Mechanical Dial Timer Switches SUL181d / SUL181h / SUL180a DIN-Rail & TB388 / TB35 / TB118N Wall-Mount with 100–300h Reserve
VIOX Electric fertigt 14 mechanical 24-hour & 7-day dial timer switches—spanning SUL181d / SUL181h / SUL180a / SUL160a / SUL189s DIN-rail models, heavy-duty TB388 / TB35 / TB38N / TB118N / TB330 wall timers, and outdoor/plug-in units with 100–300 hour quartz NiMH battery reserve.
Browse & Compare All 14 VIOX SUL DIN-Rail, TB Wall & Plug-In Mechanical Timers
Filter by installation format below, or compare quartz battery reserve, DIN module width, and pin resolution in the summary matrix.
Mechanische Zeitschaltuhr SUL181d
Flagship · 3M Quartz- Mount
- 35mm DIN (3M · 52.5mm)
- Antrieb
- Quartz · 150–200h Reserve
- Dial Step
- 24h · 15-min (96 Pins)
- Am besten geeignet für
- Panels, Pumps & Lights
Mechanische Zeitschaltuhr SUL181h
7-Day Weekly · Quartz- Mount
- 35mm DIN (3M · 52.5mm)
- Antrieb
- Quartz · 150–200h Reserve
- Dial Step
- 7-Day · 2-Hour Pins
- Am besten geeignet für
- Commercial Weekly HVAC
SUL180a Ultra-Slim DIN Timer
18mm 1M · Ultra-Slim- Mount
- 35mm DIN (1M · 18mm)
- Antrieb
- Synchronous (50/60Hz)
- Dial Step
- 24h · 15-min Segments
- Am besten geeignet für
- Compact Consumer Units
Mechanische Zeitschaltuhr SUL180A
1M DIN · Standard- Mount
- 35mm DIN (1M · 18mm)
- Antrieb
- Synchronous / Quartz Opt.
- Dial Step
- 24h · 15-min Segments
- Am besten geeignet für
- Tight Distribution Boards
SUL160a Mechanical Timer
Compact DIN · 24h- Mount
- 35mm DIN Rail (1M–2M)
- Antrieb
- Quartz / Sync Options
- Dial Step
- 24h · ON/AUTO/OFF
- Am besten geeignet für
- Lighting & Control Boxes
Mechanical Timer Switch SUL189s
3M DIN · Heavy Duty- Mount
- 35mm DIN Rail (3M)
- Antrieb
- Quartz / Sync Options
- Dial Step
- 24h · Captive Pins
- Am besten geeignet für
- Industrial Switchboards
Mechanische Zeitschaltuhr TB388
Flagship · Wall Quartz- Mount
- Wall / Panel Mount
- Antrieb
- Quartz · 100–300h Reserve
- Dial Step
- 24h · 15-min · 15A–20A
- Am besten geeignet für
- Boilers, Pumps & Signs
Mechanische Zeitschaltuhr TB35
Wall Mount · Quartz- Mount
- Wall / Panel Mount
- Antrieb
- Quartz Battery Reserve
- Dial Step
- 24h · Clear Dust Cover
- Am besten geeignet für
- Water Heaters & HVAC
Mechanische Zeitschaltuhr TB38N
Wall Mount · Sync- Mount
- Wall / Panel Mount
- Antrieb
- Synchronous (50/60Hz)
- Dial Step
- 24h · 15-min Segments
- Am besten geeignet für
- Stable-Grid Commercial
Mechanische Zeitschaltuhr TB118N
Heavy Duty · Quartz- Mount
- Wall / Panel Mount
- Antrieb
- Quartz · 300h Reserve
- Dial Step
- 24h · 15-min Captive
- Am besten geeignet für
- Irrigation & Pump Houses
Mechanische Zeitschaltuhr TB330
Heavy Duty · Wall- Mount
- Wall / Panel Mount
- Antrieb
- Quartz Battery Reserve
- Dial Step
- 24h · Heavy Microswitch
- Am besten geeignet für
- Industrial Heaters & Fans
TM1S Mechanische Zeitschaltuhr
Compact · 24h Dial- Mount
- Panel / Socket Style
- Antrieb
- Synchronous / Quartz
- Dial Step
- 24h · Easy Pin Dial
- Am besten geeignet für
- Appliances & Displays
Outdoor Light Mechanical Timer
Weatherproof · Outdoor- Mount
- Wetterfestes Gehäuse
- Antrieb
- 24-Hour Analog Dial
- Dial Step
- 24h · Splash-Resistant
- Am besten geeignet für
- Garden & Pool Lighting
Plug-In Mechanical Timer
Plug-and-Play · Retail- Mount
- Wall Socket Plug-In
- Antrieb
- 24-Hour Synchronous
- Dial Step
- 24h · 15/30-min Pins
- Am besten geeignet für
- Retail & Home Lamps
| Modell | Mount & Width | Drive & Battery Reserve | Dial Cycle & Min Step | Produktseite |
|---|---|---|---|---|
| SUL181d | 35 mm DIN Rail (3M · 52.5 mm) | Quartz · 150–200h Reserve | 24-Hour · 15-min captive segments (96 pins) | View SUL181d → |
| SUL181h | 35 mm DIN Rail (3M · 52.5 mm) | Quartz · 150–200h Reserve | 7-Day Weekly · 2-hour segments | View SUL181h → |
| SUL180a | 35 mm DIN Rail (1M · 18 mm Slim) | Synchronous (50/60Hz Grid) | 24-Hour · 15-min segments (Compact DBs) | View SUL180a → |
| SUL160a / SUL189s | 35 mm DIN Rail (1M–3M) | Quartz / Synchronous Options | 24-Hour · Manual ON/AUTO/OFF override | SUL160a → · SUL189s → |
| TB388 | Wall / Panel Surface Mount | Quartz · 100–300h Reserve | 24-Hour · 15-min captive pins · 15A–20A | View TB388 → |
| TB35 / TB38N | Wall / Panel Surface Mount | Quartz (TB35) / Sync (TB38N) | 24-Hour · 15-min segments · Clear Dust Cover | TB35 → · TB38N → |
| TB118N / TB330 | Wall / Panel Surface Mount | Quartz Battery Reserve | 24-Hour · Heavy-Duty Boiler, Pump & HVAC | TB118N → · TB330 → |
| TM1S / Plug-In / Outdoor | Socket Plug-In / Weatherproof | Synchronous / Quartz | 24-Hour · Garden Lights, Pool Pumps & Retail | TM1S → · Plug-In → · Outdoor → |
Choose Between Quartz Battery Reserve & Synchronous Drive
Select your grid reliability, mounting style, and dial cycle to match the exact SUL or TB mechanical timer model.
How a 96-Pin Mechanical Dial & ON/AUTO/OFF Override Works
Zero menus, zero programming mistakes for field staff. Step-by-step guide: How to Set a Timer Switch With Pins → & Troubleshooting Guide →.
Zero Training for Field Staff
Anyone opening a pump house or boiler room can verify or tweak a 24h pin dial in 5 seconds—whereas multi-zone cabinets needing weekly schedules use 7-day programmable and astronomical digital timer switches, and machine-control delays use electronic on-delay and off-delay timer relays.
Quartz 100–300h Outage Reserve
Internal NiMH rechargeable batteries in SUL181d und TB388 keep the gear train ticking accurately through grid blackouts—unlike synchronous timers.
Captive Pins Never Fall Out
SUL and TB series use retained captive segments molded into the dial ring so pins never get lost inside live electrical enclosures.
VIOX Mechanical Timers vs. Theben, Panasonic, Grasslin & Hager
Direct 35 mm DIN-rail widths and Panasonic wall-mount footprints for wholesalers, HVAC contractors, and OEM panel builders.
| Mechanical Timer Tier | Theben / Grasslin | Panasonic / Hager | VIOX Direct Equivalent | Kommerzieller & OEM-Mehrwert |
|---|---|---|---|---|
| 3M Quartz DIN-Rail | Theben SUL 181 d / h · Grasslin tactic 111 | Hager EH111 / EH171 | SUL181d (24h) · SUL181h (7d) | 45%–65% lower BOM cost; 150–200h quartz reserve |
| 1M Ultra-Slim DIN-Rail | Theben SYN 161 d · SUL 180 a | Hager EH010 / EH011 | SUL180a · SUL160a (18 mm 1M) | Drop-in 1-module footprint for compact consumer units |
| Wall-Mount Heavy Duty | Grasslin Wall Time Switch | Panasonic TB388 / TB35 / TB118N | TB388 · TB35 · TB38N · TB118N · TB330 | Direct mounting-hole & terminal match at factory pricing |
Eine ehrliche Einschätzung
If a project tender legally mandates sole-source German-made Theben or Japanese Panasonic with zero equivalents permitted, stay with that line item. For regional switchgear wholesalers, HVAC/pump contractors, and OEM panel builders needing exact SUL181d & TB388 compatibility, 45%–65% BOM savings, and OEM private-label branding, VIOX supplies directly from the factory.
Quotation Variables, 100% Quartz & Reserve QC & OEM Supply
Transparent factory pricing drivers, 24-hour gear-train accuracy tests, NiMH reserve checks, and OEM dial branding.
| Angebotsvariable | Standard Baseline | Engineered / Heavy-Duty Option | Factory Quote Impact |
|---|---|---|---|
| 1. Drive & Reserve | Synchronous 50Hz/60Hz (no battery: SUL180a / TB38N) | Quartz drive + NiMH battery reserve (SUL181d / TB388 / TB118N) | Quartz stepping motor + NiMH cell adds modest delta |
| 2. Housing & Width | 18 mm 1M DIN rail (SUL180a) | 52.5 mm 3M DIN (SUL181d) or wall-mount with hinged dust cover (TB388) | Larger dial, clear cover & terminal block scale cost |
| 3. Supply Frequency / Volts | 220–240V AC 50/60Hz (Quartz is dual-freq) | 110–120V AC 60Hz (mandatory spec on synchronous models) | Quartz models simplify 50/60Hz export stock |
| 4. OEM Dial & Batch | VIOX standard dial print & export box | OEM dial logo, custom color box, EAN barcode & multilingual insert | Samples 3–5 business days · Batch production 12–20 days |
1. 24h Gear-Train Accuracy QC
Every quartz and synchronous movement is run-tested to verify smooth gear meshing and accurate 24h/7d rotation.
2. NiMH Reserve Battery Check
Charge-retention testing verifies 100–300h outage backup on SUL181d / SUL181h / TB388 / TB118N.
3. Captive Pin & Microswitch QC
Pin snap-force checks and 16A–20A microswitch switching audits ensure crisp actuation across thousands of cycles.
4. One-PO Time-Control Supply
Consolidate SUL & TB mechanical timers with Digitale Zeitschaltuhren, Photocellsund Schütze.
Generate Your Mechanical Timer Switch RFQ Brief in 30 Seconds
Select target series, drive mechanism, supply voltage, and OEM packaging—copy or send directly to VIOX engineering.
Pin-Setting Guides, Troubleshooting & Companion Hubs
Engineering references authored by VIOX industrial time-control specialists.
How to Set a Timer Switch With Pins (Time, Pins & AUTO Mode)
Step-by-step guide to setting 15-minute captive pins and the 3-way ON/AUTO/OFF override switch.
Explore Guide →Mechanical Timer Switch Not Working? 10 Common Causes & Fixes
Diagnose stopped dials, 50/60Hz frequency mismatches, override errors, and welded microswitches.
Explore Guide →Mechanical Timer Switch vs. Digital Timer Switch: Engineer Guide
When to specify analog 96-pin dials versus LCD programmable timers for lights, pumps, and panels.
Explore Guide →Common Timer Switch Wiring Methods (Direct vs. Contactor Pilot)
Wiring schematics for SUL181d DIN-rail timers, TB388 wall units, and heavy-load contactors.
Explore Guide →Digital Timer Switches (THC 1C/2C & KG316T-II · 25 Models)
Upgrade to 1-minute weekly programming, 2 independent channels, and 3-year lithium backup.
Explore Guide →Modular Contactors (16A–63A) for Heavy Pumps & LED Banks
Protect mechanical timer microswitches from high motor starting current and LED driver surges.
Explore Guide →Mechanical Timer Switch Setting, Reserve & OEM Questions
Quartz vs Sync What is the difference between a Synchronous and a Quartz mechanical timer switch?
Synchronous mechanical timers (such as SUL180a or TB38N) lock onto mains frequency (50Hz or 60Hz) and stop advancing during a power outage—requiring manual clock resetting when power returns.
Quartz mechanical timers (such as SUL181d, SUL181h, TB388, and TB118N) include a built-in rechargeable NiMH battery providing 100–300 hours of power-reserve timekeeping across both 50Hz and 60Hz grids.
Pin Setting How do I set the pins on a 24-hour SUL181d or TB388 mechanical timer switch?
First rotate the dial clockwise until the current time aligns with the triangular index arrow. Never force the dial counter-clockwise.
Push outward (or downward on TB-series pins) each 15-minute segment for every period you want the load ON, then set the 3-way manual override switch to the center AUTO (clock) position.
Model Selection When should I choose a 1-module SUL180a versus a 3-module SUL181d or wall-mount TB388?
Choose SUL180a (18 mm · 1 module) when DIN-rail space is tight and grid outages are rare. Choose SUL181d (52.5 mm · 3 modules) for DIN-rail panels needing 150–200h quartz battery reserve and easy gloved finger setting.
Choose TB388, TB35, or TB118N for standalone wall-mount water heaters, pumps, and signage boxes.
Fehlerbehebung Why do mechanical timers stop keeping time or fail to switch?
Most field issues come from leaving the manual override switch on permanent ON/OFF instead of AUTO, installing a 50Hz synchronous unit on a 60Hz grid, or switching high-inrush motors above the microswitch rating without a contactor.
Cross-Reference Are VIOX SUL181d and TB388 timers drop-in replacements for Theben SUL 181 d and Panasonic TB388?
Yes. VIOX SUL181d/181h/180a match standard 35 mm DIN-rail widths and Theben/Grasslin terminal numbering, while TB388/TB35/TB118N match standard Panasonic wall-mount footprints—delivering 45%–65% lower wholesale cost.
Werks-QC What factory QC tests and OEM options does VIOX provide for mechanical timer switches?
Every batch undergoes 24-hour quartz/synchronous accuracy checks, NiMH reserve-battery charge/discharge verification, captive-pin snap-force testing, and 16A–20A microswitch endurance testing, with OEM dial branding and private-label boxes.
Need SUL181d, SUL180a or TB388 Mechanical Timer Samples & Pricing?
Share your target drive type (quartz reserve vs. synchronous), supply voltage, and OEM dial/box requirements. VIOX factory sales will reply with sample dispatch details within 24 hours.