VIOX Điện
Language

Máy cắt điện thu nhỏ VOB3-63H

The VIOX VOB3-63H miniature circuit breaker provides overload and short-circuit protection for AC 50/60 Hz circuits. It covers rated currents from 1 A to 63 A, B, C and D tripping curves, and 1P to 4P configurations. Its 10 kA breaking capacity supports DIN-rail installation in residential, commercial and light-industrial distribution systems.

Bình Hiện Tại
1-63 A
Cấu hình cực
1P, 2P, 3P, 4P
Tripping Curves
B, C, D
Khả Năng Phá Vỡ
10 kA

Tổng quan

The VOB3-63H is a miniature circuit breaker for overload and short-circuit protection in AC 50/60 Hz electrical circuits. It provides a rated short-circuit breaking capacity of 10 kA and covers rated currents from 1 A to 63 A. Available configurations include 1P, 2P, 3P and 4P versions with B, C or D tripping curves. The breaker is designed for DIN-rail installation in distribution boards, consumer units and control panels used in residential, commercial and light-industrial distribution systems. Rated-voltage options listed in the catalog extend up to 240/400 V or 400 V, depending on pole configuration.

Đặc trưng

  • Overload and short-circuit protection for AC 50/60 Hz circuits.
  • Rated short-circuit breaking capacity of 10 kA.
  • Rated-current range from 1 A to 63 A.
  • B, C and D tripping-curve options.
  • Available in 1P, 2P, 3P and 4P configurations.
  • Compact 18 mm unipolar width with contact-position indication and top or bottom power entry.

Mô hình

Catalog designation Cấu hình cực
VOB3-63H 1P 1P
VOB3-63H 2P 2P
VOB3-63H 3P 3P
VOB3-63H 4P 4 P

Thông số kỹ thuật

Electrical Data

Tham số Đặc điểm kỹ thuật
Rated frame current 63 A
Dòng điện định mức 1, 2, 3, 4, 6, 10, 16, 20, 25, 32, 40, 50, 63 A
Bình áp 240/400 V (1P, 2P); 400 V (2P, 3P, 4P)
Tần số định mức 50/60 Hz
Điện áp cách điện định mức (Ui) 500 V
Điện áp chịu xung định mức (Uimp) 4 kV
Dielectric strength test voltage (1 min) 2 kV
Rated short-circuit breaking capacity 10 kA

Protection Data

Tham số Đặc điểm kỹ thuật
Tripping curves B (3-5 In), C (5-10 In), D (10-20 In)
Mức độ bảo vệ IP20

Mechanical Data

Tham số Đặc điểm kỹ thuật
Số cực 1P, 2P, 3P, 4P
Unipolar width 18 mm
Cuộc sống cơ học 20.000 lần hoạt động
Cuộc sống điện 4,000 operations

Installation Data

Tham số Đặc điểm kỹ thuật
Cài đặt DIN
Khả năng đấu nối dây dẫn 25 mm²
Incoming method Top or bottom power entry

Environmental and Standards Data

Tham số Đặc điểm kỹ thuật
Nhiệt độ tham chiếu 30 °C
Compliant standards GB/T 10963.1, IEC 60898-1

Hướng dẫn lựa chọn

Code position Ý nghĩa Catalog value or options
VO Enterprise identification VO
B Aptomat dạng tép (MCB) B
3 Design serial number 3
60 Shell frame current 60
B / C / D Tripping curve B, C or D
Rated-current code Dòng điện định mức 1 A, 2 A, 3 A, 4 A, 6 A, 10 A, 16 A, 20 A, 25 A, 32 A, 40 A, 50 A or 63 A
H Short-circuit breaking-capacity level code H
1P / 2P / 3P / 4P Số cực 1P, 2P, 3P or 4P

Bình Hiện Tại

Select one of the catalog ratings from 1 A to 63 A according to the circuit rating and protection requirements.

Đường cong vấp ngã

Choose B, C or D according to the required instantaneous tripping range: B (3-5 In), C (5-10 In) or D (10-20 In).

Cấu hình cực

Select a 1P, 2P, 3P or 4P configuration to match the circuit arrangement.

Điện áp định mức

Confirm the catalog voltage for the selected pole configuration: 240/400 V is listed for 1P and 2P, while 400 V is listed for 2P, 3P and 4P.

Đường cong chuyến đi

Đặc trưng Catalog value
Agreed non-tripping time at 1.13 In, cold state, for In ≤ 63 A 1 h
Agreed tripping time at 1.45 In, hot state, for In ≤ 63 A 1 h
B instantaneous characteristic 3-5 In
C instantaneous characteristic 5-10 In
D instantaneous characteristic 10-20 In

Kích thước

VOB3-63H MCB dimensional drawing
VOB3-63H MCB dimensional drawing.

Ứng dụng

  • Residential electrical distribution systems.
  • Commercial distribution boards.
  • Light-industrial control panels.
  • Consumer units requiring overload and short-circuit protection.

Cài đặt

  • Install the selected configuration on a DIN rail in a suitable distribution board, consumer unit or control panel.
  • Confirm that the circuit voltage, rated current, pole configuration and tripping curve match the selected breaker.
  • Use conductors within the listed 25 mm² wiring capacity.
  • Power entry may be made from the top or bottom.

Câu hỏi thường gặp

What protection does the VOB3-63H provide?

It provides overload and short-circuit protection for AC 50/60 Hz electrical circuits.

What rated currents and tripping curves are available?

The catalog lists rated currents from 1 A to 63 A with B, C and D tripping curves.

Which pole configurations are offered?

The VOB3-63H is available in 1P, 2P, 3P and 4P configurations.

What is the rated short-circuit breaking capacity?

The rated short-circuit breaking capacity is 10 kA.

How is the VOB3-63H installed and connected?

It is designed for DIN-rail installation, has a listed wiring capacity of 25 mm² and permits top or bottom power entry.

Which standards are listed for the VOB3-63H?

The technical specifications list GB/T 10963.1 and IEC 60898-1.

Need a Product Quote?
Hãy cùng chúng tôi thực hiện dự án này.

Send us the product model, technical ratings, quantity, and OEM requirements. Our team will review your application and respond within one business day.

Yêu cầu báo giá