VIOX ELECTRIC
Idioma

Relé Temporizador Fabricante (FCT18 18 mm DIN-Rail · AC/DC 12–240 V · 16 A)

Factory-direct slim 18 mm DIN-rail timer relays across single-function (On-Delay, Off-Delay, Interval, Flashing, Bistable), Star-Delta, Pump Alternation, and Multifunction models—built with crystal-stabilized 0.5% MCU accuracy and 1×/2× SPDT 16 A contacts.

AC/DC 12–240 VUniversal wide-voltage supply
16 A · SPDT / DPDT0.5% MCU accuracy · 18 mm width
Full FCT18 FamilySingle, Star-Delta, RL & Multifunction
VIOX FCT18 18mm DIN-rail timer relay on white studio background

VIOX FCT18 DIN-Rail Timer Relay Series

VIOX FCT18-Q Single-Function On-Delay Timer Relay
Atraso

FCT18-Q

VIOX FCT18-Q Single-Function On-Delay Timer Relay

Função
On-Delay (Power)
Gatilho
Supply A1–A2
Alimentação
AC/DC 12–240 V
Saída
16 A · 1×/2× SPDT
Relé temporizador de intervalo único VIOX ELECTRIC FCT18-BR
Intervalo Único

FCT18-BR

Relé temporizador de intervalo único VIOX ELECTRIC FCT18-BR

Função
Intervalo Único
Gatilho
Supply A1–A2 / S
Alimentação
AC/DC 12–240 V
Saída
16 A · 1×/2× SPDT
Relé temporizador de pulso VIOX ELECTRIC FCT18-AR
Pulso Atrasado

FCT18-AR

Relé temporizador de pulso VIOX ELECTRIC FCT18-AR

Função
Delayed One-Shot
Gatilho
Supply / Control S
Alimentação
AC/DC 12–240 V
Saída
16 A · 1×/2× SPDT
Relé de temporização de intermitência assimétrica VIOX FCT18-BcR
Asym. Flashing

FCT18-BCR

Relé de temporização de intermitência assimétrica VIOX FCT18-BcR

Função
Asymmetrical Cyclic
Gatilho
Supply A1–A2
Alimentação
AC/DC 12–240 V
Saída
16 A · 1×/2× SPDT
Relé temporizador de intervalo duplo VIOX ELECTRIC FCT18-BD
Intervalo Duplo

FCT18-BD

Relé temporizador de intervalo duplo VIOX ELECTRIC FCT18-BD

Função
Rising + Falling Pulse
Gatilho
Control Signal S
Alimentação
AC/DC 12–240 V
Saída
16 A · 1×/2× SPDT
VIOX FCT18-WgR Asymmetrical On & Off Delay Timer
On + Off Delay

FCT18-WGR

VIOX FCT18-WgR Asymmetrical On & Off Delay Timer

Função
Independent t1 & t2
Gatilho
Control Signal S
Alimentação
AC/DC 12–240 V
Saída
16 A · 1×/2× SPDT
VIOX FCT18-ST Star-Delta Timer Relay
Chave de Partida Estrela-Triângulo

FCT18-ST

VIOX FCT18-ST Star-Delta Timer Relay

Função
Star-Delta Transfer
Gatilho
Supply A1–A2
Alimentação
AC/DC 12–240 V
Saída
2× SPDT (Y/Δ Delay)
Relé do temporizador de alternância VIOX FCT18-RL
Alternância de Bombas

FCT18-RL

Relé do temporizador de alternância VIOX FCT18-RL

Função
Duty / Standby Swap
Gatilho
Control Signal S
Alimentação
AC/DC 12–240 V
Saída
2× SPDT Alternator
Relé temporizador multifunções VIOX FCT18-M
Multifunções

FCT18-M

Relé temporizador multifunções VIOX FCT18-M

Função
10-Function Dial
Gatilho
Supply / Control S
Alimentação
AC/DC 12–240 V
Saída
16 A · 1×/2× SPDT
Relé temporizador multifunções VIOX FCT18-N
Multifunções

FCT18-N

Relé temporizador multifunções VIOX FCT18-N

Função
Multi-Mode Control
Gatilho
Supply / Control S
Alimentação
AC/DC 12–240 V
Saída
16 A · 1×/2× SPDT
Relé temporizador multifunções VIOX FCT18-X
Multifunções

FCT18-X

Relé temporizador multifunções VIOX FCT18-X

Função
Extended Multi-Mode
Gatilho
Supply / Control S
Alimentação
AC/DC 12–240 V
Saída
16 A · 1×/2× SPDT
Interactive Timing Diagram Explorer

Inspect All 8 Core FCT18 Timing Diagrams (Power U · Trigger S · Output R)

FCT18-Q — On-Delay Timer Relay

View Model Datasheet →
Terminal Wiring & Contact Derating

FCT18 18 mm Terminal Layout (A1/A2/S · 15-16-18) & SPDT vs. DPDT

Standardized DIN-rail terminal numbering ensures fast panel wiring and drop-in replacement of legacy 18 mm timers.

FCT18 Standard Terminal Wiring (18 mm DIN Rail) VIOX FCT18 AC/DC 12–240 V · 0.5% A1 S A2 15 16 18 A1 / A2: AC/DC 12–240 V Fonte de alimentação S (Control Input): External switch / PLC (BTA / BD / CR / WGR) 15 = Common (COM) · 16 = Normally Closed (NC) · 18 = Normally Open (NO) · 2nd pole (DPDT): 25-26-28

1×SPDT (1CO) vs. 2×SPDT (DPDT) Output

Utilização 1×SPDT for single-load timing; specify 2×SPDT (DPDT) when one timer must switch a main load and send an isolated 24 V DC PLC signal simultaneously (SPDT vs. DPDT Guide →).

16 A Resistive vs. Inductive Contactor Coils

16 A is rated for AC-1 resistive loads. When switching inductive AC contactor coils or compressors, derate to 3–5 A AC-15 and fit an RC snubber across the coil to maximize contact life.

Complete Multi-Mode Wiring Diagrams

Need full schematics for pump alternation, HVAC anti-short-cycle, or PLC handshakes? See our Time Delay Relay Wiring Diagram Guide →.

Why Low-Cost Timer Relays Fail in Control Panels — And How FCT18 Solves It

Timing errors in HVAC, pumping, and sequential machinery trigger expensive downtime and compressor burnouts.

01EMC Surge

Wide-Voltage Power Board Burnout

Poorly filtered 12–240 V AC/DC front-ends blow out when VFDs or contactors inject switching transients onto the control bus.

FCT18 FixIndustrial wide-voltage AC/DC 12–240 V input stage verified under EMC & transient surge checks.
02Clock Drift

Analog RC Drift Over Temperature

Cheap RC-capacitor timers drift by ±10%–15% inside warm cabinets, throwing off sequential motor starts and dosing intervals.

FCT18 FixCrystal-stabilized MCU timing holding 0.5% setting accuracy across operating temperatures.
03Wrong Edge

Wrong Trigger Edge (Power vs. S)

Ordering a power-triggered On-Delay when the panel needs a continuous-power Off-Delay forces last-minute rewiring at FAT.

FCT18 FixDedicated single-function & multifunction SKUs with clear front-panel timing diagrams.
04Contact Weld

Contact Welding on High-Inrush Loads

Undersized 5 A / 8 A relays weld shut when switching transformer primaries, LED banks, or heavy solenoid valves.

FCT18 FixHeavy-duty 16 A changeover contacts in a slim 18 mm modular DIN-rail body.

FCT18 Application Selection Matrix & Tier-1 Cross-Reference

Map your control logic to the exact FCT18 model, verify electrical boundaries, and compare against global 18 mm automation references.

FCT18 application-to-model decision matrix with explicit engineering limits
Control Application Recommended FCT18 Trigger & Output Engineering Limit / Not Suitable For Pre-Order Verification
Sequential Motor / HVAC Compressor Start FCT18-Q Power (A1–A2) · 16 A SPDT 16 A resistive max — pair with Contator AC ou Contator Modular for heavy motors. Confirm staggered delay band & supply voltage.
Exhaust Fan Run-On & Staircase Lighting FCT18-BTA Control Signal (S) · Falling Edge Requires continuous power on A1–A2 during off-delay countdown (not a true power-off memory timer). Verify S-terminal trigger voltage matches A1–A2 supply.
Timed Dosing, Heater & Alarm Pulse FCT18-BR / FCT18-AR Power (A1–A2) · Timed Pulse Mechanical relay output — not for high-frequency (> 1 Hz) solid-state PWM switching. Confirm immediate pulse (BR) vs. delayed pulse (AR).
Intermittent Lubrication, Beacons & Aeration FCT18-BCR Power (A1–A2) · Asymmetrical Cyclic Independent ON/OFF pots set by dial; for Modbus-logged schedules use a PLC instead. Confirm t1 (OFF) and t2 (ON) independent range bands.
Level-Switch Debounce + Pump Overrun FCT18-WGR Control Signal (S) · On + Off Delay Dual-delay calibration requires verifying t1 (debounce) and t2 (run-on) separately at FAT. Confirm 1×SPDT vs. 2×SPDT (DPDT) load isolation need.
Star-Delta Motor Starting & Pump Alternation FCT18-ST / FCT18-RL 2× SPDT Dedicated Logic Verify star-to-delta dead-time transition window (e.g., 40–100 ms) to prevent phase shorting. Confirm motor contactor coil voltage & interlocks.
Benchmark of VIOX FCT18 against Finder 80, Schneider Zelio RE17, Omron H3DK, and ABB CT-D
Dimensão de avaliação Tier-1 Reference (Finder 80 / Zelio RE17 / Omron H3DK / ABB CT-D) VIOX FCT18 Platform Commercial & OEM Delta
Enclosure & Terminals 17.5–18 mm DIN rail · A1/A2/S · 15-16-18 18 mm DIN rail · Standard A1/A2/S & 15-16-18 Drop-in mechanical & wiring footprint inside IEC panels
Supply & Output 12–240 V AC/DC · 8 A–16 A SPDT/DPDT AC/DC 12–240 V · 16 A (1×/2× SPDT) · 0.5% accuracy 45%–65% lower landed BOM cost for OEMs & distributors
OEM Dial & Private Label Not offered to regional automation brands Custom Front Dial, Laser Logo & Packaging Mix single, star-delta & multifunction models on 1 PO

Onde isso realmente se encaixa

If an export control panel legally mandates sole-source UL-Listed Finder, Omron H3DK, or Schneider Zelio RE17 with zero equivalents allowed, stay with that Tier-1 unit. Where IEC 61812-1 / CE industrial specifications govern—and you need 0.5% MCU accuracy, 16 A output in an 18 mm body, 45%–65% BOM savings, and OEM private-label customization—VIOX FCT18 is engineered to be your direct factory platform.

Direct Factory Proof · Timer Relay Manufacturer

Inside VIOX FCT18 Manufacturing, 100% QC & OEM Customization

Direct factory production in Yueqing/Wenzhou for global electrical distributors, machine builders, and private-label automation brands—with verifiable IEC 61812-1 batch testing and full OEM customization.

010.5% Clock QC

MCU Clock Calibration

Automated timing-accuracy check across short (0.1 s) and extended delay bands before final ultrasonic housing closure.

OEM CustomFront-panel silkscreen, private-label brand logo & custom model codes on the 18 mm fascia.
02EMC & Surge

12–240 V AC/DC EMC Check

Wide-voltage SMPS power stages verified for brownout recovery and industrial contactor switching noise immunity.

OEM CustomDedicated AC 230 V, DC 24 V, or universal AC/DC 12–240 V builds with custom delay scale bands.
0316 A Contact

Relay Contact & Hi-Pot QC

Contact resistance, dielectric isolation (A1/A2 to 15-16-18), and mechanical cycle checks executed on every batch.

OEM CustomPrivate-label color boxes, EAN/UPC barcodes, multilingual wiring leaflets & master-carton marks.
04IEC 61812-1

Traceability & Burn-In

Lot-coded PCBA inspection, thermal soak verification, and batch test records retained per export purchase order.

One-PO KittingConsolidate FCT18 with VIOX MCB, Contator Modular & ATS.

Sourcing Mixed-Function FCT18 Orders or OEM Private-Label Timers?

Mix single-function, star-delta, alternation, and multifunction FCT18 models in one factory shipment—request validation samples and OEM pricing.

Request OEM Timer Quote →
5-Step Spec & RFQ Builder

Match Your Exact FCT18 Model & Generate an OEM Spec Brief

FCT18 Timer Relay Selection & Sourcing Questions

Direct answers on power vs. S-terminal triggering, 16 A inductive derating, SPDT/DPDT contacts, Tier-1 compatibility, and OEM supply.

Acionamento What is the difference between power-triggered and control-signal (S terminal) FCT18 timer relays?

Power-triggered models (FCT18-Q On-Delay, FCT18-BR Single Interval, FCT18-BCR Flashing) start timing immediately when voltage is applied to terminals A1–A2.

Control-signal models (FCT18-BTA Off-Delay, FCT18-BD Double Interval, FCT18-CR Bistable, FCT18-WGR) require continuous power on A1–A2 and trigger timing from an external switch or PLC signal on terminal S.

Load Duty Can a 16 A FCT18 timer relay switch AC contactor coils or motors directly?

The 16 A rating applies to resistive AC-1 loads (250 V AC). For inductive loads such as AC contactor coils, solenoids, or fractional-HP motors, derate the output contact (typically 3–5 A AC-15) and install an RC snubber or varistor across the inductive coil to prevent contact arcing.

Contactos When should I specify 2×SPDT (DPDT) instead of 1×SPDT on an FCT18 timer relay?

Choose 1×SPDT (1CO: 15-16-18) for single-circuit delayed switching. Specify 2×SPDT (DPDT: 2CO) when one timing sequence must simultaneously switch two electrically isolated circuits—such as energizing a 230 V AC contactor while sending a separate 24 V DC status signal to a PLC.

Cross-Ref Are VIOX FCT18 18 mm timer relays mechanically compatible with Schneider Zelio RE17, Finder 80, or ABB CT-D?

Yes. FCT18 uses the universal 18 mm modular DIN-rail width (EN 60715 TS35), standard A1/A2/S control terminals, and 15-16-18 changeover contacts for clean drop-in panel replacement.

Always verify the exact timing diagram and control-signal voltage compatibility before substituting.

Factory QC How does VIOX verify 0.5% setting accuracy and 12–240 V wide-voltage stability?

Every FCT18 production batch uses crystal-stabilized MCU timing architecture and undergoes automated timing-accuracy checks, 12–240 V AC/DC wide-voltage EMC/surge testing, and 16 A relay contact resistance & Hi-Pot inspection before packing.

OEM / MOQ Does VIOX support OEM front-panel dial customization, laser marking, and mixed-function FCT18 orders?

Yes. Distributors and automation OEMs can mix single-function, star-delta, alternation, and multifunction FCT18 models in one factory order—with custom front silkscreen, laser logos, multilingual leaflets, and private-label inner boxes.

Need the Right DIN-Rail Timer Relay?
Vamos confirmar juntos.

Send your timing function, delay range, supply voltage (12–240 V AC/DC), contact type (SPDT/DPDT), and quantity. VIOX engineers will match the right FCT18 model.

Request Timer Relay Quote