CTB101015 Ceramiczny blok zacisków
VIOX CTB101015 Ceramic Terminal Block offers a 10-in-10-out, 15A design for maximum high-density multi-circuit needs. With 750°C heat resistance, it’s ideal for automation and telecommunications. Trust VIOX for reliable, space-efficient solutions in extreme industrial environments.
Wyślij swoje wymagania, wycenimy je w ciągu 12 godzin
- TEL:+8618066396588
- Whatsapp:+8618066396588
- Email:sales@viox.com
The CTB101015 Ceramic Terminal Block represents the pinnacle of high-density multi-circuit connection technology, offering unprecedented flexibility for complex electrical systems requiring extensive parallel connections. This professional-grade 10-in-10-out terminal block combines a 15A current rating with superior thermal stability and exceptional electrical insulation properties, making it the definitive choice for engineers and electricians working on highly sophisticated projects requiring numerous medium-current connections with maximum reliability and absolute space efficiency.
Maximum-Capacity Multi-Circuit Design for Advanced Electrical Systems
The CTB101015 features an industry-leading 10-in-10-out configuration specifically engineered to maximize connection capacity while maintaining a practical form factor. Precision-manufactured from high-frequency ceramic material, this terminal block delivers superior insulation properties that significantly outperform conventional plastic alternatives in medium-current, high-temperature environments. The ceramic housing ensures complete resistance to aging, cracking, and deformation even under extreme temperature conditions up to 750°C, guaranteeing long-term stability and safety for your most complex electrical installations.
Each terminal block incorporates twenty precision-engineered connection points with copper core conductors for optimal electrical performance and M3-compatible screw terminals manufactured from durable iron-plated zinc material. This construction provides secure and reliable wire clamping that withstands vibration and thermal cycling without loosening over time, ensuring consistent electrical contact across all ten circuits in demanding applications where connection integrity is critical.
Kluczowe cechy i zalety techniczne
- Maksymalna gęstość połączeń: Ten-in, ten-out design enables highly complex multi-circuit configurations for the most sophisticated electrical systems
- Rozszerzona konfiguracja liniowa: 88mm length provides exceptional organization of multiple connection points while maintaining secure wire termination
- Zoptymalizowany system montażu: Built-in 49.5mm spaced mounting holes for secure and standardized installation in control panels
- Kompatybilność ze śrubami M3: Zaprojektowany do pracy ze standardowymi śrubami M3 dla bezpiecznych połączeń w aplikacjach o ograniczonej przestrzeni
- Enhanced Wire Capacity: Accommodates wire gauges from 0.5mm² to 2.5mm², with additional capacity up to 3.5mm² for flexibility in medium-current installations
- Doskonała odporność na temperaturę: Wytrzymuje ciągłą pracę w wysokich temperaturach do 750°C, idealny do zastosowań, w których plastikowe zaciski mogłyby zawieść.
- Doskonała izolacja elektryczna: Materiał ceramiczny zapewnia wyjątkową wytrzymałość dielektryczną i zapobiega upływowi prądu między sąsiednimi obwodami.
- Ognioodporność: Naturalnie ognioodporny materiał eliminuje ryzyko zapłonu lub rozprzestrzeniania się płomienia w krytycznych instalacjach.
- Odporność chemiczna: Odporność na oleje, rozpuszczalniki i większość kwasów, zapewniająca trwałość w trudnych warunkach przemysłowych
- Balanced Design: Optimized 15mm height profile balances robustness with space efficiency
Specyfikacja techniczna
SPECYFIKACJA | MODEL | DŁUGOŚĆ | SZEROKOŚĆ | WYSOKOŚĆ | ZAKRES OKABLOWANIA |
---|---|---|---|---|---|
1 wejście 1 wyjście 10 A | CTB1110 | 19 mm | 10 mm | 15 mm | 0,5-2,5 mm2 |
1 wejście 1 wyjście 30 A | CTB1130 | 18 mm | 14 mm | 18 mm | 0,5-6 mm2 |
2 wejścia 2 wyjścia 10A | CTB2210 | 20,7 mm | 18,9 mm | 13,9 mm | 0,5-2,5 mm2 |
2 wejścia 2 wyjścia 15A | CTB2215 | 28,4 mm | 20,4 mm | 16,3 mm | 0,5-4 mm2 |
2 Wejścia 2 Wyjścia 30A | CTB2230 | 31 mm | 27 mm | 18,9 mm | 1,5-6 mm2 |
2 Wejścia 2 Wyjścia 60A | CTB2260 | 38,7 mm | 31 mm | 22,7 mm | 2,5-16 mm2 |
2 wejścia 2 wyjścia 100A | CTB22100 | 41,1 mm | 30,2 mm | 25,85 mm | 6-25 mm2 |
3 Wejścia 3 Wyjścia 10A | CTB3310 | 31 mm | 20 mm | 14,3 mm | 0,5-2,5 mm2 |
3 Wejścia 3 Wyjścia 15A | CTB3315 | 35,5 mm | 20,3 mm | 20,2 mm | 0,5-4 mm2 |
3 Wejścia 3 Wyjścia 30A | CTB3330 | 46,2 mm | 26,4 mm | 19,2 mm | 1,5-6 mm2 |
4 Wejścia 4 Wyjścia 30A | CTB4430 | 57 mm | 25 mm | 18,8 mm | 1,5-6 mm2 |
5 wejść 5 wyjść 15 A | CTB5515 | 50 mm | 22 mm | 13 mm | 0,5-2,5 mm2 |
6 wejść 6 wyjść 15 A | CTB6615 | 56,6 mm | 21 mm | 13 mm | 0,5-2,5 mm2 |
8 wejść 8 wyjść 15 A | CTB8815 | 68 mm | 21 mm | 13 mm | 0,5-2,5 mm2 |
10 wejść 10 wyjść 15 A | CTB101015 | 88 mm | 18 mm | 15 mm | 0,5-3,5 mm2 |
CTB101015 Detailed Specifications:
- Aktualna ocena: 15A na obwód
- Konfiguracja: Ten-in, Ten-out
- Wymiary: 88mm (L) × 18mm (W) × 15mm (H)
- Zasięg przewodu: 0.5-3.5mm²
- Średnica otworu na przewód: 3 mm
- Materiał obudowy: Ceramika wysokiej częstotliwości
- Materiał przewodnika: Rdzeń miedziany
- Materiał śruby: Cynk pokryty żelazem
- Kompatybilność śrub: Wątek M3
- Rozstaw otworów montażowych: 49.5mm center-to-center
- Kompatybilne typy przewodów: Nadaje się zarówno do przewodów miękkich, jak i twardych
- Maksymalna temperatura pracy: 750°C
- Wytrzymałość dielektryczna: 3kV
- Odporność na izolację: >1000MΩ przy 500VDC
- Rezystancja styków: <0,5 mΩ
- Maksymalny moment obrotowy: 0,6-0,8 N-m
Aplikacje specjalistyczne
The CTB101015 Ceramic Terminal Block is specifically designed for the most demanding high-density applications requiring extensive medium-current circuits with maximum connection flexibility:
- Złożone systemy sterowania: Industrial automation and process control systems requiring extensive parallel connections
- Oprzyrządowanie wielokanałowe: Advanced measurement and monitoring systems with numerous discrete channels
- Rozproszone sieci sterowania: Large-scale industrial control systems with centralized connection of multiple distributed devices
- Multi-Zone Building Management: Commercial building automation systems with comprehensive zone control
- Communications Infrastructure: High-density telecommunications and networking equipment
- Profesjonalne systemy audio/wideo: High-end production and broadcast equipment requiring numerous isolated signal paths
- Badania i rozwój: Laboratory testing apparatus requiring extensive isolated experimental circuits
- Complex Sensing Networks: Industrial monitoring systems with extensive sensor arrays
Wytyczne dotyczące profesjonalnej instalacji
For optimal performance and reliability in high-density multi-circuit applications, follow these specialized installation guidelines:
- Upewnij się, że powierzchnia montażowa jest czysta, płaska i odporna na wysoką temperaturę.
- Utilize the integrated 49.5mm mounting holes for secure attachment to mounting panels
- Implement a comprehensive circuit documentation system before installation to maintain proper identification
- Odizoluj przewody do odpowiedniej długości (zazwyczaj 5-7 mm).
- Przed włożeniem przewodów należy całkowicie poluzować śruby zacisków
- Całkowicie włóż przewód do otworu zacisku
- Dokręć śruby M3 momentem 0,6-0,8 N-m, uważając, aby nie dokręcić ich zbyt mocno.
- Sprawdź poprawność połączenia, delikatnie pociągając za każdy przewód.
- Apply a systematic labeling scheme to identify each circuit for future maintenance
- Zachowaj odpowiedni odstęp wokół bloku zacisków, aby zapewnić prawidłowe odprowadzanie ciepła.
The CTB101015 Advantage: The Ultimate in Connection Flexibility
For the most sophisticated electrical systems requiring extensive connection points, the CTB101015 Ceramic Terminal Block offers the definitive solution in high-density terminal technology. Its unprecedented ten-in, ten-out configuration provides maximum connection capacity while maintaining professional-grade reliability – making it the ultimate choice for complex electrical systems where extensive circuit connections must be accommodated without compromising on connection integrity, thermal stability, or long-term performance.