse Matched impulse coordination + space-saving built-in fuse

Πού καταλήγει αυτό στην πράξη

If a utility or nuclear project legally mandates sole-source DEHN or Phoenix Contact with zero equivalents permitted, stay with that specified brand. Where IEC 61643-11 / 61643-31 performance governs—and you need full Type 1/2/3 + 2000 V DC PV + SCB backup coverage with direct OEM private-label supply—VIOX VSP is built to be your factory platform.

06 · Direct Factory Proof & OEM Supply

SPD Quotation Variables, 100% Factory QC & OEM Program

Direct manufacturing for electrical distributors, solar EPCs, and panel OEMs. Explore full factory capabilities on VIOX SPD Manufacturer →.

4 specification and OEM variables that determine VIOX VSP factory unit pricing
Μεταβλητή προσφοράς Standard Baseline Engineered / Heavy-Duty Option Factory Quote Impact
1. Surge Technology & Rating VSP-20/40 AC Type 2 (20 kA / 40 kA MOV) VSP-X Graphite Spark-Gap Type 1, VSP-T25/B+C (25 kA Iimp), or VSP-160 High-energy spark-gap / 34–40 mm MOV discs drive core unit cost
2. Voltage & Pole Topology 2P / 4P 275 V–385 V AC 690 V/760 V Wind AC, 1500 V–2000 V DC Solar PV, or 3P+NPE GDT Multi-stage DC arc-quenching & high-voltage GDT add delta
3. Remote Signaling & Backup Visual green/red status window only FM dry-contact remote alarm (11/12/14) + VSP-SSD SCB or VSP-RT fuse Modest add-on for SCADA monitoring & coordinated backup
4. OEM Branding & Batch VIOX standard catalog housing & carton Custom laser/pad logo, private-label cartridge colors, custom carton & EAN Mixed-series trial orders & OEM production quoted by BOM quantity
VIOX QC 01

100% U1mA & Leakage Screen

Every MOV varistor chip and finished plug-in cartridge is 100% screened for varistor voltage (U1mA) and micro-amp leakage current before assembly.

VIOX QC 02

8/20µs & 10/350µs Impulse Lab

Batch-level surge impulse testing verifies In, Imax, Iimp, and residual clamping voltage Up across all 15 VIOX VSP series.

VIOX QC 03

Thermal Disconnector Audit

Low-melting-point solder disconnectors and spring-loaded arc-cutoff mechanisms are thermal-aged to guarantee safe end-of-life isolation.

VIOX QC 04

OEM Branding & One-PO Kitting

Custom front-panel laser branding, private-label cartons, and consolidated kitting with VIOX MCB, Θρυαλλίδα, και Προστατευτικά τάσης.

07 · Factory Quotation Builder

Generate Your VSP Surge Protection RFQ Brief

Configure series, earthing poles, SCB backup, remote alarm, and OEM scope to prefill our engineering quote form in one click.

1. Target VSP Series

2. Poles & Earthing

3. Backup Protection & Remote Alarm

4. Remote Signaling & OEM Branding

VSP Surge Protector & SCB FAQ

Engineering answers on Type 1 vs. Type 2 waveforms, VSP-SSD SCB backup coordination, TT/TN-S earthing, 0.8 kV low-Up clamping, and 2000 V DC PV sizing.

IEC Classes When do I need a Type 1 (10/350µs) or Type 1+2 SPD instead of a standard Type 2 (8/20µs) SPD?

Install a Type 1 or Type 1+2 SPD (VSP-X15/X30/X50 graphite spark-gap, VSP-T25, VSP-T25/B+C, or VSP-T15/B+C) at the main service entrance whenever a building has an external lightning protection system (LPS) or overhead supply lines exposed to direct 10/350µs lightning currents.

Use Type 2 SPDs (VSP-20/40, VSP-40N, VSP-40GX, VSP-60–160) on sub-distribution boards for indirect switching and induced 8/20µs surges.

SCB Backup Why should I pair an SPD with a dedicated VSP-SSD SCB backup protector instead of a standard MCB?

Standard MCBs can nuisance-trip under high lightning impulse currents (leaving the board unprotected) or fail to clear small power-frequency fault currents (≥3 A) when an MOV ages.

VIOX VSP-SSD50X (for Type 1 / T1+T2, Iimp 30 kA) and VSP-SSD80 / SSD160 (for Type 2, Imax 80 / 160 kA) pass rated lightning impulses without tripping while instantly disconnecting ≥3 A power-frequency thermal faults.

Γείωση How do I choose between 3P, 4P, and 3P+NPE (3+1) SPD wiring for TN-C, TN-S, and TT systems?

Use 3P SPDs on TN-C (L1, L2, L3 + PEN). On TT systems and TN-S boards protected by upstream RCDs, specify a 3P+NPE (3+1) circuit using a gas discharge tube (GDT) between N and PE so zero leakage current flows to earth and upstream RCDs never nuisance-trip.

Low-Up / T3 What makes VSP-40GX (Up 0.8–1.2kV) and VSP-10C Type 3 different from standard Type 2 SPDs?

Standard 40 kA Type 2 SPDs clamp around 1.5–1.8 kV. Sensitive PLC power supplies, medical electronics, and CNC drives have 1.5 kV impulse withstand (Category I/II). VSP-40GX achieves ultra-low residual voltage (0.8–1.2 kV), while VSP-10C Type 3 (Uoc 10 kV) provides fine terminal clamping directly ahead of sensitive loads.

Solar PV DC How do I size Ucpv for 600V, 1000V, 1500V, and 2000V DC solar PV systems?

The SPD maximum continuous operating voltage (Ucpv) must exceed the string maximum open-circuit voltage corrected for coldest site temperature (Ucpv ≥ 1.2 × Voc_STC). VIOX VSP-15T/G1000–G1500 (Type 1+2) and VSP-40/G600–G2000 (Type 2) cover 600 V, 1000 V, 1500 V, and 2000 V DC arrays.

Συμβατότητα Are VIOX VSP series SPDs mechanically compatible with DEHN, Phoenix Contact, ABB, and Schneider panels?

Yes. All 15 VIOX VSP series mount on standard 35 mm EN 60715 DIN rails using 18 mm modular pitches (plus ultra-slim 18 mm 2P / 36 mm 4P in VSP-40N) with pluggable cartridges and optional FM remote signaling contacts for drop-in replacement and OEM supply.

Direct Factory Support

Need Type 1+2, Solar PV 2000V DC or SCB Backup SPDs?

Share your rated voltage (AC/DC), earthing system, surge class, or Tier-1 part number for direct factory cross-reference, CAD drawings, and BOM pricing.

Request SPD Quote →
15 VIOX VSP Series Ready AC Type 1/2/3, 690V/760V Wind, 600–2000V DC Solar PV & VSP-SSD SCB
IEC 61643-11 & 61643-31 Verified 100% U1mA & leakage screening with 10/350µs and 8/20µs impulse validation
OEM Branding & One-PO Kitting Private-label laser marking, custom cartons & consolidated switchgear export