VAF3-40M Magnetic Arc Fault Detection Device

The VIOX VAF3-40M magnetic arc fault detection device combines arc-fault detection with Type A residual-current, overload and short-circuit protection. Designed for 240 V AC, 50 Hz final circuits, it is available in 6-40 A ratings, B or C tripping characteristics and 10 or 30 mA sensitivities for residential and commercial installations.

Na-rate na Kasalukuyan
6-40 A
Residual Current
10, 30 mA
Tripping Characteristic
B, C
Short-Circuit Current
6 kA

Pangkalahatang-ideya

The VAF3-40M is a magnetic arc fault detection device combining arc-fault detection with Type A residual-current, overload and short-circuit protection. Designed for AC 50 Hz final circuits, it has a rated voltage of 240 V AC and is available in rated currents from 6 A to 40 A. The 1P+N device offers B or C overcurrent tripping characteristics and 10 mA or 30 mA residual-current sensitivities. It is intended for residential and commercial final circuits requiring combined protection against arc faults, electric shock, overload and short circuits.

Mga tampok

  • Magnetic version with integrated arc-fault, Type A residual-current, overload and short-circuit protection.
  • Sumusunod sa IEC/EN 61009-1 at IEC/EN 62606.
  • Mga opsyon para sa rated-current mula 6 A hanggang 40 A.
  • Mga katangian ng overcurrent tripping na B at C.
  • 10 mA at 30 mA na residual-current sensitivities.
  • Load-disconnect contact na may 6 kA rated short-circuit current.

Mga pagtutukoy

Datos Elektrikal

Parameter Pagtutukoy
Rated current (In) 6, 10, 13, 16, 20, 25, 32, 40 A
Rated voltage (Ue) 240 V AC
Daloy ng paggana 50 Hz
Minimum na operating voltage ng test-circuit 196 V
Maximum na operating voltage ng test-circuit 253 V
Rated na boltahe ng pagkakabukod (Ui) 250 V
Na-rate na impulse withstand boltahe (Uimp) 4 kV
Rated short-circuit current 6 kA
Pinakamataas na kabuuang rated switching capacity 6 kA
Lakas ng paglaban sa surge-current 0.25 kA
Pagkawala ng kuryente bawat current path 3 W
Short-circuit back-up fuse (SCPD) 100 A
Uri ng back-up fuse gG
Kategorya ng overvoltage III

Data ng Proteksiyon

Parameter Pagtutukoy
Konpigurasyon ng produkto AFDD na may integrated Type A residual-current, proteksiyon sa sobrang karga at short circuit
Bilang ng mga poste 1P+N
Uri ng natitirang agos Uri A
Rated residual operating current (IΔn) 10, 30 mA
Katangian ng pag-trip dahil sa overcurrent B, C
Espesipikasyon ng load-circuit Load-disconnect contact

Data ng instalasyon

Parameter Pagtutukoy
Uri ng terminal Screw-type terminals; koneksyon sa itaas o ibaba sa load circuit
Posisyon ng neutral conductor Kaliwa o kanan
Pinakamahabang haba ng nakakonektang cable 70 m sa pagitan ng distribution board at ng pinakamalayong socket outlet
Kapasidad ng pag-clamp ng terminal 1-25 mm²
Terminal tightening torque 2-2.4 N·m

Data ng mga Pamantayan

Parameter Pagtutukoy
Mga naaangkop na pamantayan IEC/EN 61009-1; IEC/EN 62606

Gabay sa Pagpili

Posisyon ng code Ibig sabihin Sanggunian sa catalog
V VIOX identification V
AF Pamilya ng produkto para sa proteksiyon laban sa arc-fault AF
3 Design series 3
40 Maximum na frame current 40
M Magnetic version M
C16 C tripping characteristic at rated current 16 A
A30 Ang Type A residual-current protection 30 mA

Na-rate na Kasalukuyan

Pumili ng nakalistang rating mula 6 A hanggang 40 A upang tumugma sa rating ng final-circuit.

Tripping Characteristic

Pumili ng B o C na overcurrent tripping characteristic ayon sa mga kinakailangan ng circuit.

Residual Sensitivity

Pumili ng Type A na residual operating-current sensitivity na 10 mA o 30 mA.

Mga application

  • Mga final circuit sa residensyal.
  • Mga final circuit sa komersyal.
  • Circuits requiring combined arc-fault and electric-shock protection.
  • Circuits requiring combined overload and short-circuit protection.

Pag-install

  • Gumamit ng mga screw-type terminal na may koneksiyon sa itaas o ibaba sa load circuit.
  • Kumpirmahin kung ang napiling configuration ay naglalagay sa neutral conductor sa kaliwa o kanan.
  • Gumamit ng mga conductor na nasa loob ng nakalistang terminal clamping capacity na 1-25 mm².
  • Ilapat ang nakalistang terminal tightening torque na 2-2.4 N·m.
  • Panatilihin ang haba ng nakakonektang cable sa loob ng 70 m sa pagitan ng distribution board at ng pinakamalayong socket outlet.
  • Gamitin ang nakalistang 100 A gG short-circuit back-up fuse.

FAQ

What distinguishes the VAF3-40M?

The catalog identifies the VAF3-40M as the magnetic version of the arc fault detection device.

Which protection functions are integrated?

Pinagsasama nito ang arc-fault detection sa Type A residual-current, sobrang karga, at short circuit protection.

Anong mga rated current at tripping characteristic ang available?

Nakalista sa catalog ang mga rating na 6, 10, 13, 16, 20, 25, 32, at 40 A na may B o C overcurrent tripping characteristics.

Anong mga residual current sensitivity ang inaalok?

The VAF3-40M provides Type A residual-current protection with 10 mA or 30 mA sensitivity.

What is the rated short-circuit current?

Ang rated short-circuit current ay 6 kA.

Which standards are listed for the VAF3-40M?

Ang mga naaangkop na pamantayan ay IEC/EN 61009-1 at IEC/EN 62606.