Semaphore Indicators (Switch Position Indicators) GSY-SP Mechanical 3-State Disc & GSY-SP-L LED · Ø25 / 25×25 / Ø32 / 36×36 mm · AC/DC 24–240V
VIOX Electric manufactures mechanical disc (GSY-SP / -1) and dual-color LED (GSY-SP-L) semaphore switch position indicators for power-plant and substation mimic panels—10 datasheet configurations across Ø20 / Ø26 mm circular cutouts, Wiring Method I & II, και AC/DC 24–240V.
Browse & Compare All VIOX GSY-SP Mechanical Disc & LED Indicators
Filter by display mechanism below, or review exact bezel dimensions, Ø20 / Ø26 mm circular cutouts, Wiring Method I/II, and AC/DC operating voltage bands in the datasheet matrix.
GSY-SP25R / SP25R-1 Round
Disc · 3-State (Bar / -1)- Bezel
- Ø25 mm Round
- Cutout
- Ø20 mm Hole (≤10 mm)
- Καλωδίωση
- Method I or II
- Τάση
- AC/DC 24–240V
GSY-SP25S / SP25S-1 Square
Disc · 3-State (Bar / -1)- Bezel
- 25 × 25 mm Square
- Cutout
- Ø20 mm Hole (≤10 mm)
- Καλωδίωση
- Method I or II
- Τάση
- AC/DC 24–240V
GSY-SP32R / SP32R-1 Round
Large Disc · 3-State- Bezel
- Ø32 mm Round
- Cutout
- Ø26 mm Hole (≤10 mm)
- Καλωδίωση
- Method I or II
- Τάση
- AC/DC 24–240V
GSY-SP36S / SP36S-1 Square
Large Disc · 3-State- Bezel
- 36 × 36 mm Square
- Cutout
- Ø26 mm Hole (≤10 mm)
- Καλωδίωση
- Method I or II
- Τάση
- AC/DC 24–240V
GSY-SP25R-L Round LED
LED · 2-State (Green/Red)- Bezel
- Ø25 mm Round
- Cutout
- Ø20 mm Hole (≤10 mm)
- Καλωδίωση
- Method I or II (L00/01)
- Τάση
- AC/DC 24–240V
GSY-SP25S-L Square LED
LED · 2-State (Green/Red)- Bezel
- 25 × 25 mm Square
- Cutout
- Ø20 mm Hole (≤10 mm)
- Καλωδίωση
- Method I or II (L00/01)
- Τάση
- AC/DC 24–240V
| Κωδικός μοντέλου | Display Type & States | Bezel Size | Panel Cutout | Μέθοδος καλωδίωσης | Operating Voltage (AC/DC) | Σελίδα προϊόντος |
|---|---|---|---|---|---|---|
| GSY-SP25R | Disc · 3-State Bar (Off / On / 45° Error) | Round · Ø25 mm | Ø20 mm | Type I or II | 24–36 · 48–60 · 100–127 · 200–240V | GS-SP25R → |
| GSY-SP25S | Disc · 3-State Bar (Off / On / 45° Error) | Square · 25×25 mm | Ø20 mm | Type I or II | 24–36 · 48–60 · 100–127 · 200–240V | GS-SP25S → |
| GSY-SP32R | Disc · 3-State Bar (Off / On / 45° Error) | Round · Ø32 mm | Ø26 mm | Type I or II | 24–36 · 48–60 · 100–127 · 200–240V | GS-SP32R → |
| GSY-SP36S | Disc · 3-State Bar (Off / On / 45° Error) | Square · 36×36 mm | Ø26 mm | Type I or II | 24–36 · 48–60 · 100–127 · 200–240V | GS-SP36S → |
| GSY-SP25R-1 | Disc -1 · Three-Spoke Mimic (3-State) | Round · Ø25 mm | Ø20 mm | Type I or II | 24–36 · 48–60 · 100–127 · 200–240V | GS-SP25R → |
| GSY-SP25S-1 | Disc -1 · Three-Spoke Mimic (3-State) | Square · 25×25 mm | Ø20 mm | Type I or II | 24–36 · 48–60 · 100–127 · 200–240V | GS-SP25S → |
| GSY-SP32R-1 | Disc -1 · Three-Spoke Mimic (3-State) | Round · Ø32 mm | Ø26 mm | Type I or II | 24–36 · 48–60 · 100–127 · 200–240V | GS-SP32R → |
| GSY-SP36S-1 | Disc -1 · Three-Spoke Mimic (3-State) | Square · 36×36 mm | Ø26 mm | Type I or II | 24–36 · 48–60 · 100–127 · 200–240V | GS-SP36S → |
| GSY-SP25R-L | LED · 2-State (Green On / Red Off) | Round · Ø25 mm | Ø20 mm | Type I or II | 24–36 · 48–60 · 100–127 · 200–240V | GS-SP25R-L → |
| GSY-SP25S-L | LED · 2-State (Green On / Red Off) | Square · 25×25 mm | Ø20 mm | Type I or II | 24–36 · 48–60 · 100–127 · 200–240V | GS-SP25S-L → |
Build Your Exact Factory Order Code & Preview Live Panel State
Follow VIOX official 8-part encoding rule (e.g. GSY SP 25R II L00 DC100-127V) to lock bezel size, Ø20/Ø26 mm cutout, Wiring Method I/II, faceplate style, and operating voltage.
GSY-SP Terminal Mapping, Panel Cutouts & Parallel-Load Wiring Rules
Exact terminal assignments and mechanical envelope from the VIOX GSY-SP factory drawing. Safety guide: Reducing Misinterpretation Risks →.
Wiring Method I vs. Method II
Never mix them on site: Method I is for dedicated auxiliary contacts (cannot share parallel loads); Method II adds internal isolation so you can wire pilot lamps or relays in parallel on the same contact.
Ø20 mm & Ø26 mm Circular Cutouts
Even square bezels (25S 25×25 mm and 36S 36×36 mm) mount through simple round holes—Ø20 mm και Ø26 mm respectively—cutting CNC punching time on switchgear doors up to 10 mm thick.
Mechanical 3-State vs. LED 2-State
Choose mechanical disc (SP ή -1 three-spoke) when operators need unmistakable 45° fault/no-power detection in sunlight; choose SP-L LED for dark control rooms, or pair with LED pilot indicator lights for control panels for general run/trip alarms.
VIOX GSY-SP Semaphore Indicators vs. Mauell, EAO & ABB Mimic
Direct mimic-panel footprint and circular-cutout compatibility for MV/LV switchgear builders and substation EPCs.
| Mimic Panel Requirement | Mauell / EAO | ABB / Siemens / Rishabh | VIOX GSY-SP Direct | Εμπορική και OEM διαφοροποίηση |
|---|---|---|---|---|
| 25 mm Mosaic Tile (Ø20 mm Cutout) | Mauell 24×24 / 25×25 · EAO Mimic | Standard 25 mm Mimic Indicator | GSY-SP25R · SP25S · SP25R-L · SP25S-L | 45%–65% lower BOM cost; Disc & LED in one Ø20 mm cutout |
| Large Switchgear Door (Ø26 mm Cutout) | 36×36 mm High-Vis Semaphore | ABB / Siemens Cubicle Semaphore | GSY-SP32R · SP36S (+ -1 Three-Spoke) | AC/DC 24–240V wide-band coils stocked for substations |
| Parallel Load & Custom Faceplate | Special-order burden modules | Fixed catalog finishes only | Built-In Wiring Method II · Standard & -1 Faceplates | Order directly via 8-part GSY-SP encoding rule |
Πού καταλήγει αυτό στην πράξη
If a national grid utility tender legally mandates sole-source German Mauell mosaic tiles with zero equivalents, stay with Mauell. For MV/LV switchgear builders, substation EPCs, and control-desk OEMs needing Ø20/Ø26 mm round cutouts, Method I/II wiring, mechanical 3-state or LED 2-state displays, and 45%–65% BOM savings, VIOX GSY-SP is engineered for direct factory supply.
Quotation Variables, 100% Angle & Hi-Pot QC & OEM Supply
Transparent factory cost drivers, 3-state angle verification, Method II parallel-burden testing, and switchgear panel kitting.
| Μεταβλητή προσφοράς | Standard Baseline | Engineered / Utility Option | Factory Quote Impact |
|---|---|---|---|
| 1. Bezel & Cutout | GSY-SP25R / 25S (Ø20 mm cutout) | GSY-SP32R / 36S (Ø26 mm cutout) | Larger bezel frame & rotor add minor delta |
| 2. Wiring Method | Μέθοδος I (Standalone circuit) | Μέθοδος II (Parallel load permitted) | Specify I or II at RFQ to avoid rewiring delays |
| 3. Faceplate Mechanism | Mechanical Disc (SP standard bar or -1 three-spoke) | LED Indication (SP-L 00 default or reversed color) | Both fit the identical Ø20 mm panel cutout |
| 4. Operating Voltage & Batch | AC/DC 100–127V or 200–240V | AC/DC 24–36V / 48–60V + OEM private-label box | Samples 3–5 business days · Batch production 12–20 days |
1. 100% 3-State Angle QC
Every mechanical unit is energized on terminals 1–2, 1–3, and de-energized to verify crisp Off / On / 45° Error alignment.
2. Type I / II Burden Verification
Method II batches are verified under parallel pilot-lamp burden to ensure zero false deflection or coil chatter.
3. 2000V Dielectric Hi-Pot
Coil-to-bezel dielectric withstand checks guarantee operator safety on front switchgear doors (up to 10 mm panel).
4. Switchgear Panel Kitting
Consolidate GSY-SP semaphores with VIOX MCB, NH/RT18 Fuses, και DIN Sockets on one PO.
Generate Your GSY-SP Semaphore Indicator RFQ Brief in 30 Seconds
Lock bezel cutout, Method I/II wiring, display mechanism, and AC/DC coil voltage—copy or attach directly to VIOX engineering.
Semaphore Indicator Engineering, Cutout & Safety Guides
Technical references authored by VIOX switchgear signaling specialists.
What Is a Semaphore Indicator? Complete Switchgear Guide
How mechanical 3-state mimic indicators display breaker open, closed, and fault status.
Explore Guide →Ενδεικτική Σηματοφόρος έναντι Φωτεινής Στήλης: Ποια Συσκευή Σήματος Χρειάζεστε;
Compare substation mimic panel indicators against factory floor tower stack lights.
Explore Guide →How to Install Switch Position Indicators on Switchgear Doors
Ø20 mm & Ø26 mm panel cutouts, rear body clearance, and 3-terminal wiring verification.
Explore Guide →Δείκτες θέσης διακόπτη: Κλειδί για τη μείωση των κινδύνων παρερμηνείας
Why 45° error-state mechanical flags prevent catastrophic switching errors in substations.
Explore Guide →Enhancing Operational Safety & Efficiency With Switch Position Indicators
Integrating VIOX GSY-SP mimic indicators into MV/LV control panels and utility desks.
Explore Guide →Industrial HRC Fuses, MCBs & DIN Rail Switchgear Components
Consolidate GSY-SP semaphores with VIOX NH/RT18 fuses, MCBs, and DIN sockets on 1 PO.
Explore Guide →Frequently Asked Questions About GSY-SP Semaphore Indicators
Disc vs LED What is the difference between VIOX GSY-SP mechanical disc and GSY-SP-L LED semaphore indicators?
Mechanical disc models (GSY-SP25R/25S/32R/36S and -1 three-spoke versions) show three distinct contact states on substation mimic diagrams: Off (horizontal), On (vertical), and Error/Disabled (45° diagonal)—staying readable even if auxiliary power fails.
LED models (GSY-SP25R-L and GSY-SP25S-L) provide two high-brightness states for dim control rooms: Green for energized (On) and Red for de-energized (Off).
Panel Cutouts What are the exact panel cutout holes for GSY-SP25R, GSY-SP25S, GSY-SP32R, and GSY-SP36S?
All GSY-SP indicators use a circular mounting hole behind the front bezel: GSY-SP25R (Ø25 mm round) and GSY-SP25S (25×25 mm square) both require an Ø20 mm panel cutout. GSY-SP32R (Ø32 mm round) and GSY-SP36S (36×36 mm square) both require an Ø26 mm panel cutout.
Rear body depth is 130 mm, rear housing diameter is 20.5 ± 0.3 mm, and maximum panel thickness is 10 mm.
Wiring I vs II When must I specify Wiring Method I vs. Wiring Method II on VIOX GSY-SP orders?
Wiring Method I (Common Type) cannot be connected in parallel with other loads on the same auxiliary circuit. Wiring Method II is engineered specifically to operate in parallel with external burdens such as pilot lamps or relays—always specify Type I or Type II in your GSY-SP part code before production.
Voltages What operating voltages do VIOX GSY-SP switch position indicators support?
All 10 GSY-SP and GSY-SP-L models support four wide-range AC/DC auxiliary control voltages: 24–36V AC/DC, 48–60V AC/DC, 100–127V AC/DC, and 200–240V AC/DC (220–240V AC/DC).
Part Decoding How do I decode a VIOX GSY-SP part number such as GSY SP 25R II Ls01 DC100-127V?
GSY is the enterprise code, SP denotes Switch Position Indicator, 25R/25S/32R/36S specifies the bezel dimension, I or II sets the external wiring method (standalone vs. parallel load), L denotes LED faceplate (omitted for mechanical disc), 00/01 defines LED terminal color mapping, AC/DC voltage specifies operating power, and -1 selects the three-spoke mimic faceplate.
Συμβατότητα Are VIOX GSY-SP semaphore indicators compatible with Mauell, EAO, and ABB/Siemens mimic panels?
Yes. Standard 25×25 mm and 36×36 mm square bezels (with Ø20 mm and Ø26 mm round cutouts, max 10 mm panel thickness) fit substation mimic boards and MV/LV switchgear doors at 45%–65% lower BOM cost than European mimic brands.
Need GSY-SP25R / SP25S / SP36S Samples, CAD Drawings or EPC Pricing?
Share your bezel size, Method I/II wiring requirement, faceplate style, and auxiliary voltage. VIOX factory sales will reply with sample dispatch details within 24 hours.