VIOX ELECTRIC
Nyelv

VIOX VOAP2-100A 100A Three-Source Power Phase Selector with Over/Under Voltage, Current & Alarm Relay

The VIOX VOAP2-100A is a heavy-duty 100 A three-source (3 × L+N) automatic power selector that routes three independent single-phase or 3-phase 220 V sources into a single protected output with simultaneous L+N disconnection, integrated audible buzzer, NC/COM/NO dry-contact alarm output, and 99-event fault memory.

VIOX modell
VOAP2-100A
Feszültség
3×220 V AC (L+N × 3 Inputs)
Jelenlegi
100 A · NC/COM/NO Alarm
Formátum
35 mm-es DIN-sín

Áttekintés

The VIOX VOAP2-100A is a heavy-duty 100 A three-source (3 × L+N) automatic power selector that routes three independent single-phase or 3-phase 220 V sources into a single protected output with simultaneous L+N disconnection, integrated audible buzzer, NC/COM/NO dry-contact alarm output, and 99-event fault memory.

Jellemzők

  • Accepts 3 independent L+N 220 V AC power inputs and outputs 1 continuous protected L+N supply up to 100 A.
  • Full adjustable Over-Voltage (220–300 V), Under-Voltage (150–210 V), Over-Current (1–100 A), and phase-anomaly protection.
  • Simultaneous L + N disconnection per source with individual front manual override rocker switches.
  • Built-in audible alarm buzzer + dry-contact NC/COM/NO relay terminals for remote BMS/SCADA alerting.

Műszaki adatok

VOAP2-100A Technical Specifications

ParaméterSpecifikáció
Input / Output3 × (L+N) 220 V AC Inputs → 1 × (L+N) 100 A Output
ProtectionsAdjustable Over-Voltage (220–300 V), Under-Voltage (150–210 V), Over-Current (1–100 A)
Alarm & MemoryNC / COM / NO dry alarm contacts + built-in buzzer + fault history
Recovery & Mounting1–500 s adjustable auto-recovery · 35 mm DIN rail · CE

Wiring & Setup Guide

  • Connect three independent 220 V L+N sources to Power I, Power II, and Power III IN terminals; wire the protected load to OUT (N, L) and optional remote alarm to NC/COM/NO.
  • Explore the complete VIOX Voltage Protectors catalog for matched DIN-rail switchgear.

GYIK

How is VOAP2-100A different from VOPD3-100VAYA?

VOAP2-100A accepts three fully independent L+N power sources (cutting both L and N), adds front manual source rocker switches, and includes a built-in buzzer plus NC/COM/NO alarm relay contacts.

Termékajánlatot kérne?
Építsük fel együtt.

Küldje el nekünk a termékmodelljét, a műszaki jellemzőket, a mennyiséget és az OEM-követelményeket. Csapatunk áttekinti az alkalmazást, és egy munkanapon belül válaszol.

Kérjen Árajánlatot