Pangkalahatang-ideya
The VAF3-40M is a magnetic arc fault detection device combining arc-fault detection with Type A residual-current, overload and short-circuit protection. Designed for AC 50 Hz final circuits, it has a rated voltage of 240 V AC and is available in rated currents from 6 A to 40 A. The 1P+N device offers B or C overcurrent tripping characteristics and 10 mA or 30 mA residual-current sensitivities. It is intended for residential and commercial final circuits requiring combined protection against arc faults, electric shock, overload and short circuits.
Mga tampok
- Magnetic version with integrated arc-fault, Type A residual-current, overload and short-circuit protection.
- Sumusunod sa IEC/EN 61009-1 at IEC/EN 62606.
- Mga opsyon para sa rated-current mula 6 A hanggang 40 A.
- Mga katangian ng overcurrent tripping na B at C.
- 10 mA at 30 mA na residual-current sensitivities.
- Load-disconnect contact na may 6 kA rated short-circuit current.
Mga pagtutukoy
Datos Elektrikal
| Parameter | Pagtutukoy |
|---|---|
| Rated current (In) | 6, 10, 13, 16, 20, 25, 32, 40 A |
| Rated voltage (Ue) | 240 V AC |
| Daloy ng paggana | 50 Hz |
| Minimum na operating voltage ng test-circuit | 196 V |
| Maximum na operating voltage ng test-circuit | 253 V |
| Rated na boltahe ng pagkakabukod (Ui) | 250 V |
| Na-rate na impulse withstand boltahe (Uimp) | 4 kV |
| Rated short-circuit current | 6 kA |
| Pinakamataas na kabuuang rated switching capacity | 6 kA |
| Lakas ng paglaban sa surge-current | 0.25 kA |
| Pagkawala ng kuryente bawat current path | 3 W |
| Short-circuit back-up fuse (SCPD) | 100 A |
| Uri ng back-up fuse | gG |
| Kategorya ng overvoltage | III |
Data ng Proteksiyon
| Parameter | Pagtutukoy |
|---|---|
| Konpigurasyon ng produkto | AFDD na may integrated Type A residual-current, proteksiyon sa sobrang karga at short circuit |
| Bilang ng mga poste | 1P+N |
| Uri ng natitirang agos | Uri A |
| Rated residual operating current (IΔn) | 10, 30 mA |
| Katangian ng pag-trip dahil sa overcurrent | B, C |
| Espesipikasyon ng load-circuit | Load-disconnect contact |
Data ng instalasyon
| Parameter | Pagtutukoy |
|---|---|
| Uri ng terminal | Screw-type terminals; koneksyon sa itaas o ibaba sa load circuit |
| Posisyon ng neutral conductor | Kaliwa o kanan |
| Pinakamahabang haba ng nakakonektang cable | 70 m sa pagitan ng distribution board at ng pinakamalayong socket outlet |
| Kapasidad ng pag-clamp ng terminal | 1-25 mm² |
| Terminal tightening torque | 2-2.4 N·m |
Data ng mga Pamantayan
| Parameter | Pagtutukoy |
|---|---|
| Mga naaangkop na pamantayan | IEC/EN 61009-1; IEC/EN 62606 |
Gabay sa Pagpili
| Posisyon ng code | Ibig sabihin | Sanggunian sa catalog |
|---|---|---|
| V | VIOX identification | V |
| AF | Pamilya ng produkto para sa proteksiyon laban sa arc-fault | AF |
| 3 | Design series | 3 |
| 40 | Maximum na frame current | 40 |
| M | Magnetic version | M |
| C16 | C tripping characteristic at rated current | 16 A |
| A30 | Ang Type A residual-current protection | 30 mA |
Na-rate na Kasalukuyan
Pumili ng nakalistang rating mula 6 A hanggang 40 A upang tumugma sa rating ng final-circuit.
Tripping Characteristic
Pumili ng B o C na overcurrent tripping characteristic ayon sa mga kinakailangan ng circuit.
Residual Sensitivity
Pumili ng Type A na residual operating-current sensitivity na 10 mA o 30 mA.
Mga application
- Mga final circuit sa residensyal.
- Mga final circuit sa komersyal.
- Circuits requiring combined arc-fault and electric-shock protection.
- Circuits requiring combined overload and short-circuit protection.
Pag-install
- Gumamit ng mga screw-type terminal na may koneksiyon sa itaas o ibaba sa load circuit.
- Kumpirmahin kung ang napiling configuration ay naglalagay sa neutral conductor sa kaliwa o kanan.
- Gumamit ng mga conductor na nasa loob ng nakalistang terminal clamping capacity na 1-25 mm².
- Ilapat ang nakalistang terminal tightening torque na 2-2.4 N·m.
- Panatilihin ang haba ng nakakonektang cable sa loob ng 70 m sa pagitan ng distribution board at ng pinakamalayong socket outlet.
- Gamitin ang nakalistang 100 A gG short-circuit back-up fuse.
Mga Download
FAQ
What distinguishes the VAF3-40M?
The catalog identifies the VAF3-40M as the magnetic version of the arc fault detection device.
Which protection functions are integrated?
Pinagsasama nito ang arc-fault detection sa Type A residual-current, sobrang karga, at short circuit protection.
Anong mga rated current at tripping characteristic ang available?
Nakalista sa catalog ang mga rating na 6, 10, 13, 16, 20, 25, 32, at 40 A na may B o C overcurrent tripping characteristics.
Anong mga residual current sensitivity ang inaalok?
The VAF3-40M provides Type A residual-current protection with 10 mA or 30 mA sensitivity.
What is the rated short-circuit current?
Ang rated short-circuit current ay 6 kA.
Which standards are listed for the VAF3-40M?
Ang mga naaangkop na pamantayan ay IEC/EN 61009-1 at IEC/EN 62606.