⎯⎯ Low-Voltage Distribution · ACB
ACB for Low-Voltage Distribution Systems
VIOX ACB air circuit breaker solutions are built for switchboards, generator systems, industrial plants, and large commercial power distribution projects that require higher current handling, intelligent protection, and stable operating performance. The W1-2000 series product scope covers 630A to 6300A with fixed and draw-out configurations, 3P and 4P options, and intelligent trip unit support.
630A-6300A
Κάλυψη Ρεύματος
3
Frame Sizes
2
Τύποι τοποθέτησης
⎯⎯ W1-2000 Series
Intelligent Air Circuit Breaker
Suitable for main incoming protection, bus coupler switching, and higher-capacity feeder protection in low-voltage power distribution.
2000A
Frame for 630A to 2000A
4000A
Frame for 2500A to 4000A
6300A
Frame for 4000A to 6300A
3P / 4P
Fixed or draw-out construction
- 630A to 6300A Coverage
- Fixed and Draw-out Types
- 3P and 4P Structure
- Intelligent Trip Units
- Switchboard Integration Fit
⎯⎯ Επισκόπηση
What Is an ACB?
An ACB, or air circuit breaker, is a low-voltage circuit breaker that uses air as the arc extinguishing medium when the contacts open under load or fault conditions. It is commonly used in higher-current power distribution systems where main incoming protection, bus coupler switching, selective coordination, and service accessibility are more important than compact breaker size.
Air as the Breaking Medium
The breaker interrupts current and extinguishes the switching arc in air, which makes ACB products suitable for low-voltage systems with higher current demand.
Main Distribution Protection
ACB products are often used as main incoming breakers, bus coupler breakers, or high-current feeder breakers inside switchboards and distribution assemblies.
High-Current Low-Voltage Use
Compared with smaller breaker platforms, ACB products are better suited to applications that need higher current coverage, service access, and more advanced protection control.
⎯⎯ Product Range
Combiner Box Models and Categories
Explore real κουτί συνδυασμού, ηλιακό κουτί συνδυαστή, και Κουτί συνένωσης DC model groups by voltage class, string configuration, enclosure direction, and internal protection layout.
Frame Platform
2000A Frame ACB
Suitable for current ratings from 630A to 2000A in low-voltage switchboards, main panels, and higher-capacity feeder positions.
- Current Band: 630A - 2000A
- Pole : 3P / 4P
- Type: Fixed / Draw-out
Frame Platform
4000A Frame ACB
Designed for larger industrial and commercial distribution assemblies where higher current capacity and stable switching are required.
- Current Band: 2500A-4000A
- Pole : 3P / 4P
- AApplication : Main Incomer / Feeder
Frame Platform
6300A Frame ACB
- Current Band: 4000A-6300A
- Pole : 3P / 4P
- Use : High-Capacity Main Panels
Εγκατάσταση
Σταθερού τύπου ACB
Used where stable breaker mounting and straightforward integration into the panel structure are preferred.
- Mounting : Direct Panel Integration
- Benefit : Stable Mechanical Layout
- Fit : Standard Switchboards
Εγκατάσταση
ACB Τύπου Draw-out
- Mounting : Withdrawable Structure
- Benefit : Maintenance Convenience
- Fit : Service-Oriented Switchgear
⎯⎯ Technical Specs
ACB Technical Direction
ACB selection is usually confirmed by frame size, current band, installation type, voltage level, pole structure, interrupting requirement, and intelligent controller level. These factors help match the breaker to the real switchboard duty.
| Στοιχείο | Typical Coverage |
|---|---|
| Σειρά | W1-2000 Intelligent Air Circuit Breaker |
| Ονομαστικό ρεύμα | 630A to 6300A |
| Μέγεθος Πλαισίου | 2000A / 4000A / 6300A |
| Τύπος εγκατάστασης | Fixed Type / Draw-out Type |
| Επιλογές πόλου | 3P / 4P |
| Τάση συστήματος | Typical low-voltage applications at 415V / 690V |
| Συχνότητα | 50Hz / 60Hz |
| Μονάδα ταξιδιού | M / H / 3M / 3H intelligent controller options |
| Πεδίο προστασίας | Overload, short circuit, undervoltage, ground fault logic |
| Accessory Scope | Motor charging, shunt release, undervoltage release, auxiliary contact |
Configuration Highlights
ACB selection is usually confirmed by frame size, current band, installation type, voltage level, pole structure, interrupting requirement, and intelligent controller level. These factors help match the breaker to the real switchboard duty.
Switchboard Structure
Suitable for higher-current incoming distribution positions.
600V / 1000V
Fixed or draw-out mounting according to service workflow.
Accessory Expansion
Motor charging and release options for panel control logic.
Intelligent Monitoring
Προστασία συστοιχίας
⎯⎯ Εφαρμογές
Περιοχές εφαρμογής
ACB products are usually selected where current level, switching duty, and selectivity requirement go beyond compact low-voltage breaker platforms.
Main Switchboards
Used as main incoming breakers in low-voltage switchboards for commercial buildings, industrial plants, and utility rooms.
Bus Coupler Sections
Suitable for sectionalizing and coupling duties where dependable switching and isolation logic are important.
Generator Systems
Used for generator outgoing protection and other applications where higher current and control coordination matter.
Industrial Distribution
Fits factories, process plants, production workshops, and load centers requiring higher-capacity feeder protection.
⎯⎯ Selection Focus
Why This ACB Layout Works
The page follows the main factors normally used when reviewing ACB products for quotation, comparison, and switchboard matching.
Frame and Current Logic First
The page starts with 2000A, 4000A, and 6300A frame logic because current coverage is usually the first step in ACB selection.
Installation Type is Separated Clearly
Fixed and draw-out types are presented as distinct choices so maintenance strategy and switchboard design are easier to compare.
Trip Unit and Accessories are Included
Many ACB decisions depend on controller level and accessory logic, so those points are kept in the main comparison flow instead of being hidden.
RFQ Path is Kept Simple
The page closes with the exact project details that are most useful for ACB quotation, helping the buyer move from product review to inquiry faster.
⎯⎯ ΣΥΧΝΈΣ ΕΡΩΤΉΣΕΙΣ
Frequently Asked Questions About Cable Tie Products
What is an ACB used for?
An ACB air circuit breaker is used in low-voltage distribution systems as a main incoming breaker, bus coupler breaker, or higher-current feeder breaker. It is commonly selected for switchboards, generator systems, industrial plants, and large commercial power assemblies.
What current range does the VIOX ACB product scope cover?
The VIOX ACB product scope covers current ratings from 630A to 6300A across 2000A, 4000A, and 6300A frame sizes, which helps organize the range for different low-voltage distribution capacities.
How do I choose between fixed type and draw-out type ACB?
Fixed type ACB is commonly used for stable panel integration, while draw-out type ACB is generally preferred when service access, isolation during maintenance, and easier breaker replacement are important in the switchgear workflow.
What trip unit options are common on ACB products?
ACB products commonly include different intelligent controller levels such as M, H, 3M, and 3H options. The right choice depends on the required protection functions, operating display, monitoring depth, and communication needs.
What information is useful for an ACB quotation?
For a faster quotation, send the rated current, frame size, number of poles, fixed or draw-out preference, working voltage, accessory requirements, application, and target quantity. This helps match the correct ACB configuration more efficiently.
⎯⎯ Αίτημα Προσφοράς
Discuss the Right ACB Configuration
VIOX supports ACB product selection for low-voltage switchboards, generator systems, industrial distribution panels, and higher-current incoming or feeder applications. Share your project basics and we can match the frame size, installation type, pole structure, and accessory set more efficiently.
- 630A to 6300A current matching
- Fixed or draw-out structure confirmation
- Trip unit and accessory requirement review