Termostat na DIN lištu NTS01/NTS10

Skříňové termostaty řady VIOX NTS01/NTS10 jsou určeny pro regulaci teploty uvnitř elektrických skříní a rozvaděčů. S verzemi SPST-NC a SPST-NO, montáží na 35mm DIN lištu a rozsahem nastavení 0 až 60 °C jsou vhodné pro aplikace regulace topení, ventilátorů, chlazení a alarmů.

Contact Options
SPST-NC / SPST-NO
Rozsah nastavení
0 až +60 °C
Montáž
35mm DIN lišta
Ochrana
IP20

Přehled produktů

The VIOX NTS01/NTS10 cabinet thermostat series regulates temperature inside electrical enclosures, control cabinets, and industrial panels. Its compact 18mm-wide housing mounts on a standard 35mm DIN rail, helping panel builders control heaters, fans, cooling devices, warning lights, and alarm circuits from one adjustable thermostat platform.

The series provides two contact functions for different control tasks. NTS01-60 uses a normally closed contact for heating and anti-condensation control. NTS10-60 uses a normally open contact for cooling, ventilation, and signaling. Both models cover a 0 to +60°C setting range.

Možnosti modelu

ModelTyp kontaktuKontaktní formulářHlavní aplikace
NTS01-60SPST-NCNormálně zavřenýRegulace topení a odvlhčování
NTS10-60SPST-NONormálně otevřenýVentilátor, chladicí zařízení, výstražné světlo a regulace alarmu

Klíčové vlastnosti

  • Dvě verze termostatu pro regulaci topení a chlazení
  • Rozsah nastavení teploty od 0 do +60 °C
  • Compact 18mm-wide design for electrical cabinet installation
  • 35mm DIN rail mounting according to EN 60715
  • Bimetal thermostat element for temperature sensing and switching
  • Vhodné pro ohřívače, filtrační ventilátory, chladicí zařízení a alarmovou signalizaci
  • Flexible mounting position inside enclosures and control panels

Technické specifikace

ParametrSpecifikace
Temperature setting range0 až +60 °C
Switching difference7K (+/−4K)
Temperature sensorBimetalový termostatický prvek
Kontaktní odpor≤50mΩ
Životnost>100 000 cyklů
Hodnocení kontaktu10(2)A at 250VAC; 15(2)A at 120VAC; 30W at DC24V to 72V
Connection terminalDvoupólová šroubová svorka
Rigid wire capacity2,5 mm²
Flexible wire capacity1,5 mm² s dutinkou
Způsob montáže35mm DIN rail, EN 60715
Materiál krytuŠedý samozhášivý ABS
Rozměry86 × 48 × 18mm
Montážní polohaLibovolná poloha
Okolní teplota−45°C to +80°C
Okolní vlhkost≤90% RH, nekondenzující
Stupeň ochranyIP20
HmotnostPřibližně 40 g

How the Two Models Work

Choose the contact function according to the equipment that must switch when enclosure temperature moves below or above the selected setpoint.

NTS01-60: Heating Control

The normally closed contact is used with heaters and anti-condensation equipment. When enclosure temperature falls below the set value, the circuit supports heating or dehumidification control.

NTS10-60: Cooling and Signaling

The normally open contact is used with fans, cooling equipment, warning lights, and alarms. When enclosure temperature rises above the set value, it can activate ventilation, cooling, or signaling equipment.

Aplikace

Typical enclosure climate-control and signaling applications for the NTS01/NTS10 series include:

  • Electrical enclosures and distribution panels
  • Průmyslové řídicí skříně
  • Panel heaters and anti-condensation systems
  • Filtrační ventilátory a chladicí ventilátory
  • Cooling devices for cabinet climate control
  • Warning lights and alarm circuits

Proč si vybrat termostaty VIOX NTS01/NTS10

The NTS01/NTS10 series gives panel builders, OEMs, and distributors a clear choice between heating and cooling control in the same compact DIN rail format. The two contact versions simplify model selection while supporting common enclosure climate-control and signaling tasks.

  • Jasný výběr modelu pro regulaci topení nebo chlazení
  • Compact housing for space-conscious panel layouts
  • Straightforward 35mm DIN rail installation
  • One thermostat family for climate-control and signaling applications
  • Vhodné pro OEM, distributory a projektové zakázky

ČASTO KLADENÉ DOTAZY

Jaký je rozdíl mezi NTS01 a NTS10?

NTS01-60 is an SPST-NC normally closed thermostat for heater and dehumidification control. NTS10-60 is an SPST-NO normally open thermostat for fan, cooling, warning-light, and alarm control.

Jaký je rozsah nastavení teploty?

Both models cover an adjustable setting range from 0 to +60°C.

Jak se termostat montuje?

The thermostat mounts on a standard 35mm DIN rail according to EN 60715.

Jaké zátěže může tento termostat spínat?

The available product data lists 10(2)A at 250VAC, 15(2)A at 120VAC, and 30W at DC24V to 72V.

Kde se tento termostat běžně používá?

Typical applications include electrical enclosures, control cabinets, panel heaters, filter fans, cooling devices, warning lights, and alarm systems.

Need an NTS01/NTS10 Thermostat Quote?
Let’s Confirm the Right Contact Type.

Send us the required heating, cooling, or signaling function, model, quantity, and project requirements. Our team will review the application and respond within one business day.

Požádat o cenovou Nabídku