The VIOX NTS01/NTS10 cabinet thermostat series regulates temperature inside electrical enclosures, control cabinets, and industrial panels. Its compact 18mm-wide housing mounts on a standard 35mm DIN rail, helping panel builders control heaters, fans, cooling devices, warning lights, and alarm circuits from one adjustable thermostat platform.
The series provides two contact functions for different control tasks. NTS01-60 uses a normally closed contact for heating and anti-condensation control. NTS10-60 uses a normally open contact for cooling, ventilation, and signaling. Both models cover a 0 to +60°C setting range.
Možnosti modelu
| Model | Typ kontaktu | Kontaktní formulář | Hlavní aplikace |
|---|---|---|---|
| NTS01-60 | SPST-NC | Normálně zavřený | Regulace topení a odvlhčování |
| NTS10-60 | SPST-NO | Normálně otevřený | Ventilátor, chladicí zařízení, výstražné světlo a regulace alarmu |
Klíčové vlastnosti
- Dvě verze termostatu pro regulaci topení a chlazení
- Rozsah nastavení teploty od 0 do +60 °C
- Compact 18mm-wide design for electrical cabinet installation
- 35mm DIN rail mounting according to EN 60715
- Bimetal thermostat element for temperature sensing and switching
- Vhodné pro ohřívače, filtrační ventilátory, chladicí zařízení a alarmovou signalizaci
- Flexible mounting position inside enclosures and control panels
Technické specifikace
| Parametr | Specifikace |
|---|---|
| Temperature setting range | 0 až +60 °C |
| Switching difference | 7K (+/−4K) |
| Temperature sensor | Bimetalový termostatický prvek |
| Kontaktní odpor | ≤50mΩ |
| Životnost | >100 000 cyklů |
| Hodnocení kontaktu | 10(2)A at 250VAC; 15(2)A at 120VAC; 30W at DC24V to 72V |
| Connection terminal | Dvoupólová šroubová svorka |
| Rigid wire capacity | 2,5 mm² |
| Flexible wire capacity | 1,5 mm² s dutinkou |
| Způsob montáže | 35mm DIN rail, EN 60715 |
| Materiál krytu | Šedý samozhášivý ABS |
| Rozměry | 86 × 48 × 18mm |
| Montážní poloha | Libovolná poloha |
| Okolní teplota | −45°C to +80°C |
| Okolní vlhkost | ≤90% RH, nekondenzující |
| Stupeň ochrany | IP20 |
| Hmotnost | Přibližně 40 g |
How the Two Models Work
Choose the contact function according to the equipment that must switch when enclosure temperature moves below or above the selected setpoint.
NTS01-60: Heating Control
The normally closed contact is used with heaters and anti-condensation equipment. When enclosure temperature falls below the set value, the circuit supports heating or dehumidification control.
NTS10-60: Cooling and Signaling
The normally open contact is used with fans, cooling equipment, warning lights, and alarms. When enclosure temperature rises above the set value, it can activate ventilation, cooling, or signaling equipment.
Aplikace
Typical enclosure climate-control and signaling applications for the NTS01/NTS10 series include:
- Electrical enclosures and distribution panels
- Průmyslové řídicí skříně
- Panel heaters and anti-condensation systems
- Filtrační ventilátory a chladicí ventilátory
- Cooling devices for cabinet climate control
- Warning lights and alarm circuits
Proč si vybrat termostaty VIOX NTS01/NTS10
The NTS01/NTS10 series gives panel builders, OEMs, and distributors a clear choice between heating and cooling control in the same compact DIN rail format. The two contact versions simplify model selection while supporting common enclosure climate-control and signaling tasks.
- Jasný výběr modelu pro regulaci topení nebo chlazení
- Compact housing for space-conscious panel layouts
- Straightforward 35mm DIN rail installation
- One thermostat family for climate-control and signaling applications
- Vhodné pro OEM, distributory a projektové zakázky
ČASTO KLADENÉ DOTAZY
Jaký je rozdíl mezi NTS01 a NTS10?
NTS01-60 is an SPST-NC normally closed thermostat for heater and dehumidification control. NTS10-60 is an SPST-NO normally open thermostat for fan, cooling, warning-light, and alarm control.
Jaký je rozsah nastavení teploty?
Both models cover an adjustable setting range from 0 to +60°C.
Jak se termostat montuje?
The thermostat mounts on a standard 35mm DIN rail according to EN 60715.
Jaké zátěže může tento termostat spínat?
The available product data lists 10(2)A at 250VAC, 15(2)A at 120VAC, and 30W at DC24V to 72V.
Kde se tento termostat běžně používá?
Typical applications include electrical enclosures, control cabinets, panel heaters, filter fans, cooling devices, warning lights, and alarm systems.