VIOX Electric
Language

VAF1-40 Arc Fault Detection Device

The VIOX VAF1-40 arc fault detection device combines arc-fault detection with Type A residual-current, overload and short-circuit protection. Designed for 240 V AC, 50 Hz final circuits, it is available in 6-40 A ratings, B or C tripping characteristics and 10 or 30 mA residual-current sensitivities. Its 1P+N configuration supports residential and commercial electrical installations.

Na-rate na Kasalukuyan
6-40 A
Residual Current
10, 30 mA
Tripping Characteristic
B, C
Short-Circuit Current
6 kA

Pangkalahatang-ideya

The VAF1-40 is an arc fault detection device combining arc-fault detection with Type A residual-current, overload and short-circuit protection. Designed for AC 50 Hz final circuits, it has a rated voltage of 240 V AC and is available in rated currents from 6 A to 40 A. The 1P+N device offers B or C overcurrent tripping characteristics and 10 mA or 30 mA residual-current sensitivities. It is intended for residential and commercial electrical installations requiring combined protection against electrical fires, electric shock and overcurrent faults.

Mga tampok

  • Integrated arc-fault, Type A residual-current, overload and short-circuit protection.
  • Compliant with IEC/EN 61009-1 and IEC/EN 62606.
  • Rated-current options from 6 A to 40 A.
  • B and C overcurrent tripping characteristics.
  • 10 mA and 30 mA residual-current sensitivities.
  • Load-disconnect contact with 6 kA rated short-circuit current.

Mga pagtutukoy

Datos Elektrikal

Parameter Pagtutukoy
Rated current (In) 6, 10, 13, 16, 20, 25, 32, 40 A
Rated voltage (Ue) 240 V AC
Daloy ng paggana 50 Hz
Minimum test-circuit operating voltage 196 V
Maximum test-circuit operating voltage 253 V
Rated na boltahe ng pagkakabukod (Ui) 250 V
Na-rate na impulse withstand boltahe (Uimp) 4 kV
Rated short-circuit current 6 kA
Maximum total rated switching capacity 6 kA
Surge-current withstand strength 0.25 kA
Power loss per current path 3 W
Short-circuit back-up fuse (SCPD) 100 A
Back-up fuse type gG
Kategorya ng overvoltage III

Data ng Proteksiyon

Parameter Pagtutukoy
Product configuration AFDD with integrated Type A residual-current, overload and short-circuit protection
Bilang ng mga poste 1P+N
Uri ng natitirang agos Uri A
Rated residual operating current (IΔn) 10, 30 mA
Overcurrent tripping characteristic B, C
Load-circuit specification Load-disconnect contact

Data ng instalasyon

Parameter Pagtutukoy
Uri ng terminal Screw-type terminals; top or bottom connection on the load circuit
Neutral conductor position Left or right
Maximum connected cable length 70 m between the distribution board and the furthest socket outlet
Terminal clamping capacity 1-25 mm²
Terminal tightening torque 2-2.4 N·m

Standards Data

Parameter Pagtutukoy
Mga naaangkop na pamantayan IEC/EN 61009-1; IEC/EN 62606

Gabay sa Pagpili

Posisyon ng code Ibig sabihin Catalog reference
V Pagkakakilanlan ng negosyo ng VIOX V
AF Arc-fault protection product family AF
1 Serial number ng disenyo 1
40 Maximum frame current 40
C16 C tripping characteristic and rated current 16 A
A30 Ang Type A residual-current protection 30 mA

Na-rate na Kasalukuyan

Select a listed rating from 6 A to 40 A to match the final-circuit rating.

Tripping Characteristic

Select a B or C overcurrent tripping characteristic according to the circuit requirements.

Residual Sensitivity

Select a Type A residual operating-current sensitivity of 10 mA or 30 mA.

Mga application

  • Residential final circuits.
  • Commercial final circuits.
  • Circuits requiring arc-fault and electrical-fire protection.
  • Circuits requiring combined residual-current and overcurrent protection.

Pag-install

  • Use screw-type terminals with top or bottom connection on the load circuit.
  • Confirm whether the selected configuration places the neutral conductor on the left or right.
  • Use conductors within the listed terminal clamping capacity of 1-25 mm².
  • Apply the listed terminal tightening torque of 2-2.4 N·m.
  • Keep the connected cable length within 70 m between the distribution board and the furthest socket outlet.
  • Use the listed 100 A gG short-circuit back-up fuse.

FAQ

Which protection functions are integrated into the VAF1-40?

It combines arc-fault detection with Type A residual-current, overload and short-circuit protection.

Which rated currents and tripping characteristics are available?

The catalog lists 6, 10, 13, 16, 20, 25, 32 and 40 A ratings with B or C overcurrent tripping characteristics.

Which residual-current sensitivities are offered?

The VAF1-40 provides Type A residual-current protection with 10 mA or 30 mA sensitivity.

What is the VAF1-40 rated short-circuit current?

The rated short-circuit current is 6 kA.

What is the maximum connected cable length?

The catalog specifies a maximum of 70 m between the distribution board and the furthest socket outlet.

Which standards are listed for the VAF1-40?

The applicable standards are IEC/EN 61009-1 and IEC/EN 62606.

Kailangan ng Product Quote?
Buuin Natin Ito nang Magkasama.

Ipadala sa amin ang modelo ng produkto, mga teknikal na rating, dami, at mga kinakailangan ng OEM. Susuriin ng aming koponan ang iyong aplikasyon at tutugon sa loob ng isang araw ng negosyo.

Humiling ng Quote