DC Surge Protective Device (DC SPD) 600V, 1000V, 1500V & 2000V DC · Type 1+2 & Type 2 Solar PV Arresters
Engineered exclusively for high-voltage DC solar combiner boxes, string inverters, and BESS DC buses. VIOX builds fault-tolerant Type Y (3P) and compact Type U (2P) DC SPDs with dedicated DC arc-quenching disconnectors—covering VSP-15T/G1000–G1500 (Type 1+2) and VSP-40/G600–G2000 (Type 2). Looking for AC distribution SPDs? Visit our AC & Full SPD Hub →.
VIOX Solar PV DC SPD Series (Type 1+2 & Type 2)
Both master series include pluggable DC MOV cartridges, visual status flags, optional 11/12/14 remote alarm contacts, and full CAD dimensional drawings.
VIOX VSP-40/G600 – G2000
Solar PV DC Type 2 · 600V–2000V- Série VIOX
- VSP-40/G600 – G2000
- Tensão nominal
- 600V / 1000V / 1500V / 2000V DC
- Surge Rating
- In 20 kA · Imax 40 kA (8/20μs)
- Padrão
- IEC 61643-31 · EN 50539-11 · TUV / CE
VIOX VSP-15T/G1000 / G1500
Solar PV DC Type 1+2 · 1000V / 1500V- Série VIOX
- VSP-15T/G1000 / G1500
- Tensão nominal
- 1000V DC / 1500V DC
- Surge Rating
- Iimp 6.25 kA (10/350μs) · Imax 40 kA
- Padrão
- IEC 61643-31 · T1+T2 PV · CE / CB
Compare All 6 DC SPD Voltage & IEC Class Configurations
Match your string cold-temperature Voc, external lightning protection (LPS) status, and combiner-box DIN width.
| Modelo VIOX | IEC 61643-31 Class | Ucpv / Surge Rating / Up | Topology & Width | Folha de dados |
|---|---|---|---|---|
| VSP-15T/G1000 | PV Type 1+2 (10/350 + 8/20) | 1000 V DC · Iimp 6.25 kA · Imax 40 kA · Up 3.5 kV | Type Y (3P) · 108 × 90 × 72 mm | View VSP-15T → |
| VSP-15T/G1500 | PV Type 1+2 (10/350 + 8/20) | 1500 V DC · Iimp 6.25 kA · Imax 40 kA · Up 5.5 kV | Type Y (3P) · 108 × 90 × 72 mm | View VSP-15T → |
| VSP-40/G600 | PV Type 2 (8/20µs) | 600 V DC · In 20 kA · Imax 40 kA · Up 3.0 kV | Type U (36 mm) / Type Y (54 mm) | View VSP-40 PV → |
| VSP-40/G1000 | PV Type 2 (8/20µs) | 1000 V DC · In 20 kA · Imax 40 kA · Up 3.5 kV | Type U (36 mm) / Type Y (54 mm) | View VSP-40 PV → |
| VSP-40/G1500 | PV Type 2 (8/20µs) | 1500 V DC · In 20 kA · Imax 40 kA · Up 5.5 kV | Type U (54 mm) / Type Y (54–81 mm) | View VSP-40 PV → |
| VSP-40/G2000 | PV Type 2 Next-Gen Utility | 2000 V DC · In 20 kA · Imax 40 kA · Up 6.5 kV | Type Y (3P) · 81 × 90 × 67 mm | View VSP-40 PV → |
Interactive PV Cold-Site Voc & LPS DC SPD Selector
Select your solar string DC bus voltage and external lightning protection (LPS) status to match the exact VIOX DC SPD model and wiring rule.
1. Solar String / BESS Nominal DC Voltage
2. External Lightning Protection (LPS) Exposure
Type Y (3P) vs. Type U (2P) DC Wiring & 4 PV Failure Modes
Understand why floating solar arrays require Type Y fault-tolerant MOV circuits and why AC SPDs ignite on DC faults.
Rule 1 · Dedicated DC Arc Quenching Is Mandatory
DC current never crosses zero. VIOX VSP-15T and VSP-40 PV cartridges use spring-assisted DC arc-extinguishing disconnectors tested to IEC 61643-31.
Rule 2 · Specify Type Y (3P) for Floating Solar Strings
Type Y places two MOV stages across the full DC bus, preventing sustained array short-circuits if one DC pole develops a ground fault in wet rooftop conduit.
Rule 3 · Keep Combiner & Inverter Leads ≤ 0.5 m
Use ≥10 mm² (T2) or ≥16 mm² (T1+2) copper bonding cable directly to the combiner box PE rail so inductive voltage drop never breaches inverter impulse limits.
One-PO Solar Combiner & BESS Protection Kitting
Source matched DC SPDs alongside VIOX 1500V DC gPV fuses, DC MCBs, rotary DC isolators, and pre-wired combiner boxes in a single factory shipment.
Fusíveis gPV de 1500V DC
Coordinate string and sub-array overcurrent protection with VIOX VOPV 10×85mm & NH XL solar fuses. Explore Solar PV Fuses →
Disjuntores de corrente contínua
Non-polarized DIN-rail DC MCBs for 500V–1000V DC solar strings and battery storage racks. Explore DC MCBs →
Interruptores de isolador DC
IEC 60947-3 DC-PV2 load-break rotary isolators (1000V/1500V DC) for safe array maintenance. Explore DC Isolators →
AC Side & Combiner Boxes
Complete your inverter AC panel with VIOX AC Type 1+2 / 690V SPDs or pre-assembled Caixas combinadoras fotovoltaicas.
Build Your Solar PV DC SPD RFQ Brief
Configure DC voltage, IEC class, topology, and PV kitting scope to prefill our engineering quotation form in one click.
1. DC Voltage Rating (Ucpv)
2. IEC 61643-31 Class & Topology
3. Remote Alarm & PV Kitting Scope
DC SPD & Solar Combiner Engineering Guides
Verified technical guides on AC vs. DC SPD safety, combiner box wiring diagrams, and IEC 61643-31 compliance.
Solar PV DC SPD Engineering FAQ
Direct answers on DC arc extinction, cold-site Voc sizing, Type 1+2 vs. Type 2 LPS rules, Type Y wiring, and >10 m dual-end protection.
DC Safety Why can an AC SPD never be installed on a 600V, 1000V, or 1500V DC solar PV circuit?
AC current crosses zero 100 or 120 times per second, helping extinguish internal arcs. DC solar string current has no zero-crossing; an AC-rated MOV disconnector cannot interrupt a sustained DC fault arc at end-of-life, creating a severe combiner-box fire hazard.
Always specify IEC 61643-31 / EN 50539-11 DC-rated SPDs such as VIOX VSP-15T/G or VSP-40/G series with dedicated DC arc-quenching thermal disconnectors.
Cold-Site Voc How do I calculate the required Ucpv rating for a solar PV DC SPD?
Solar panel open-circuit voltage (Voc) rises as ambient temperature drops. Select a DC SPD whose maximum continuous operating voltage satisfies Ucpv ≥ 1.2 × Voc_STC (or the exact site cold-temperature corrected Voc_max).
Use VSP-40/G600 for 600 V residential strings, G1000 for 1000 V C&I arrays, G1500 for 1500 V utility arrays, and G2000 for next-generation 2000 V DC utility / BESS architectures.
Type 1+2 vs T2 When does a solar plant require PV Type 1+2 (VSP-15T/G) instead of PV Type 2 (VSP-40/G)?
Install PV Type 1+2 (VSP-15T/G1000 or G1500, Iimp 6.25 kA at 10/350 µs) whenever the building or ground-mount solar plant has an external lightning protection system (LPS) and required separation distance s cannot be maintained.
When no external LPS is present (or full separation distance is maintained), IEC 61643-31 Type 2 (VSP-40/G600–G2000, Imax 40 kA at 8/20 µs) protects against induced switching and indirect lightning surges.
Type U vs Type Y What is the difference between Type U (2P) and Type Y (3P) DC SPD wiring?
A Type Y (3P: DC+ / PE / DC-) PV SPD connects two MOV cartridges in series across DC+ and DC- with a third MOV to PE, making the circuit fault-tolerant so a single insulation failure on one pole cannot short-circuit the solar array.
Type U (2P) is used on compact lower-voltage or grounded-pole DC circuits where 36 mm width is required.
Dual-End Rule Do I need DC SPDs at both the solar combiner box and the inverter DC input?
Yes, whenever the DC cable run between the rooftop or field combiner box and the inverter exceeds 10 meters. Long DC cables act as antennas and introduce voltage reflection; installing matched VIOX DC SPDs at both ends clamps surges safely below the inverter DC withstand limit.
Backup Fuse Does a VIOX PV DC SPD require an external backup fuse?
When the prospective PV array short-circuit current is within the SPD Iscpv rating (500 A on VSP-40/G; 100 A on VSP-15T/G), the internal DC thermal disconnector clears end-of-life faults safely without an external backup fuse. For high-current utility BESS or parallel combiner buses exceeding Iscpv, coordinate upstream with VIOX VOPV 1500V DC gPV fuses.
Sourcing 1000V, 1500V or 2000V DC Solar SPDs?
Send your string Voc, combiner box quantity, Type 1+2 / Type 2 requirement, or OEM label specs for direct factory pricing and CAD drawings.
Request DC SPD Quote →