Genel Bakış
VOSA4-GK 1000V VIOX Electric is a professional manufacturer of the 1000V DC High Speed Semiconductor Protection Fuse, an ultra-rapid fuse engineered for DC 1000V systems with a current range of 1000A-2500A and a 50kA interrupting rating (time constant 1-3ms). As an aR class fast-acting fuse, it delivers superior current-limiting performance with precisely characterized I²t values, fully compliant with IEC60269-4 and GB/T13539.4, making it a trusted solution for high-power DC protection in energy storage, traction, and industrial applications.
VIOX Electric is a professional manufacturer of the 1000V DC High Speed Semiconductor Protection Fuse, a high-speed square body fuse series specifically engineered for protecting power semiconductor devices including IGBTs, thyristors, diodes, and SCRs in demanding DC 1000V power conversion systems. This ultra-rapid fuse is designed to deliver reliable short-circuit and overcurrent protection for energy storage systems, traction power supplies, rectifiers, and industrial drives, where component safety and system uptime are critical.
Özellikler
- Rated voltage 1000VDC and current capacity 1000A for ess & semiconductor high-speed fuse applications.
- High interrupting performance (50kA) with rapid current-limiting fault clearing.
- Engineered and tested in accordance with GB/T13539.4 / IEC60269-4 standards.
- Precision-engineered low-power-loss silver-plated contacts and high-temperature ceramic or flame-retardant housing.
- Direct OEM replacement geometry for standardized industrial, solar PV, ESS, and EV protection panels.
Teknik Özellikler
VOSA4-GK Technical Specifications
| Seri numarası | Rated Current A | Pre-arcing I²t A²s | Melting I²t A²s | Power dissipation W |
| 1 | 1000 | 143000 | 955000 | 195 |
| 2 | 1250 | 210000 | 1420000 | 205 |
| 3 | 1400 | 311000 | 2110000 | 220 |
| 4 | 1600 | 590000 | 3920000 | 245 |
| 5 | 2000 | 1210000 | 7810000 | 275 |
| 6 | 2500 | 1990000 | 13300000 | 305 |
VOSA4-GK Ratings & Dimensions Table 2
| Rated Current (A) | Conventional Time (h) | Conventional Current | |
| “gR” | |||
| Inf | lf | ||
| ln≤63 | 1 | 1.13ln | 1.6ln |
| 63<In≤160 | 2 | ||
| 160<ln≤400 | 3 | ||
| 400<ln | 4 | ||
| Note:ln is the rated current of the fuse; lnf is the conventional non-fusing current; if is the conventional fusing current. | |||
Selection & Installation Notes
- Verify system maximum voltage (1000VDC) and prospective short-circuit fault current before selecting the fuse link or holder rating.
- Apply ambient-temperature derating when operating inside sealed outdoor combiner boxes or high-density inverter cabinets above 40°C.
- Always de-energize circuits before replacing cylindrical, blade, or bolted fuse links, and use insulated fuse pullers for NH/NT types.
- Explore the complete VIOX Fuse & Fuse Holder catalog for matched holders, bases, and disconnectors.
SSS
What voltage and current ratings does the VIOX VOSA4-GK 1000V DC High Speed Semiconductor Protection Fuse support?
This VIOX VOSA4-GK series is rated for 1000VDC with a current rating of 1000A and 50kA breaking performance. Refer to the technical specification table above for individual part numbers and ampere steps.
Which international standards apply to VIOX VOSA4-GK 1000V DC High Speed Semiconductor Protection Fuse?
The VOSA4-GK series is designed and verified to GB/T13539.4 / IEC60269-4 requirements for safe overcurrent and short-circuit protection.
Where is the VIOX VOSA4-GK 1000V DC High Speed Semiconductor Protection Fuse typically installed?
It is engineered for ess & semiconductor high-speed fuse circuits, protecting cables, busbars, semiconductors, battery modules, or string feeders against thermal overload and high-energy short-circuit faults.
Can VIOX supply matched fuse holders, bases, or OEM private-label packaging?
Yes. VIOX Electric supplies matched DIN-rail fuse holders, NH/NT fuse bases, disconnectors, and OEM/ODM bulk packaging with technical datasheets upon RFQ.



