Relé Temporizador Fabricante (FCT18 18 mm DIN-Rail · AC/DC 12–240 V · 16 A)
Factory-direct slim 18 mm DIN-rail timer relays across single-function (On-Delay, Off-Delay, Interval, Flashing, Bistable), Star-Delta, Pump Alternation, and Multifunction models—built with crystal-stabilized 0.5% MCU accuracy and 1×/2× SPDT 16 A contacts.
VIOX FCT18 DIN-Rail Timer Relay Series
FCT18-Q
VIOX FCT18-Q Single-Function On-Delay Timer Relay
- Função
- On-Delay (Power)
- Gatilho
- Supply A1–A2
- Alimentação
- AC/DC 12–240 V
- Saída
- 16 A · 1×/2× SPDT
FCT18-BTA
VIOX FCT18-Bta Off-Delay Timer Relay
- Função
- Off-Delay (Summation)
- Gatilho
- Control Signal S
- Alimentação
- AC/DC 12–240 V
- Saída
- 16 A · 1×/2× SPDT
FCT18-BR
Relé temporizador de intervalo único VIOX ELECTRIC FCT18-BR
- Função
- Intervalo Único
- Gatilho
- Supply A1–A2 / S
- Alimentação
- AC/DC 12–240 V
- Saída
- 16 A · 1×/2× SPDT
FCT18-AR
Relé temporizador de pulso VIOX ELECTRIC FCT18-AR
- Função
- Delayed One-Shot
- Gatilho
- Supply / Control S
- Alimentação
- AC/DC 12–240 V
- Saída
- 16 A · 1×/2× SPDT
FCT18-BCR
Relé de temporização de intermitência assimétrica VIOX FCT18-BcR
- Função
- Asymmetrical Cyclic
- Gatilho
- Supply A1–A2
- Alimentação
- AC/DC 12–240 V
- Saída
- 16 A · 1×/2× SPDT
FCT18-BD
Relé temporizador de intervalo duplo VIOX ELECTRIC FCT18-BD
- Função
- Rising + Falling Pulse
- Gatilho
- Control Signal S
- Alimentação
- AC/DC 12–240 V
- Saída
- 16 A · 1×/2× SPDT
FCT18-CR
VIOX FCT18-CR Bistable Timer Relay
- Função
- Impulse / Toggle
- Gatilho
- Control Signal S
- Alimentação
- AC/DC 12–240 V
- Saída
- 16 A · 1×/2× SPDT
FCT18-WGR
VIOX FCT18-WgR Asymmetrical On & Off Delay Timer
- Função
- Independent t1 & t2
- Gatilho
- Control Signal S
- Alimentação
- AC/DC 12–240 V
- Saída
- 16 A · 1×/2× SPDT
FCT18-ST
VIOX FCT18-ST Star-Delta Timer Relay
- Função
- Star-Delta Transfer
- Gatilho
- Supply A1–A2
- Alimentação
- AC/DC 12–240 V
- Saída
- 2× SPDT (Y/Δ Delay)
FCT18-RL
Relé do temporizador de alternância VIOX FCT18-RL
- Função
- Duty / Standby Swap
- Gatilho
- Control Signal S
- Alimentação
- AC/DC 12–240 V
- Saída
- 2× SPDT Alternator
FCT18-M
Relé temporizador multifunções VIOX FCT18-M
- Função
- 10-Function Dial
- Gatilho
- Supply / Control S
- Alimentação
- AC/DC 12–240 V
- Saída
- 16 A · 1×/2× SPDT
FCT18-N
Relé temporizador multifunções VIOX FCT18-N
- Função
- Multi-Mode Control
- Gatilho
- Supply / Control S
- Alimentação
- AC/DC 12–240 V
- Saída
- 16 A · 1×/2× SPDT
FCT18-X
Relé temporizador multifunções VIOX FCT18-X
- Função
- Extended Multi-Mode
- Gatilho
- Supply / Control S
- Alimentação
- AC/DC 12–240 V
- Saída
- 16 A · 1×/2× SPDT
Inspect All 8 Core FCT18 Timing Diagrams (Power U · Trigger S · Output R)
FCT18-Q — On-Delay Timer Relay
View Model Datasheet →FCT18 18 mm Terminal Layout (A1/A2/S · 15-16-18) & SPDT vs. DPDT
Standardized DIN-rail terminal numbering ensures fast panel wiring and drop-in replacement of legacy 18 mm timers.
1×SPDT (1CO) vs. 2×SPDT (DPDT) Output
Utilização 1×SPDT for single-load timing; specify 2×SPDT (DPDT) when one timer must switch a main load and send an isolated 24 V DC PLC signal simultaneously (SPDT vs. DPDT Guide →).
16 A Resistive vs. Inductive Contactor Coils
16 A is rated for AC-1 resistive loads. When switching inductive AC contactor coils or compressors, derate to 3–5 A AC-15 and fit an RC snubber across the coil to maximize contact life.
Complete Multi-Mode Wiring Diagrams
Need full schematics for pump alternation, HVAC anti-short-cycle, or PLC handshakes? See our Time Delay Relay Wiring Diagram Guide →.
Why Low-Cost Timer Relays Fail in Control Panels — And How FCT18 Solves It
Timing errors in HVAC, pumping, and sequential machinery trigger expensive downtime and compressor burnouts.
Wide-Voltage Power Board Burnout
Poorly filtered 12–240 V AC/DC front-ends blow out when VFDs or contactors inject switching transients onto the control bus.
Analog RC Drift Over Temperature
Cheap RC-capacitor timers drift by ±10%–15% inside warm cabinets, throwing off sequential motor starts and dosing intervals.
Wrong Trigger Edge (Power vs. S)
Ordering a power-triggered On-Delay when the panel needs a continuous-power Off-Delay forces last-minute rewiring at FAT.
Contact Welding on High-Inrush Loads
Undersized 5 A / 8 A relays weld shut when switching transformer primaries, LED banks, or heavy solenoid valves.
FCT18 Application Selection Matrix & Tier-1 Cross-Reference
Map your control logic to the exact FCT18 model, verify electrical boundaries, and compare against global 18 mm automation references.
| Control Application | Recommended FCT18 | Trigger & Output | Engineering Limit / Not Suitable For | Pre-Order Verification |
|---|---|---|---|---|
| Sequential Motor / HVAC Compressor Start | FCT18-Q | Power (A1–A2) · 16 A SPDT | 16 A resistive max — pair with Contator AC ou Contator Modular for heavy motors. | Confirm staggered delay band & supply voltage. |
| Exhaust Fan Run-On & Staircase Lighting | FCT18-BTA | Control Signal (S) · Falling Edge | Requires continuous power on A1–A2 during off-delay countdown (not a true power-off memory timer). | Verify S-terminal trigger voltage matches A1–A2 supply. |
| Timed Dosing, Heater & Alarm Pulse | FCT18-BR / FCT18-AR | Power (A1–A2) · Timed Pulse | Mechanical relay output — not for high-frequency (> 1 Hz) solid-state PWM switching. | Confirm immediate pulse (BR) vs. delayed pulse (AR). |
| Intermittent Lubrication, Beacons & Aeration | FCT18-BCR | Power (A1–A2) · Asymmetrical Cyclic | Independent ON/OFF pots set by dial; for Modbus-logged schedules use a PLC instead. | Confirm t1 (OFF) and t2 (ON) independent range bands. |
| Level-Switch Debounce + Pump Overrun | FCT18-WGR | Control Signal (S) · On + Off Delay | Dual-delay calibration requires verifying t1 (debounce) and t2 (run-on) separately at FAT. | Confirm 1×SPDT vs. 2×SPDT (DPDT) load isolation need. |
| Star-Delta Motor Starting & Pump Alternation | FCT18-ST / FCT18-RL | 2× SPDT Dedicated Logic | Verify star-to-delta dead-time transition window (e.g., 40–100 ms) to prevent phase shorting. | Confirm motor contactor coil voltage & interlocks. |
| Dimensão de avaliação | Tier-1 Reference (Finder 80 / Zelio RE17 / Omron H3DK / ABB CT-D) | VIOX FCT18 Platform | Commercial & OEM Delta |
|---|---|---|---|
| Enclosure & Terminals | 17.5–18 mm DIN rail · A1/A2/S · 15-16-18 | 18 mm DIN rail · Standard A1/A2/S & 15-16-18 | Drop-in mechanical & wiring footprint inside IEC panels |
| Supply & Output | 12–240 V AC/DC · 8 A–16 A SPDT/DPDT | AC/DC 12–240 V · 16 A (1×/2× SPDT) · 0.5% accuracy | 45%–65% lower landed BOM cost for OEMs & distributors |
| OEM Dial & Private Label | Not offered to regional automation brands | Custom Front Dial, Laser Logo & Packaging | Mix single, star-delta & multifunction models on 1 PO |
Onde isso realmente se encaixa
If an export control panel legally mandates sole-source UL-Listed Finder, Omron H3DK, or Schneider Zelio RE17 with zero equivalents allowed, stay with that Tier-1 unit. Where IEC 61812-1 / CE industrial specifications govern—and you need 0.5% MCU accuracy, 16 A output in an 18 mm body, 45%–65% BOM savings, and OEM private-label customization—VIOX FCT18 is engineered to be your direct factory platform.
Inside VIOX FCT18 Manufacturing, 100% QC & OEM Customization
Direct factory production in Yueqing/Wenzhou for global electrical distributors, machine builders, and private-label automation brands—with verifiable IEC 61812-1 batch testing and full OEM customization.
MCU Clock Calibration
Automated timing-accuracy check across short (0.1 s) and extended delay bands before final ultrasonic housing closure.
12–240 V AC/DC EMC Check
Wide-voltage SMPS power stages verified for brownout recovery and industrial contactor switching noise immunity.
Relay Contact & Hi-Pot QC
Contact resistance, dielectric isolation (A1/A2 to 15-16-18), and mechanical cycle checks executed on every batch.
Traceability & Burn-In
Lot-coded PCBA inspection, thermal soak verification, and batch test records retained per export purchase order.
Sourcing Mixed-Function FCT18 Orders or OEM Private-Label Timers?
Mix single-function, star-delta, alternation, and multifunction FCT18 models in one factory shipment—request validation samples and OEM pricing.
Match Your Exact FCT18 Model & Generate an OEM Spec Brief
Timer relay engineering knowledge center
Wiring schematics, timing-mode breakdowns, and troubleshooting guides written for panel builders and control engineers.
Time Delay Relay Wiring Diagram Guide: On-Delay, Off-Delay & Controls
Ler o guia →Timer Relay Function Modes Explained: On-Delay, Off-Delay, Interval & Flasher
Ler o guia →Por que seu relé temporizador se autoativa: Corrente de fuga na entrada de controle
Ler o guia →Multifunction vs. Single-Function Timer Relay: Which One Should You Choose?
Ler o guia →12 V vs. 24 V vs. 120 V vs. 230 V Timer Relay: Supply Voltage Guide
Ler o guia →Como Calcular o Intervalo de Tempo Correto para o Seu Relé Temporizador
Ler o guia →FCT18 Timer Relay Selection & Sourcing Questions
Direct answers on power vs. S-terminal triggering, 16 A inductive derating, SPDT/DPDT contacts, Tier-1 compatibility, and OEM supply.
Acionamento What is the difference between power-triggered and control-signal (S terminal) FCT18 timer relays?
Power-triggered models (FCT18-Q On-Delay, FCT18-BR Single Interval, FCT18-BCR Flashing) start timing immediately when voltage is applied to terminals A1–A2.
Control-signal models (FCT18-BTA Off-Delay, FCT18-BD Double Interval, FCT18-CR Bistable, FCT18-WGR) require continuous power on A1–A2 and trigger timing from an external switch or PLC signal on terminal S.
Load Duty Can a 16 A FCT18 timer relay switch AC contactor coils or motors directly?
The 16 A rating applies to resistive AC-1 loads (250 V AC). For inductive loads such as AC contactor coils, solenoids, or fractional-HP motors, derate the output contact (typically 3–5 A AC-15) and install an RC snubber or varistor across the inductive coil to prevent contact arcing.
Contactos When should I specify 2×SPDT (DPDT) instead of 1×SPDT on an FCT18 timer relay?
Choose 1×SPDT (1CO: 15-16-18) for single-circuit delayed switching. Specify 2×SPDT (DPDT: 2CO) when one timing sequence must simultaneously switch two electrically isolated circuits—such as energizing a 230 V AC contactor while sending a separate 24 V DC status signal to a PLC.
Cross-Ref Are VIOX FCT18 18 mm timer relays mechanically compatible with Schneider Zelio RE17, Finder 80, or ABB CT-D?
Yes. FCT18 uses the universal 18 mm modular DIN-rail width (EN 60715 TS35), standard A1/A2/S control terminals, and 15-16-18 changeover contacts for clean drop-in panel replacement.
Always verify the exact timing diagram and control-signal voltage compatibility before substituting.
Factory QC How does VIOX verify 0.5% setting accuracy and 12–240 V wide-voltage stability?
Every FCT18 production batch uses crystal-stabilized MCU timing architecture and undergoes automated timing-accuracy checks, 12–240 V AC/DC wide-voltage EMC/surge testing, and 16 A relay contact resistance & Hi-Pot inspection before packing.
OEM / MOQ Does VIOX support OEM front-panel dial customization, laser marking, and mixed-function FCT18 orders?
Yes. Distributors and automation OEMs can mix single-function, star-delta, alternation, and multifunction FCT18 models in one factory order—with custom front silkscreen, laser logos, multilingual leaflets, and private-label inner boxes.
Need the Right DIN-Rail Timer Relay?
Vamos confirmar juntos.
Send your timing function, delay range, supply voltage (12–240 V AC/DC), contact type (SPDT/DPDT), and quantity. VIOX engineers will match the right FCT18 model.
Request Timer Relay Quote