VIOX ELECTRIC
Ngôn ngữ

VIOX VOAP2-100A 100A Three-Source Power Phase Selector with Over/Under Voltage, Current & Alarm Relay

The VIOX VOAP2-100A is a heavy-duty 100 A three-source (3 × L+N) automatic power selector that routes three independent single-phase or 3-phase 220 V sources into a single protected output with simultaneous L+N disconnection, integrated audible buzzer, NC/COM/NO dry-contact alarm output, and 99-event fault memory.

Mẫu VIOX
VOAP2-100A
Điện áp
3×220 V AC (L+N × 3 Inputs)
Hiện hành
100 A · NC/COM/NO Alarm
Định dạng
Ray DIN 35 mm

Tổng quan

The VIOX VOAP2-100A is a heavy-duty 100 A three-source (3 × L+N) automatic power selector that routes three independent single-phase or 3-phase 220 V sources into a single protected output with simultaneous L+N disconnection, integrated audible buzzer, NC/COM/NO dry-contact alarm output, and 99-event fault memory.

Đặc trưng

  • Accepts 3 independent L+N 220 V AC power inputs and outputs 1 continuous protected L+N supply up to 100 A.
  • Full adjustable Over-Voltage (220–300 V), Under-Voltage (150–210 V), Over-Current (1–100 A), and phase-anomaly protection.
  • Simultaneous L + N disconnection per source with individual front manual override rocker switches.
  • Built-in audible alarm buzzer + dry-contact NC/COM/NO relay terminals for remote BMS/SCADA alerting.

Thông số kỹ thuật

VOAP2-100A Technical Specifications

Tham sốĐặc điểm kỹ thuật
Input / Output3 × (L+N) 220 V AC Inputs → 1 × (L+N) 100 A Output
ProtectionsAdjustable Over-Voltage (220–300 V), Under-Voltage (150–210 V), Over-Current (1–100 A)
Alarm & MemoryNC / COM / NO dry alarm contacts + built-in buzzer + fault history
Recovery & Mounting1–500 s adjustable auto-recovery · 35 mm DIN rail · CE

Wiring & Setup Guide

  • Connect three independent 220 V L+N sources to Power I, Power II, and Power III IN terminals; wire the protected load to OUT (N, L) and optional remote alarm to NC/COM/NO.
  • Explore the complete VIOX Voltage Protectors catalog for matched DIN-rail switchgear.

Câu hỏi thường gặp

How is VOAP2-100A different from VOPD3-100VAYA?

VOAP2-100A accepts three fully independent L+N power sources (cutting both L and N), adds front manual source rocker switches, and includes a built-in buzzer plus NC/COM/NO alarm relay contacts.

Cần báo giá sản phẩm?
Hãy cùng chúng tôi thực hiện dự án này.

Gửi cho chúng tôi mã sản phẩm, các định mức kỹ thuật, số lượng và yêu cầu OEM. Đội ngũ của chúng tôi sẽ xem xét ứng dụng của bạn và phản hồi trong vòng một ngày làm việc.

Yêu cầu báo giá